Request Information Download PDF
GT-G3061P3000VV-X.X-C GT-G3061P3000VV-X.X-C
3000W Single Output Power Supply with active PFC. High Efficiency up to 93%. Power OK signal (Power Good, Logic Low). Protection: OVP, OLP, OTP, Fan failure.
Information
Model NumberGT-G3061P3000VV-X.X-C
DescriptionGT-G3061P3000VV-X.X-C, ITE Power Supply, Enclosed-Metal, Programmable Medical Power Supply, , Input Rating: 90 ~ 264VAC, 127 ~ 370VDC (47 ~ 63Hz), 3 Positon Terminal Block, Output Rating: 3000 Watts, 12-60V in 0.1V increments, Approvals: China RoHS Class I cUL RoHS 2 VCCI WEEE CE Ukraine
Agency Documentshttp://www.globtek.info/certs/GT-G3061PWWWWVV-X.X-C/
CE EC-Declaration for MedicalContact GlobTek for more information
CE EC-Declaration for Industrial/Commercial/ITEhttp://globtek.force.com/models/ec_declaration?id=a0Oa000000MiUkHEAV
RoHS/RoHS2 Declarationhttp://www.globtek.com/pdf/rohs_cert/a0Oa000000MiUkHEAV
REACH Declarationhttp://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttp://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeEnclosed-Metal
TechnologyProgrammable Medical Power Supply
CategoryITE Power Supply
Input Voltage90 ~ 264VAC, 127 ~ 370VDC (47 ~ 63Hz)
I/P Amps (A)36A / 115VAC, 18A / 230VAC
Wattage (W)3000
Vout Range (V)12-60
EfficiencyN/A
Ingress ProtectionIPX0
Size (mm)366 x127 x127
EnclosureUser-added image

User-added image

User-added image
User-added image
User-added image
User-added image
User-added image
User-added image
User-added image
User-added image

User-added image
 
Rating Table
Model Number VoltageAmps (A)Watts (W) RFQ
GT-G3061P300012-C 122503000 RFQ
GT-G3061P300015-C 152003000 RFQ
GT-G3061P300024-C 241253000 RFQ
GT-G3061P300030-C 301003000 RFQ
GT-G3061P300036-C 3683.53006 RFQ
GT-G3061P300048-C 4862.53000 RFQ
GT-G3061P300060-C 60503000 RFQ
SpecificationsFeatures:
Universal AC input / Full range
Programmable output Voltage (0% ~ 105%)
Programmable output Current (0% ~ 105%)
Forced current sharing at parallel operation
Constant current limit
Selectable +5V / 0.5A or +9V / 0.3A auxiliary output
Global control via RS232
Remote setting multiple PSU via RS232, RS485 & I²C
Power OK signal
Remote ON / OFF, Remote sense function
Protection: OVP, OLP, OTP, SCP, Fan failure

Output
DC Voltage Range: 12V, 15V, 24V, 30V, 36V, 48V, 60V
Rated Current: 250A 200A 125A 100A 83.5A 62.5A 50A
Current Range: 0~250A 0~200A 0~125A 0 ~ 100A 0 ~ 83.5A 0 ~ 62.5A 0 ~ 50A
Rated Power: 3000W 3000W 3000W 3000W 3006W 3000W 3000W
Ripple & Noise (Max.)v Note.2 150mVp-p 150mVp-p 200mVp-p 200mVp-p 200mVp-p 200mVp-p 300mVp-p
Voltage Adj. Range: ±5.0% Typical adjustment by potentiometer. (VR1)
Voltage Tolerance: ±2.0%
Line Regulation: ±1.0%
Load Regulation: ±1.0%
Setup, Rise Time: 800ms, 50ms at full load
Hold Up Time (Typ.): 14ms / 230VAC at full load

