GT-41060-WWVV-X.X-FW Open Frame/Internal ICT/ITE Power Supply

GT-41060-WWVV-X.X-FW
GT-41060-WWVV-X.X-FW, ICT/ITE Power Supply,  60601-1-4th Ed. , Open Frame/Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, Molex 09-65-2038 3 Position Header Pin 1: Neutral, Pin 2: Removed, Pin 3: Line, Output Rating: 25 Watts, Power rating with convection cooling (W) , 3.0-30V in 0.1V increments, Approvals: Belarus (12V only); UKCA; RoHS; CE; Ukraine; cRUus  (up to 30V); China RoHS; Double Insulation; Level IV 1meter 115; NEMKO; VCCI; WEEE; FCC; LPS 60950; EAC; SIQ (up to 30V only);GT-41060-WWVV-X.X-FW, ICT/ITE Power Supply, 60601-1-4th Ed. , Open Frame/Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, Molex 09-65-2038 3 Position Header Pin 1: Neutral, Pin 2: Removed, Pin 3: Line, Output Rating: 25 Watts, Power rating with convection cooling (W) , 3.0-30V in 0.1V increments, Approvals: Belarus (12V only); UKCA; RoHS; CE; Ukraine; cRUus (up to 30V); China RoHS; Double Insulation; Level IV 1meter 115; NEMKO; VCCI; WEEE; FCC; LPS 60950; EAC; SIQ (up to 30V only);
Information
Model NumberGT-41060-WWVV-X.X-FW
Agency Documentshttp://www.globtek.info/certs/GT-41060/
CE EC-Declaration for Medicalhttps://cs.globtek.info/ec_declaration?id=a0O30000007P7ZJEA0
CE EC-Declaration for Industrial/Commercial/ITEhttps://cs.globtek.info/ec_declaration?id=a0O30000007P7ZJEA0
CE EC-Declaration for HouseholdContact GlobTek for more information
UKCA-Declaration for Medicalhttps://cs.globtek.info/ukca_declaration?id=a0O30000007P7ZJEA0
UKCA-Declaration for Industrial/Commercial/ITEhttps://cs.globtek.info/ukca_declaration?id=a0O30000007P7ZJEA0
UKCA-Declaration for HouseholdContact GlobTek for more information
Morocco SDoC Declarationhttps://cs.globtek.info/Morocco_SDoC_Declaration?id=a0O30000007P7ZJEA0
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0O30000007P7ZJEA0
Prop 65 Statementhttps://www.globtek.com/r2/PH7CNf
REACH Declarationhttps://www.globtek.com/r2/eM2co8
Conflict Minerals Declarationhttps://www.globtek.com/r2/vZY8R5
Model Parameters
TypeOpen Frame/Internal
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor
CategoryICT/ITE Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)0.6 A Max
Max Output Power Rating (W)25
Output Voltage Range (V)3.0-30
Efficiency
Ingress Protection
Size (mm)98*50*28
Enclosure
Enclosure size: 98*50*28 ± 0.5 mm

 User-added image
Input Connector: Molex 09-65-2038                                         Output Connector: Molex 22-27-2061
                                                                                                  or equivalent









 

 


                                  
 
Rating Table
Model Number (Final ordering #/Part No to be defined)Voltage (V)Current (A)Power (W)RFQ
GT-41060-1003-FW*32.67.8
GT-41060-1505-FW*5315
GT-41060-1706-FW*62.816.8
GT-41060-1809-FW*9218
GT-41060-2512-FW*122.0824.96
GT-41060-2515-FW*151.6624.9
GT-41060-2518-FW*181.3824.84
GT-41060-2520-FW*201.2525
GT-41060-2524-FW*241.0424.96
GT-41060-2530-FW*300.8324.9
GT-41060-2548-FW*480.5224.96
* (Final ordering #/Part No to be defined)
Specifications
NOTES:
1. Each output current may vary within it's designated range, as long as output power is not exceeded.
2. Single output may vary from 3VDC-30VDC in 0.1V increments.
3. Voltage differentiator X.X is optional, used only for specifying output voltage deviation from listed ratings.
Subtract X.X from rated voltage.

