- Line Regulation of a constant voltage power supply
- The change in the static value of DC output voltage resulting from a change in AC input voltage from low line to high line or from high line to low line.
- Radiated EMI
- Also called radio frequency interference (RFI), EMI is unwanted high frequency energy caused by the noise generators of the adaptors. That portion that is radiated through space is known as radiated EMI. Most radiated EMI measurements are done between 30MHz and 300MHz. See Conducted EMI
- Rated Output Current
- Maximum output current that can be continuously drawn from a converter under specified conditions.
- Redundant Operation
- Parallel configuration of converters used in distributed power system to increase system reliability. Converters may be used in a “N+1” architecture.
- Reference
- The stable voltage, generally a Zener diode, from which the output voltage of a regulated supply is controlled.
- Reflected Ripple Current
- Regulation
- Ability of a converter to maintain an output voltage to within specified limits under varying conditions of input line and output load.
- Remote Error Sensing or Remote Sensing
- A feature found on most power supplies, which, by means of two extra wires between the supply and the load, permits the power supply to achieve its optimum regulation at the load terminals rather than at the power supply output terminals, thus compensating for the IR drop present in the current carrying leads connecting the load to its power supply. The current through the sensing leads is so small that in spite of the resistance of these leads, their voltage drop is negligible.
- Remote Programming
- A feature of most power supplies which permits control of the regulated output current or voltage by means of a remotely varied resistance or voltage.
- Remote Programming Speed
- The time (µsec) required for the output voltage to change from zero volts to within “X” millivolts of the maximum rated output or from the maximum rated output to within “X” millivolts of zero. “X” is specified separately for each model, generally of the same order as the load regulation specification.
- Remote Shutdown
- Resolution
- For an adjustable supply, the smallest change in output voltage that can be realized by the adjustment.
- Return
- The name for the common terminal of the output of a power supply; it carries the return current for the outputs.
- Reverse Voltage Protection
- A feature that prevents damage to internal components if a reverse voltage is inadvertently applied to the input or output terminals.
- Ripple and Noise
- The residual AC component which is superimposed on the DC output of a regulated power supply. Ripple and noise may be specified in terms of its RMS or (preferably) peak-to peak value. When the peak-to-peak value is specified, it should be accompanied by the maximum bandwidth of the measuring instrument, typically DC to 20 MHz. Measuring ripple and noise with an instrument that has insufficient bandwidth may conceal high frequency spikes detrimental to the load.
comments powered by Disqus
Absolute Maximum Ratings Adaptor Aging Ambient Temperature Auto-Parallel or automatic parallel Auto-Series or automatic series
operation Base Plate Temperature Basic Insulation Battery Backup Breakdown Voltage Burn-in CB-Scheme CFM Canadian Standards Association (CSA) Case Case Temperature Common Common Mode Noise Conducted EMI Conduction Cooled Constant Current Power Supply Constant Voltage Power Supply Constant Voltage/Constant Current
(CV/CC) with automatic crossover Constant Voltage/Current Limiting
(CV/CL) with automatic crossover Convection Cooled Cross Regulation Crowbar Current Limit Knee Current Limiting Derating Dielectric Dielectric Withstand Voltage Differential Mode Noise Drift Dynamic Load Dynamic Response EMI Filter Efficiency Electromagnetic Interference (EMI) Electrostatic Discharge (ESD) Electrostatic Shield Enclosure Equivalent Series Inductance(ESL) Equivalent Series Resistance (ESR) Failure Mode Faraday Shield Fault Mode Current Federal Communications Commission
(FCC) Floating Output Foldback Current Limiting Forced Air Cooling Free Convection Front End Full Load Ground Ground Loop Heat Sink Hi-Pot Test High Line Hold-Up Time Hot Plug-In Input Current Input Line Filter Input Surge Current Input Transient Input Voltage Range Inrush Current Inrush Current Limiting Insulation Insulation Resistance Internal Power Dissipation International Electrotechnical
Commission (IEC) Isolation Isolation Voltage Leakage Current Life Test Line Regulation of a constant current
power supply Line Regulation of a constant voltage
power supply Linear Regulation Load Load Decoupling Load Regulation of a Constant Current
Power Supply Load Regulation of a Constant Voltage
Power Supply Local Sensing Logic Inhibit/Enable Long Term Stability Low Line Master/Slave Operation Maximum Load Mean Time Between Failure (MTBF) Minimum Load Minimum Operating Temperature N+1 Redundancy No Load Voltage Noise Nominal Value OTP: Over Temperature Protection Open Frame Open-Circuit Voltage Operating Temperature Range Output Current Limiting Output Impedence of a power supply Output Voltage Output Voltage Accuracy Output Voltage Range Overload Protection Overshoot Overvoltage Protection (OVP) Parallel Operation Periodic and Random Deviation (PARD) Pi Filter Polarity Post Regulation Power Density Power Factor Correction (PFC) Power Good Power Rating Pre-Regulation Primary Circuit Programmable Power Supply Radiated EMI Rated Output Current Redundant Operation Reference Reflected Ripple Current Regulation Remote Error Sensing or Remote Sensing Remote Programming Remote Programming Speed Remote Shutdown Resolution Return Reverse Voltage Protection Ripple and Noise SMBus Secondary Circuit Sense Line Series Operation Series Regulator Short Circuit Protection Shunt Regulator Six-Sided Shielding Soft Start Split Bobbin Winding Stability Standby Current Step Change Storage Temperature Range Technischer Uberwachungs-Verein
(TUV) Temperature Coefficient Temperature Range Thermal Conductivity Thermal Gasket Thermal Joint Compound Thermal Protection Thermal Resistance Thermal Resistivity Thermal Shutdown Three-Terminal Regulator Topology Tracking Transient Transient Recovery Time Under Voltage Lock Out (UVLO) Undershoot Underwriters Laboratories (UL) UninterruptiblePower Supply (UPS) Verband Deutsher Elektrotechniker