Input
Voltage Range: 90 ~ 264VAC, 127 ~ 370VDC
Frequency Range: 47 ~ 63Hz (Refer to de-rating curve)
Power Factor (Typ.): 0.95 / 230VAC, 0.98 / 115VAC at full load
Efficiency (Typ.): 89%, 90%, 91%, 91%, 92%, 92%, 93%
AC Current (Typ.): 36A / 115VAC (3000W), 18A / 230VAC (3000W)
Inrush Current (Typ.): 60A / 115VAC, 90A / 230VAC
Leakage Current: < 2.5mA / 240VAC

Protection

Over Load: 105% rated output power
Protection type: Constant current limit

Over Voltage: Variable OVP, 120 ± 7% Vout. Refer to VCI VS OVP curve.
Protection type: Latch-style (Recovery after reset AC power ON or inhibit)

Over Temperature: 85 ±5°C detect on heat sink of primary and secondary side
Protection type: Auto recovery after temperature goes down

Function
Auxiliary Power: Selectable +5V / 0.5A or +9V / 0.3A auxiliary output
Remote ON / OFF Control: By external switch
Power OK Signal: Open drain signal low when PSU turns on, Max. sink current: 20mA, Max. drain voltage: 40V.
Output Voltage Trim: Adjustment of output voltage is between 0 ~ 105% of rated output
Output Current Trim: Adjustment of output current is between 0 ~ 105% of rated output
Parallel (Current Sharing): Note.5 Please refer to page 5

Environment
Working Temp.: -25 ~ +60°C (Refer to de-rating curve)
Working Humidityv 20 ~ 90% RH non-condensing
Storage Temp. & Humidityv -40 ~ +85°C, 10 ~ 95% RH
Temp. Coefficient: ±0.02% / °C (0 ~ 50°C)
Vibration: 10 ~ 500Hz, 2G 10min. / 1cycle, period for 60min. each along X, Y, Z axes Compliance to IEC 68-2-6, IEC 68-2-64

Safety & EMC
Safety Standardsv Certified UL 60950-1; EN 60950-1
Withstand Voltage: I/P-O/P: 3KVAC (4242VDC), I/P-FG: 1.5KVAC (2121VDC), O/P-FG: 0.5KVAC (707VDC)
Isolation Resistance: I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC
EMI Conduction & Radiation: Certified EN 55022; EN 61204-3; EN 61000-6-3
Harmonic: Current Certified EN 61000-3-2; EN 61000-3-3
EMS Immunity: Certified EN 55024; EN 61204-3; EN 61000-6-1; IEC 61000-4-2, 3, 4, 5, 6, 8, 11

Others
Coolingv Load and temperature control fan
Dimension (WxHxD)v 366x127x127mm
Packingv 5.25kg; 4pcs / 21kg / 1.86CUFT

Note
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor.
3. Tolerance: includes setup time tolerance, line regulation and load regulation.
4. De-rating may apply in low input voltage. Please check the de-rating curve for more details.
5. In parallel connection only one unit will operate if the total output load is less than 5% of the rated power.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
7. This test is done without enclosure.
Derating CurveUser-added image





 
Qty (ea.)/Carton4
Individual Box/Gift Box Size (mm)380*130*130
Individual Box/Gift Box ColorWhite
Master Carton Size (mm)TBD
Gross Weight (kg)21.0
Label Width (mm)110.0
Label Height (mm)30.0
Input Configuration
Description3 Positon Terminal Block
Approvals
LogoDescription
User-added imageAttention Mark / Refer to operating manual for operating and service instructions
User-added image  CE Certification
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
User-added image
Class I Earth Ground
User-added imageUL60950-1, cULus to UL 60950-1 E170507
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
RoHS 2RoHS 2: Complies with EU 2011/65/EU and CHINA SJ/T 11363-2006 http://www.ce-mark.com/Rohs%20final.pdf
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products
SKUVolts OutCurrent Out (Amps)Connector
2418674862.5(1) Position Terminal Block

Request Info