Request Information Download PDF
GT-G3065P1500VV-X.X-C GT-G3065P1500VV-X.X-C
Information
Model NumberGT-G3065P1500VV-X.X-C
DescriptionGT-G3065P1500VV-X.X-C, ITE Power Supply, Enclosed-Metal, Single Output Power supply, , Input Rating: 90 ~ 264VAC, 127 ~ 370VDC (47 ~ 63Hz), 3 Positon Terminal Block, Output Rating: 1500 Watts, 12-48V in 0.1V increments, Approvals: CE GOST-R Ukraine WEEE China RoHS cUL VCCI RoHS 2 Class I PSE
Agency Documentshttp://www.globtek.info/certs/GT-G3065PWWWWVV-X.X-C/
CE EC-Declaration for MedicalContact GlobTek for more information
CE EC-Declaration for Industrial/Commercial/ITEhttp://globtek.force.com/models/ec_declaration?id=a0Oa000000MEPKSEA5
RoHS/RoHS2 Declarationhttp://www.globtek.com/pdf/rohs_cert/a0Oa000000MEPKSEA5
REACH Declarationhttp://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttp://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeEnclosed-Metal
TechnologySingle Output Power supply
CategoryITE Power Supply
Input Voltage90 ~ 264VAC, 127 ~ 370VDC (47 ~ 63Hz)
I/P Amps (A)18A / 115VAC, 9A / 230VAC
Wattage (W)1500
Vout Range (V)12-48
EfficiencyN/A
Ingress ProtectionIPX0
Size (mm)127x63.5x280
EnclosureUser-added image
User-added image

User-added image
User-added image
User-added image
User-added image
User-added image
 
Rating Table
Model Number VoltageAmps (A)Watts (W) RFQ
GT-G3065P150012-C 121251500 RFQ
GT-G3065P150015-C 151001500 RFQ
GT-G3065P150024-C 2462.51500 RFQ
GT-G3065P150027-C 2755.51498.5 RFQ
GT-G3065P150048-C 4831.31502.4 RFQ
SpecificationsFeatures:
Universal AC input / Full range Programmable output Voltage (30% ~ 105%) Programmable output Current (40% ~ 105%)
+5V / 0.5A auxiliary output
High power density 10.8w / in3
Forced current sharing at parallel operation
Power OK signal
Remote ON / OFF, Remote sense function
Protection: OVP, OLP, OTP, SCP, Fan failure


ELECTRICAL SPECIFICATIONS:
Output
DC Voltage Range: 12V 15V 24V 27V 48V
Rated Current: 125A 100A 62.5A 55.5A 31.3A
Current Range: 0~125A 0~100A 0~62.5A 0~55.5A 0~31.3A
Rated Power: 1500W 1500W 1500W 1500W 1500W
Ripple & Noise (Max.): Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p
Voltage Adj. Range: ±5.0% Typical adjustment by potentiometer. (VR1)
Voltage Tolerance: Note.3 ±1.0%
Line Regulation: ±0.5%
Load Regulation: ±0.5%
Setup, Rise Time: 800ms, 200ms at full load
Hold Up Time (Typ.): 16ms / 230VAC at full load

Input
Voltage Range: Note.4 90 ~ 264VAC, 127 ~ 370VDC
Frequency Range: 47 ~ 63Hz
Power Factor (Typ.): 0.98 / 230VAC, 0.99 / 115VAC at full load
Efficiency (Typ.): 87% 88% 89% 89% 90%
AC Current (Typ.): 18A / 115VAC, 9A / 230VAC
Inrush Current (Typ.)v 30A / 115VAC, 45A / 230VAC
Leakage Curren:t < 2.5mA / 240VAC

Protection
Over Load: 105 ~ 110% rated output power.Protection type: Constant current limit, Latch-style (Recovery after reset AC power ON or inhibit)
Over Voltage: Variable OVP, 120 ±5% Vout. Protection type: Latch-style (Recovery after reset AC power ON or inhibit)
Over Temperature: 80 ±5°C.Protection type: Shut down o/p voltage (Auto recovery after temperature goes down)

Function
Auxiliary Power: 5V / 0.5A (±3%)
Remote ON / OFF Control: External switch or NPN Transistor to turn ON / OFF
Power OK Signal: Open drain signal low when PSU turns on, Max. sink current: 20mA, Max. drain voltage: 40V.
Output Voltage Trim: Adjustment of output voltage is between 30 ~ 100% of rated output
Output Current Trimv Adjustment of output current is between 40 ~ 105% of rated output
Parallel (Current Sharing): Please refer to function

Environment
Working Temp.: -25 ~ +60°C (Refer to output load de-rating curve)
Working Humidity: 20 ~ 90% RH non-condensing
Storage Temp. & Humidityv -40 ~ +85°C, 10 ~ 95% RH
Temp. Coefficient: ±0.02% / °C (0 ~ 50°C)
Vibration: 110 ~ 500Hz, 5G 10min. / 1cycle, period for 60min. each along X, Y, Z axes Compliance to IEC 60068-2-6-2007

Safety & EMC
Safety Standards: Certified UL 60950-1; EN 60950-1
Withstand Voltage: I/P-O/P: 3KVAC (4242VDC), I/P-FG: 1.5KVAC (2121VDC), O/P-FG: 0.5KVAC (707VDC), 1min
Isolation Resistance: I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC
EMI Conduction & Radiation: Certified EN 55022; EN 61000-6-3
Harmonic Current: Certified EN 61000-3-2; EN 61000-3-3
EMS Immunity: Certified EN 61204-3; EN 55024; EN 61000-6-1, IEC 61000-4-2, 3, 4, 5, 6, 8, 11

Others
MTBF: 73.570K HRS Certified MIL-HDBK-217F
Cooling: Load and temperature control fan
Dimension (WxHxH): 127x63.5x280 mm / 5.000x2.500x11.024 inch
Packing: 3.2kg; 6pcs / 20.2kg / 1.86CUFT

Note
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. De-rating may apply in low input voltage. Please check the de-rating curve for more details.
5. In parallel connection, only one unit will operate if the total output load is less than 5% of the rated load condition.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
7. Conduct this test without enclosure.
Derating CurveUser-added image

 
Qty (ea.)/Carton6
Individual Box/Gift Box Size (mm)290*130*65
Individual Box/Gift Box ColorWhite
Master Carton Size (mm)TBD
Gross Weight (kg)20.2
Label Width (mm)110.0
Label Height (mm)30.0
Input Configuration
Description3 Positon Terminal BlockShanghai Elinker P/N: LG103-5.0
Approvals
LogoDescription
User-added imageAttention Mark / Refer to operating manual for operating and service instructions
User-added image  CE Certification
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
User-added image
Class I Earth Ground
User-added imageUL60950-1, cULus to UL 60950-1 E170507
User-added image
 
GOST-R mark for Russia(Document: http://www.globtek.com/html/iso_certificates/GT_GOST-R.pdf). 03/15/2015. Due to lack of demand, GlobTek will not be renewing it's GOST certification. Please contact your sales engineer for pricing on EAC.
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
User-added imageJAPAN TUV Rheinland-PSE GlobTek Inc to J60950-1(H26) , J55022(H22),J3000(H25).Please follow the procedure listed in the following link for proper import to Japan: http://en.globtek.com/importing-to-japan.php.
RoHS 2RoHS 2: Complies with EU 2011/65/EU and CHINA SJ/T 11363-2006 http://www.ce-mark.com/Rohs%20final.pdf
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products
SKUVolts OutCurrent Out (Amps)Connector
2521074831.25(1) Position Terminal Block

Request Info