Request Information Download PDF Configure Output Connector
GTM43004P-WWVV-x.x-T2 GTM43004P-WWVV-x.x-T2
Information
Model NumberGTM43004P-WWVV-x.x-T2
DescriptionGTM43004P-WWVV-x.x-T2, ITE / Medical Power Supply, Desktop/External, Regulated Switchmode AC-DC, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C8 AC Inlet connector, Class II, Non-Earth Ground (aka "Figure-8"), Output Rating: 120 Watts, 5-48V in 0.1V increments, Approvals: CE CB cETLus 60601-1 3rd China RoHS Double Insulation GOST-R Level V PSE RoHS 2 S-Mark IEC/EN 60601-1 Ukraine WEEE NEMKO EN/IEC 60335-1 cETLus ES60601 cETLus IP40 VCCI CB EN/IEC 60335-1 CCC
Agency Documentshttp://www.globtek.info/certs/GTM43004P/
CE EC-Declaration for Medicalhttp://globtek.force.com/models/ec_declaration?id=a0Oa000000HSeFwEAL
CE EC-Declaration for Industrial/Commercial/ITEhttp://globtek.force.com/models/ec_declaration?id=a0Oa000000HSeFwEAL
RoHS/RoHS2 Declarationhttp://www.globtek.com/pdf/rohs_cert/a0Oa000000HSeFwEAL
REACH Declarationhttp://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttp://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeDesktop/External
TechnologyRegulated Switchmode AC-DC
CategoryITE / Medical Power Supply
Input Voltage100-240V~, 50-60 Hz
I/P Amps (A)2.0A
Wattage (W)120
Vout Range (V)5-48
EfficiencyV
Ingress Protection
Size (mm)172.5*72.2*42.0
EnclosureUser-added image
Rating Table
Model Number VoltageAmps (A)Watts (W) RFQ
GTM43004P-508.9-3.9-T2 51050 RFQ
GTM43004P-608.9-2.9-T2 61060 RFQ
GTM43004P-9016-7.0-T2 91090 RFQ
GTM43004P-12016-4.0-T2 1210120 RFQ
GTM43004P-9016-4.0-T2 127.590 RFQ
GTM43004P-12016-1.0-T2 158120 RFQ
GTM43004P-12024-6.0-T2 186.66119.88 RFQ
GTM43004P-12024-5.0-T2 196.31119.89 RFQ
GTM43004P-12024-4.0-T2 206120 RFQ
GTM43004P-12024-T2 245120 RFQ
GTM43004P-12035-5.0-T2 304120 RFQ
GTM43004P-12048-12.0-T2 363.33119.88 RFQ
GTM43004P-12048-T3 482.5120 RFQ
SpecificationsA) ELECTRICAL SPECIFICATIONS:
01. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac
02. Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz
03. Output Regulation: +/- 5% measured at the output connector
04. Line Voltage Regulation: +/- 1% typical measured at the output connector
05. Output Ripple (Vp-p): +/-1% or 200 mV whichever is greater, measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with 47 uf electrolytic capacitor connected at the end of the output connector at nominal line
06. Turn-ON/OFF Overshoot: 10% maximum, 1 mS typical recovery time for 25% step load
07. Turn-ON Delay: 3000 mS, maximum @ full load, nominal line
08. Hold-Up Time: 10 mS typical @ nominal input voltage and full load
09. Inrush Current: 40A typical 115VAC input and 60A typical at 230VAC input
11. Switching Frequency: 100 KHz typical

B) PROTECTION
01. Over-Voltage: AC cycling required to reset output
02. Short Circuit: AC cycling required to reset output
03. Input Protection: Input line fusing

C) SAFETY
1. Dielectric Withstand Voltage: 5656 Vdc from primary to secondary
2. Earth Leakage Current: N/A for Class II units, there is no PE Ground pin, so Earth Leakage current is not measured
3. Touch Current: Maximum allowed values: 100uA NC(Normal condition) 500uA SFC(single fault condition)
4. Means of Protection: 2 x MOPP
5. Primary to Secondary Bridging Capacitor: (2) * Y1 type capacitors in series
6. ROHS 2: Complies with EU 2011/65/EU and China SJ/T 11363-2006

D) OTHER:
01. MTBF: 200,000 Hours @ 25°C ambient temperature
02. Operating Temperature: 0°C to 40°C ambient temperature
03. Humidity: 0% to 90% relative humidity
04. Storage Temperature: -10°C to 80°C
05. Cooling: Convection