A) ELECTRICAL SPECIFICATIONS:
1. INPUT VOLTAGE: 100-240 VAC
2. INPUT CURRENT: < 0.6 A RMS MAX
3. INPUT FREQUENCY: 47 - 63 HZ
4. OUTPUT POWER: 25WATTS, MAXIMUM
5. OUTPUT RIPPLE VOLTAGE (PEAK TO PEAK): +/-1% OR 50 mV WHICHEVER IS GREATER AT NOMINAL
OUTPUT VOLTAGE.MEASURED AT 20 MHz BANDWIDTH WITH 0.1μf CERAMIC CAPACITOR IN PARALLEL WITH
10 μf ELECTROLYTIC CAPACITOR CONNECTED AT THE END OF THE OUTPUT CONNECTOR.
6. OUTPUT REGULATION: +/- 3 % OF NOMINAL OUTPUT VOLTAGE,
7. MEASURED AT O/P CONNECTOR AT NOMINAL LINE
8. LINE REGULATION: +/- 1 % MAX AT FULL LOAD
9. TURN ON/ TURN OFF OVERSHOOT: 5% MAX 500uS MAX RECOVERY TIME FOR 25% TO 50% STEP LOAD
10. TURN-ON DELAY: 3000 mSEC MAX AT FULL LOAD, 115 VAC
11. HOLD-UP TIME: 10 mSEC MIN AT NOMINAL INPUT AND FULL LOAD
12. INRUSH CURRENT: 30 A MAX AT COLD START 120 VAC, 60A MAX COLD START 230VAC
13. SWITCHING FREQUENCY: 66.5 KHz TYPICAL
14. OVER-VOLTAGE PROTECTION: PROTECTED, HICCUP WITH AUTO RECOVERY
15. OVER-LOAD: PROTECTED, HICCUP WITH AUTO RECOVERY
16. SHORT CIRCUIT: PROTECTED, HICCUP WITH AUTO RECOVERY
17. EFFICIENCY: 80% TYPICAL AT NOMINAL LINE
18. INDICATOR: BLUE LED FOR OUTPUT PRESENT
19. NO LOAD POWER CONSUMPTION: MEETS CEC/EISA LEVEL IV, 115 VAC

B) PROTECTION
1. OTHER PROTECTION: INPUT LINE AND NEUTRAL FUSING

C) SAFETY
1. DIELECTRIC WITHSTAND VOLTAGE: 4242 VDC PRIMARY-SECONDARY
2. LEAKAGE CURRENT: < 0.3 mA AT 240 VAC

D) OTHER:
1. MTBF: 200,000 HOURS AT 25°C AMBIENT TEMPERATURE
2. OPERATING TEMPERATURE: 0°C TO 40°C
3. STORAGE TEMPERATURE: -40°C TO 80°C
4. HUMIDITY: 0% TO 90% RELATIVE HUMIDITY
5. ROHS 2: COMPLIES WITH EU 2011/65/Eu AND CHINA SJ/T 11363-2006
Derating CurveUser-added image
Qty (ea.)/Carton100
Individual Box/Gift Box Size (mm)Egg Crate
Individual Box/Gift Box ColorNone
Master Carton Size (mm)469 x 395 x 250
Gross Weight (kg)15.6
Label Width (mm)18.0
Label Height (mm)15.0
Input Configuration
DescriptionMolex 09-65-2038 3 Position Header Pin 1: Neutral, Pin 2: Removed, Pin 3: LineDocument: http://www.molex.com/pdm_docs/sd/009652038_sd.pdf
Catalog Page: http://www.molex.com/molex/products/datasheet.jsp?part=active/0009652038_PCB_HEADERS.xml

User-added image
 

Mates With Part(s):

5195 SPOX™ Crimp Housing, 5239 KK® Crimp Housing
Optional Input Wiring Kits are available:

PN/Ordering No   Length  End A   End B
XHP410070M7MLX3(R)70JST XHP-4  Molex 09-93-0300
C810070M6MLX3(R)60IEC60320 C8  Molex 09-93-0300
C1410070M6MLX3(R)60IEC60320 C14  Molex 09-93-0300
Approvals

Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.

Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.

LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf

User-added image
 
Belarus certificate J\l By/I 12 03. 1 I . 020 05936 only for GTM41060-2512 and GT-41060-2512
User-added imagecRUus Registered E170507 CSA C22.2 No. 60950-1 2nd Ed. (up to 30V)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Nemko
NEMKO
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
LPSLimited Power Source 60950
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://www.globtek.com/pdf/F-GT-DJD-8.4.1-006%20China%20RoHS%20Declaration%205-20-22.pdf
User-added image  CE Mark: tested to comply with EN55022:2006/A1:2007 Class B, EN610003-2, EN610003-3 including EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6N EN61000-4-11; EMI: Complies with EN55011 CLASS B and FCC Part 15B - On label or Molded in case
UL FCC MarkFCC Mark
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
User-added imageUKCA Certification
 User-added image Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe) exception 5.1~6.9V require 1000 mm output cable
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added image  Certification # TC RU AR46.B.75423 Custom Union of Russia, Belarus and Kazakhstan
User-added imagenull
User-added image
 
IEC 60601-1:2005 (Third Edition) + CORR. 1:2006 + CORR. 2:2007 + A1:2012 (or IEC 60601-1: 2012 reprint) up to 30V only
Request Info