GT-81085-15VV-x.x-W2 Wall Plug-in ICT/ITE Power Supply

GT-81085-15VV-x.x-W2
GT-81085-15VV-x.x-W2, ICT/ITE Power Supply, Wall Plug-in, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V ̴ , 50/60Hz, NEMA 1-15P, North America Blades, Class II 2 Conductors, Output Rating: 15 Watts, Power rating with convection cooling (W) , 5-24V in 0.1V increments, Approvals: RoHS; WEEE; China RoHS; Double Insulation; CB 60950; Level V; EC; cULus; IP41; LPS 60950; PSE; Designed to meet EN 60601-1; Level 3;GT-81085-15VV-x.x-W2, ICT/ITE Power Supply, Wall Plug-in, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V ̴ , 50/60Hz, NEMA 1-15P, North America Blades, Class II 2 Conductors, Output Rating: 15 Watts, Power rating with convection cooling (W) , 5-24V in 0.1V increments, Approvals: RoHS; WEEE; China RoHS; Double Insulation; CB 60950; Level V; EC; cULus; IP41; LPS 60950; PSE; Designed to meet EN 60601-1; Level 3;
Information
Model NumberGT-81085-15VV-x.x-W2
Agency Documentshttp://www.globtek.info/certs/GT-81085/
CE EC-Declaration for MedicalContact GlobTek for more information
CE EC-Declaration for Industrial/Commercial/ITEhttps://cs.globtek.info/ec_declaration?id=a0O30000007P7YyEAK
CE EC-Declaration for HouseholdContact GlobTek for more information
UKCA-Declaration for MedicalContact GlobTek for more information
UKCA-Declaration for Industrial/Commercial/ITEhttps://cs.globtek.info/ukca_declaration?id=a0O30000007P7YyEAK
UKCA-Declaration for HouseholdContact GlobTek for more information
Morocco SDoC Declarationhttps://cs.globtek.info/Morocco_SDoC_Declaration?id=a0O30000007P7YyEAK
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0O30000007P7YyEAK
Prop 65 Statementhttps://www.globtek.com/r2/PH7CNf
REACH Declarationhttps://www.globtek.com/r2/eM2co8
Conflict Minerals Declarationhttps://www.globtek.com/r2/vZY8R5
Model Parameters
TypeWall Plug-in
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor
CategoryICT/ITE Power Supply
Input Voltage Range (V)100-240V ̴ , 50/60Hz
Max Input Current (A)0.5A
Max Output Power Rating (W)15
Output Voltage Range (V)5-24
EfficiencyV
Ingress ProtectionIP41
Size (mm)69.0*28.8*45.0
EnclosureUser-added image
Rating Table
Model Number (Final ordering #/Part No to be defined)Voltage (V)Current (A)Power (W)RFQ
GT-81085-1307.5-2.5-W2*52.512.5
GT-81085-1307.5-1.5-W2*62.1612.96
GT-81085-1307.5-W2*7.51.7312.98
GT-81085-1513.5-4.5-W2*91.513.5
GT-81085-1513.5-1.5-W2*121.2515
GT-81085-1513.5-W2*13.51.114.85
GT-81085-1516.6-3.0-W2*13.61.114.96
GT-81085-1516.6-1.6-W2*15115
GT-81085-1516.6-W2*16.60.914.94
GT-81085-1524-6.0-W2*180.8314.94
GT-81085-1224-W2*240.512
* (Final ordering #/Part No to be defined)
Specifications
A) ELECTRICAL SPECIFICATIONS:
01.Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac
02. Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz
03. Output Regulation: +/- 5% measured at the output connector
04. Line Voltage Regulation: +/- 2% typical measured at full load
05. Output Ripple (Vp-p): +/-1% or 120 mV whichever is greater, measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with 10 uf electrolytic capacitor connected at the end of the output connector at nominal line
06. Turn-ON/OFF Overshoot: 5% maximum, 1 mS typical recovery time for 25% to 50% step load
07. Turn-ON Delay: 1 Sec, typical @ full load, nominal line
08. Hold-Up Time: 5 mS typical @ nominal input voltage and full load
09. Switching Frequency: 50 KHz typical

B) PROTECTION
01. Over-Voltage: Electronically Protected unit will auto recover upon removal of fault
02. Short Circuit: Electronically Protected unit will auto recover upon removal of fault
03. Input Protection: Input line fusing