E) ENCLOSURE
01. Housing: High impact plastic, 94V0 polycarbonate, non-vented
02. Size: 172.5*72.2*42.0 mm +/-1.0 mm
03. Markings: Label and/or Pad Printed and/or Molded in the case
04. GREEN LED to indicate power ON
Derating Curve
Qty (ea.)/Carton20
Individual Box/Gift Box Size (mm)Cell Packaging
Individual Box/Gift Box ColorWhite
Master Carton Size (mm)461 x 460 x 192
Gross Weight (kg)15.6
Label Width (mm)39.5
Label Height (mm)99.5
Input Configuration
DescriptionIEC 60320/C8 AC Inlet connector, Class II, Non-Earth Ground (aka "Figure-8")User-added image

Mates with IEC 60320/C7 Plug

Standard International IEC 320/C7 Cordsets

Below are standard cordsets which are "not included" (unless stated above); these may be purchased separately or packaged with the power supply. Please contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material.
 

2 Conductors (No Ground) IEC 320/C7 (Figure "8")

4511116F703A(R)

N. American

NEMA 1-15P

IEC 320/C7

1830

6

5014112M703A(R)

Australian

AS 3112

IEC 320/C7

2000

7

4533501M8703(R)

China

GB 2099.1

IEC 320/C7

1830

6

2074112M703A(R)

European

CEE 7/16

IEC 320/C7

2000

7

451J3401M8703(R)

Japan

JIS 8303

IEC 320/C7

1830

6

6104112M703A(R)

UK

BS1363

IEC 320/C7

2000

7

Output Configuration
Common output connector options:
Click to add to your request.






L Type (Coaxial 5.5x2.5mm plug) C Type (Coaxial 5.5x2.1mm plug) K Type (Coaxial 3.5x1.3mm plug) LL Type (5.5x2.5mm Locking 760k type) CL Type (5.5x2.1mm Locking S761k type) Magnetic Connector





YL3 Type (KPPX-3P) YL4 Type (KPPX-4P) EJ1/2/3/4/5 (EIAJ RC-5320A type connectors) MSB Type (Micro USB) Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals
LogoDescription
User-added imageBook 60335 up to 36 Volts
User-added image60601-1 3rd Operating Instructions
No Logo ApplicableCB report IEC 60601-1: 2005 + CORR. 1 (2006) + CORR. 2 (2007) and or EN 60601-1:2006 3rd Edition including 2MOOP requirements

No Logo Applicable

CB to 60335-1 5th Edition (Safety of Household and Similar Electrical Appliances, Part 1: General Requirements) CB Report/ Certificate IEC 60335-1:2010 Up to 36 volts only
CCC Alt Less Than 2000M No HumidityCCC to GB4943.1-2011 GB9254-2008 GB17625.1-2012 GTM43004P
User-added image  CE Mark: tested to comply with EN 60601-1-2:2007 Medical electrical equipment Part 1-2: - Mark is on the label or Molded in the case
Conforms to ANSI/AAMI ES 60601-1:2005
Cert.to CAN/CSA Std. C22.2
 
cETLus ANSI_AAMI ES60601-1_2005
User-added imageConforms to ANSI/UL Std. 60950-1 2nd Edition Cert. to CAN/CSA Std.C22.2 NO.60950-1 2nd Edition
User-added image
 
cETLus-Cert-4007497 ANSI/AAMI ES60601-1:2005 with AMD C1: 2009, AMD C2: 2010 and CAN/CSA-C22.2 No. 60601-1 2008 with COR 2:2011+ANSI/AAMI HA60601-1-11 Ed:1 for T2 only
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
User-added image

Double Insulation - Mark is on the label or Molded in the case
User-added image
Fuse 60335 T4.0A 250VAC Up to 36 volts
User-added image
 
GOST-R mark for Russia(Document: http://www.globtek.com/html/iso_certificates/GT_GOST-R.pdf). 03/15/2015. Due to lack of demand, GlobTek will not be renewing it's GOST certification. Please contact your sales engineer for pricing on EAC.
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
IP40Ingress Protection: IP40 to IEC60529:2001 Protection against granular foreign bodies
 User-added image

Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
User-added imageNEMKO IEC/EN 60335-1 (Safety of Household and Similar Electrical Appliances, Part 1: General Requirements) up to 36 Volts
User-added imageJAPAN TUV Rheinland-PSE GlobTek Inc to J60950-1(H26) , J55022(H22),J3000(H25).Please follow the procedure listed in the following link for proper import to Japan: http://en.globtek.com/importing-to-japan.php.
RoHS 2RoHS 2: Complies with EU 2011/65/EU and CHINA SJ/T 11363-2006 http://www.ce-mark.com/Rohs%20final.pdf
User-added imageSemko S-Mark-Cert-EN60601-1 3rd Edition (http://www.intertek.com/marks/s/)
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products
SKUVolts OutCurrent Out (Amps)Connector
168723127.5Female Barrel 5.5 * 2.5 * 11mm No internal Spring Clip nor Locking Notch or Equal
3579691210.04 PIN LOCKING CONNECTOR, KYCON KPPX-4P OR EQUIVALENT
3449671210.04 PIN LOCKING CONNECTOR, KYCON KPPX-4P OR EQUIVALENT
169715127.5Singatron 2DP1505-000111 or 2DP-74P06C2901T0002 with ID Resistor
371701127.5Strip only 0.25" insulation from Black conductor, 0.125" insulation from white conductor
168704167.5Female Barrel 5.5*2.5*12mm No internal Spring Clip nor Locking Notch or Equal
180734196.310/peak 7.4A@1sec3 Pin Kycon KPP-3 Locking Plug or Equal
169356196.310/peak 7.4A@1sec4 Pin Kycon Locking Plug or Equal
340348196.31Female Barrel 5.5 * 2.5 * 11mm No internal Spring Clip nor Locking Notch or Equal
241870196.31Female Barrel 5.5 * 2.5 * 11mm No internal Spring Clip nor Locking Notch or Equal
180742196.31CONN INLINE PLUG 3PIN CRIMP
273154196.315-PIN ODU MINI-SNAP PC S12A1G-P05LPH0-4500 connector no equivalent, color: grey
168724245Female Barrel 5.5 * 2.5 * 11mm No internal Spring Clip nor Locking Notch or Equal
183606245Consigned plug
1783272454 Pin 180 degree DIN Plug or Equal
175393246.254 Pin Kycon Locking Plug or Equal
1864622454 Pin Kycon Locking Plug or Equal
171680284.28Female Barrel Right Angle 6.5*3.0*13.5mm with internal Spring Clip and Locking Notch or Equal
News Releases
TitleWeb Link
Medical (60601-1) Power Supply AC Adapter Certified to ANSI/AAMI ES60601-1 for the United States and Canada is rated up to 120W output with 12-48V output options., Model Series GTM43004P-T2 –T3(A) –F .http://en.globtek.com/news.php/medical-60601-1-power-supply-ac-adapter-certified-to-ansi-aami-es60601-1-for-the-united-states-and-canada-is-rated-up-to-120w-output-with-12-48v-output-options-model-series-gtm43004p-t2-t3a-f#.UcGzVPmkqoe
Medical (60601-1) Power Supply AC Adapter Certified to IEC 60601-1: 2005 + CORR. 1 (2006) + CORR. 2 (2007) and EN 60601-1:2006 + A11:2011 via CB Report a is rated up to 120W output with 12-48V output options. Model Series GTM43004P-T2 –T3(A)http://en.globtek.com/news.php/medical-60601-1-power-supply-ac-adapter-certified-to-iec-60601-1-2005-corr-1-2006-corr-2-2007-and-en-60601-12006-a112011-via-cb-report-a-is-rated-up-to-120w-output-with-12-48v-output-options-model-series-gtm43004p-t2-t3a
Internal Open Frame Medical (60601-1) Power Supply AC Adapter Certified to IEC 60601-1: 2005 + CORR. 1 (2006) + CORR. 2 (2007) and EN 60601-1:2006 + A11:2011 via CB Report a is rated up to 120W output with 12-48V output options. Model Series GTM43004P-Fhttp://en.globtek.com/news.php/internal-open-frame-medical-60601-1-power-supply-ac-adapter-certified-to-iec-60601-1-2005-corr-1-2006-corr-2-2007-and-en-60601-12006-a112011-via-cb-report-a-is-rated-up-to-120w-output-with-12-48v-output-options-model-series-
Medical (60601-1) External Freestanding Power Supply AC Adapter Certified to ANSI/AAMI ES60601-1 for the United States and Canada is rated up to 120W output with 12-48V output options., Model Series GTM43004P-T2 –T3(A) –Fhttp://en.globtek.com/news.php/medical-60601-1-external-freestanding-power-supply-ac-adapter-certified-to-ansiaami-es60601-1-for-the-united-states-and-canada-is-rated-up-to-120w-output-with-12-48v-output-options-model-series-gtm43004p-t2-t3a-f#.Uk8I1BA6Da
60335-1 CB Certificate IEC 60335-1:2010 (Fifth Edition) 60335-1 CB report IEC 60335-1:2010 (Fifth Edition) EN 60335-1: 2012)

Request Info