GT-G3061P3000VV-X.X-C Enclosed-Metal ICT/ITE Power Supply
GT-G3061P3000VV-X.X-C | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
GT-G3061P3000VV-X.X-C, ICT/ITE Power Supply, Enclosed-Metal, Programmable Medical Power Supply, , Input Rating: 90 ~ 264VAC, 127 ~ 370VDC (47 ~ 63Hz), 3 Positon Terminal Block, Output Rating: 3000 Watts, Power rating with convection cooling (W) , 12-60V in 0.1V increments, Approvals: China RoHS; Class I; cULus; RoHS; VCCI; WEEE; CE; Ukraine; | |||||||||||||||||||||||||||||||||||||||||
Information | |||||||||||||||||||||||||||||||||||||||||
Model Number | GT-G3061P3000VV-X.X-C | ||||||||||||||||||||||||||||||||||||||||
Agency Documents | http://www.globtek.info/certs/GT-G3061PWWWWVV-X.X-C/ | ||||||||||||||||||||||||||||||||||||||||
CE EC-Declaration for Medical | Contact GlobTek for more information | ||||||||||||||||||||||||||||||||||||||||
CE EC-Declaration for Industrial/Commercial/ITE | https://cs.globtek.info/ec_declaration?id=a0Oa000000MiUkHEAV | ||||||||||||||||||||||||||||||||||||||||
CE EC-Declaration for Household | Contact GlobTek for more information | ||||||||||||||||||||||||||||||||||||||||
UKCA-Declaration for Medical | Contact GlobTek for more information | ||||||||||||||||||||||||||||||||||||||||
UKCA-Declaration for Industrial/Commercial/ITE | https://cs.globtek.info/ukca_declaration?id=a0Oa000000MiUkHEAV | ||||||||||||||||||||||||||||||||||||||||
UKCA-Declaration for Household | Contact GlobTek for more information | ||||||||||||||||||||||||||||||||||||||||
Morocco SDoC Declaration | https://cs.globtek.info/Morocco_SDoC_Declaration?id=a0Oa000000MiUkHEAV | ||||||||||||||||||||||||||||||||||||||||
RoHS/RoHS3 Declaration | https://www.globtek.com/pdf/rohs_cert/a0Oa000000MiUkHEAV | ||||||||||||||||||||||||||||||||||||||||
Prop 65 Statement | https://www.globtek.com/r2/PH7CNf | ||||||||||||||||||||||||||||||||||||||||
REACH Declaration | https://www.globtek.com/r2/eM2co8 | ||||||||||||||||||||||||||||||||||||||||
Conflict Minerals Declaration | https://www.globtek.com/r2/vZY8R5 | ||||||||||||||||||||||||||||||||||||||||
Model Parameters | |||||||||||||||||||||||||||||||||||||||||
Type | Enclosed-Metal | ||||||||||||||||||||||||||||||||||||||||
Technology | Programmable Medical Power Supply | ||||||||||||||||||||||||||||||||||||||||
Category | ICT/ITE Power Supply | ||||||||||||||||||||||||||||||||||||||||
Input Voltage Range (V) | 90 ~ 264VAC, 127 ~ 370VDC (47 ~ 63Hz) | ||||||||||||||||||||||||||||||||||||||||
Max Input Current (A) | 36A / 115VAC, 18A / 230VAC | ||||||||||||||||||||||||||||||||||||||||
Max Output Power Rating (W) | 3000 | ||||||||||||||||||||||||||||||||||||||||
Output Voltage Range (V) | 12-60 | ||||||||||||||||||||||||||||||||||||||||
Efficiency | N/A | ||||||||||||||||||||||||||||||||||||||||
Ingress Protection | IPX0 | ||||||||||||||||||||||||||||||||||||||||
Size (mm) | 366 x127 x127 | ||||||||||||||||||||||||||||||||||||||||
Enclosure | |||||||||||||||||||||||||||||||||||||||||
Rating Table | |||||||||||||||||||||||||||||||||||||||||
* (Final ordering #/Part No to be defined) | |||||||||||||||||||||||||||||||||||||||||
Specifications | |||||||||||||||||||||||||||||||||||||||||
Features: Universal AC input / Full range Programmable output Voltage (0% ~ 105%) Programmable output Current (0% ~ 105%) Forced current sharing at parallel operation Constant current limit Selectable +5V / 0.5A or +9V / 0.3A auxiliary output Global control via RS232 Remote setting multiple PSU via RS232, RS485 & I²C Power OK signal Remote ON / OFF, Remote sense function Protection: OVP, OLP, OTP, SCP, Fan failure Output DC Voltage Range: 12V, 15V, 24V, 30V, 36V, 48V, 60V Rated Current: 250A 200A 125A 100A 83.5A 62.5A 50A Current Range: 0~250A 0~200A 0~125A 0 ~ 100A 0 ~ 83.5A 0 ~ 62.5A 0 ~ 50A Rated Power: 3000W 3000W 3000W 3000W 3006W 3000W 3000W Ripple & Noise (Max.)v Note.2 150mVp-p 150mVp-p 200mVp-p 200mVp-p 200mVp-p 200mVp-p 300mVp-p Voltage Adj. Range: ±5.0% Typical adjustment by potentiometer. (VR1) Voltage Tolerance: ±2.0% Line Regulation: ±1.0% Load Regulation: ±1.0% Setup, Rise Time: 800ms, 50ms at full load Hold Up Time (Typ.): 14ms / 230VAC at full load Input Voltage Range: 90 ~ 264VAC, 127 ~ 370VDC Frequency Range: 47 ~ 63Hz (Refer to de-rating curve) Power Factor (Typ.): 0.95 / 230VAC, 0.98 / 115VAC at full load Efficiency (Typ.): 89%, 90%, 91%, 91%, 92%, 92%, 93% AC Current (Typ.): 36A / 115VAC (3000W), 18A / 230VAC (3000W) Inrush Current (Typ.): 60A / 115VAC, 90A / 230VAC Leakage Current: < 2.5mA / 240VAC Protection Over Load: 105% rated output power Protection type: Constant current limit Over Voltage: Variable OVP, 120 ± 7% Vout. Refer to VCI VS OVP curve. Protection type: Latch-style (Recovery after reset AC power ON or inhibit) Over Temperature: 85 ±5°C detect on heat sink of primary and secondary side Protection type: Auto recovery after temperature goes down Function Auxiliary Power: Selectable +5V / 0.5A or +9V / 0.3A auxiliary output Remote ON / OFF Control: By external switch Power OK Signal: Open drain signal low when PSU turns on, Max. sink current: 20mA, Max. drain voltage: 40V. Output Voltage Trim: Adjustment of output voltage is between 0 ~ 105% of rated output Output Current Trim: Adjustment of output current is between 0 ~ 105% of rated output Parallel (Current Sharing): Note.5 Please refer to page 5 Environment Working Temp.: -25 ~ +60°C (Refer to de-rating curve) Working Humidityv 20 ~ 90% RH non-condensing Storage Temp. & Humidityv -40 ~ +85°C, 10 ~ 95% RH Temp. Coefficient: ±0.02% / °C (0 ~ 50°C) Vibration: 10 ~ 500Hz, 2G 10min. / 1cycle, period for 60min. each along X, Y, Z axes Compliance to IEC 68-2-6, IEC 68-2-64 Safety & EMC Safety Standardsv Certified UL 60950-1; EN 60950-1 Withstand Voltage: I/P-O/P: 3KVAC (4242VDC), I/P-FG: 1.5KVAC (2121VDC), O/P-FG: 0.5KVAC (707VDC) Isolation Resistance: I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC EMI Conduction & Radiation: Certified EN 55022; EN 61204-3; EN 61000-6-3 Harmonic: Current Certified EN 61000-3-2; EN 61000-3-3 EMS Immunity: Certified EN 55024; EN 61204-3; EN 61000-6-1; IEC 61000-4-2, 3, 4, 5, 6, 8, 11 Others Coolingv Load and temperature control fan Dimension (WxHxD)v 366x127x127mm Packingv 5.25kg; 4pcs / 21kg / 1.86CUFT Note 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor. 3. Tolerance: includes setup time tolerance, line regulation and load regulation. 4. De-rating may apply in low input voltage. Please check the de-rating curve for more details. 5. In parallel connection only one unit will operate if the total output load is less than 5% of the rated power. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 7. This test is done without enclosure. | |||||||||||||||||||||||||||||||||||||||||
Derating Curve | |||||||||||||||||||||||||||||||||||||||||
Qty (ea.)/Carton | 4 | ||||||||||||||||||||||||||||||||||||||||
Individual Box/Gift Box Size (mm) | 380*130*130 | ||||||||||||||||||||||||||||||||||||||||
Individual Box/Gift Box Color | White | ||||||||||||||||||||||||||||||||||||||||
Master Carton Size (mm) | TBD | ||||||||||||||||||||||||||||||||||||||||
Gross Weight (kg) | 21.0 | ||||||||||||||||||||||||||||||||||||||||
Label Width (mm) | 110.0 | ||||||||||||||||||||||||||||||||||||||||
Label Height (mm) | 30.0 | ||||||||||||||||||||||||||||||||||||||||
Input Configuration | |||||||||||||||||||||||||||||||||||||||||
Description | 3 Positon Terminal Block Optional Input Wiring Kits are available:
| ||||||||||||||||||||||||||||||||||||||||
Approvals | |||||||||||||||||||||||||||||||||||||||||
Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice. Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation. | |||||||||||||||||||||||||||||||||||||||||
|