C) SAFETY
01. Dielectric Withstand Voltage: 4242Vdc from primary to secondary
02. Touch Current: <0.25mA @ 240Vac input voltage

D) OTHER:
01. MTBF: 200,000 Hours @ 25°C ambient temperature
02. Operating Temperature: 0°C to 40°C ambient temperature
03. Humidity: 0% to 90% relative humidity
04. Storage Temperature: -10°C to 80°C
05. Cooling: Convection
06. Ingress Protection: IP41
07. ROHS 2: Complies with EU 2011/65/EU and China SJ/T 11363-2006

E) ENCLOSURE
01. Housing: High impact plastic, 94V0 polycarbonate, non-vented
02. Size: 69.0*28.8*45.0 +/-1.0 mm
03. Markings: Label and/or Pad Printed and/or Molded in the case
Derating Curvenull
Qty (ea.)/Carton120
Individual Box/Gift Box Size (mm)90*50*66
Individual Box/Gift Box ColorWhite
Master Carton Size (mm)470 x 320 x 300
Gross Weight (kg)15.6
Label Width (mm)33.8
Label Height (mm)16.3
Input Configuration
DescriptionNEMA 1-15P, North America Blades, Class II 2 ConductorsAll NEMA 1 devices are two-wire non-grounding devices (hot-neutral) rated for 125 V maximum. NEMA 1-15P plugs have two parallel flat blades, 0.25 inches (6.35 mm) wide, 0.06 inches (1.524 mm) thick, 0.625-0.718 inches (15.875–18.256 mm) long, and spaced 0.5 inches (12.7 mm) apart.
Output Configuration
Common output connector options:
Click to add to your request.
L Type (Coaxial 5.5x2.5mm plug)
C Type (Coaxial 5.5x2.1mm plug)
K Type (Coaxial 3.5x1.3mm plug)
LL Type (5.5x2.5mm Locking 760k type)
CL Type (5.5x2.1mm Locking S761k type)
Magnetic Connector
L Type (Coaxial 5.5x2.5mm plug)C Type (Coaxial 5.5x2.1mm plug)K Type (Coaxial 3.5x1.3mm plug)LL Type (5.5x2.5mm Locking 760k type)CL Type (5.5x2.1mm Locking S761k type)Magnetic Connector
YL3 Type (KPPX-3P)
YL4 Type (KPPX-4P)
EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)
MSB Type (Micro USB)
Custom design
YL3 Type (KPPX-3P)YL4 Type (KPPX-4P)EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)MSB Type (Micro USB)Inquire for custom design

Comprehensive list of GlobTek output cordset options

Contact GlobTek for your specific requirements or custom solutions.

Approvals

Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.

Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.

LogoDescription
User-added imageAttention Mark / Refer to operating manual for operating and service instructions
IP41Ingress Protection: ?IP41 to IEC60529:2001 Protection against granular foreign bodies - Protected against vertically falling drops of water
User-added imagenull
User-added imageJAPAN TUV Rheinland-PSE GlobTek Inc to J60950-1(H26) , J55022(H22),J3000(H25).Please follow the procedure listed in the following link for proper import to Japan: https://www.globtek.com/r2/Szj4Vb
No LogoEC-Conformity Declaration: http://www.globtek.com/html/iso_certificates/EC-DECLARATION.pdf, REACH 144 SVHC: http://www.globtek.com/html/iso_certificates/Reach144.pdf
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
No LogoDesigned to meet EN 60601-1:2006 + A11:2011 +A1:2013 3rd Edition
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://www.globtek.com/pdf/F-GT-DJD-8.4.1-006%20China%20RoHS%20Declaration%205-20-22.pdf
 User-added image

Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
LEVEL 3LEVEL 3
No Logo CB Certificate IEC 60950-1:2005 (2nd Edition), Am 1: 2009, CB report IEC 60950-1:2005 (2nd Edition), Am 1: 2009 and EN 60950-1:2006 + Am 1:2010 + Am 11:2009 + Am 12:2011
User-added image
UL60950-1, cULus to UL 60950-1, 2nd Edition, 2007-03-27 and CSA C22.2 No. 60950-1-07, 2nd Edition, 2007-03
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
LPSLimited Power Source 60950
Request Info