BL5000C21703S2PFS BL5000C21703S2PFS, , Battery Cylindrical Can, Battery Li-Ion, , Input Rating: , , Output Rating: Watts, Power rating with convection cooling (W) , V in 0.1V increments, Approvals: Information Guidelines and cautions, Safety Notes, and Safety Precautions published on GlobTek’s website Model Number BL5000C21703S2PFS Agency Documents http://www.globtek.info/certs/BL3500C1865001S1PCMK/ CE EC-Declaration for Medical Contact GlobTek for more information CE EC-Declaration for Industrial/Commercial/ITE Contact GlobTek for more information CE EC-Declaration for Household Contact GlobTek for more information UKCA-Declaration for Medical Contact GlobTek for more information UKCA-Declaration for Industrial/Commercial/ITE Contact GlobTek for more information UKCA-Declaration for Household Contact GlobTek for more information Morocco SDoC Declaration https://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0O3a00000OA4vtEAD RoHS/RoHS3 Declaration https://www.globtek.com/pdf/rohs_cert/a0O3a00000OA4vtEAD Prop 65 Statement https://en.globtek.com/prop-65-statement.pdf REACH Declaration https://www.globtek.com/pdf/iso_certificates/REACH.pdf Conflict Minerals Declaration https://www.globtek.com/pdf/conflict-minerals.pdf Model Parameters Type Battery Cylindrical Can Technology Battery Li-Ion Chemistry Li-Ion Cell Rated Capacity (mAh) 5000 Cell Nominal Voltage 3.6 Cell Geometry Cylindrical Cell Length 75 Cell Width 24 Cell Height 29 Cell Diameter Enclosure Rating Table Model Number (Final ordering #/Part No to be defined) Voltage (V) Current (A) Power (W) RFQ BL5000C21703S2PFS* RFQ
* (Final ordering #/Part No to be defined)
Specifications General Pack Specifications Description: Lithium-ion battery pack with SMBus-compatible battery management system (BMS) Includes Built-In Charger? No Includes Safety Protections? Yes Includes Fuel Gauge? Yes, via SMBus BMS Details: ICs: SH366006 + SH367202 PCB: 500-12011820(R) Cell configurations for which this electrical specification applies: 2s2p, 2s3p, 2s4p 3s2p, 3s3p, 3s4p 4s2p, 4s3p, 4s4p Definitions of nomenclature: The abbreviation (# 'p') is the "# of parallel strings" (i.e. the "Y" in XsYp) The abbreviation (# 's') is the "# of series cells in each string" (i.e. the "X" in XsYp)
Cell Specifications Cell P/N: LR2170SD Cell Designation/Marking: IEC61960, 2INR22/71 Nominal Cell Capacity: 5000mAh [Per cell manufacturer spec, 4.2V - 2.5V discharge, 0.2C, +25°C] Initial Internal Impedance per Cell: 30mΩ (max.) Cell Approvals: UL1642
Charge SpecificationsCompatible Charging Method: Constant current (CC) + constant-voltage (CV) SMBus Smart Charger Compatible (SBS)? Yes, pack suggests charging parameters based on measured pack temperature and SoC (SBS compatible chargers only) CC Current: 2p 3p 4p 0°C to +10°C 0.75A 1.125A 1.50A +10°C to +45C 2.00A 3.00A 4.00A
[Maximum recommend values & SMBus ChargingCurrent() defaults] CV Voltage: 4.125V • (# 's')> 2 s 3s 4s 8.250V 12.375V 16.500V
[Maximum recommended value & SMBus ChargingVoltage() default] Pre-Charge Current: When charging, if any cell's voltage is <2.70V, the charger should supply 0.075C [0.375A • (# 'p')] or less, until all cells are ≥2.70V [Maximum recommend values & SMBus ChargingCurrent() defaults] Charge-Termination Current: 0.05C [0.250A • (# 'p')]
Discharge Specifications Maximum Continuous Discharge Current: 8.0A Usable Discharge Capacity (typ.): 4500mAh • (# 'p') [4.125 - 2.8V discharge @ 0.2C] Cycle Life (typ.): 750 cycles [≥ 70% of 1st cycle capacity, [4.125 - 2.8V, 0.2C charge / 0.2C discharge, +25°C]
Environmental Ambient Temperature Range (in Charge): 0°C to +45°C Ambient Temperature Range (in Discharge): -20°C to +45°C Humidity: 0 - 85% RH Atmospheric Pressure: 86 - 106kPa Storage: Maintain SoC between 30 - 50% -20°C to +50°C 0 - 70% RH Suggested maintenance charge intervals: Every 3 months at -20°C to 25°C Every 1 month at -20°C to 50°C Handling: Please follow GlobTek, Inc. HANDLING AND SAFETY PRECAUTIONS FOR Li-Ion & Li-Polymer.
Recoverable Protection Parameters Over-Voltage in Charge: Trip: 4.225V ± 0.05V (any cell) Release: 4.025V ± 0.05V (any cell) Trip delay: 2s (typ.) Under-Voltage in Discharge: Trip: 2.80V ± 0.05V (any cell) Release: 3.10V ± 0.05V (any cell) Trip delay: 2s (typ.) Over-Current in Charge (typ.): Level Delay Trip threshold 2p 3p 4p 1 6s 2.67A 4.00A 5.32A 2 3s 3.50A 5.25A 7.00A
Over-Current in Pre-Charge (typ.) Trip delay: 2s Over-Current in Discharge (typ.): Level Delay Trip threshold 2p 3p 4p 1 6s 10.0A 10.0A 10.0A 2 3s 12.0A 12.0A 12.0A
Over-Temperature in Charge (typ.): Trip: 45°C Release: 40°C [Cell surface temperature] Under-Temperature in Charge (typ.): Trip: 0°C Release: 5°C [Cell surface temperature] Over-Temperature in Discharge (typ.): Trip: 60°C Release: 45°C [Cell surface temperature] Under-Temperature in Discharge (typ.): Trip: -20°C Release: -15°C [Cell surface temperature]
Non-Recoverable (Permanent Fail) Protection Parameters Method of deactivation: SCP (Electronically triggered fuse) Permanent Over-Voltage in Charge: Trip: 4.275V ± 0.05V (any cell) Trip delay: 5s (typ.) Permanent Over-Voltage in Charge (Standalone backup IC): Trip: 4.500V ± 0.05V (any cell) Trip delay: 6s (typ.) Permanent Under-Voltage in Discharge (typ.): Trip: 2.200 ± 0.05V (any cell) Trip delay: 5s Permanent Over-Current in Charge (typ.): Trip delay: 10s Permanent Over-Current in Discharge (typ.): Trip: 14.0A Trip delay: 5s Permanent Cell Over-Temperature (typ.): Trip: 65°C Trip delay: 10s [Cell surface temperature]
Approvals & Regulatory RoHS: Complies with 2011/65/EU + (EU)2015/863 and China SJ/T 11364-2014 CE: Complies with 2013/56/EU, including, but not limited to, EN61000-6-1:2007, EN61000-6-3:2007 Transportation: Approved to UN38.3 Safety: Designed to meet UL2054, IEC62133-2 (ed1.1)
Derating Curve Qty (ea.)/Carton Individual Box/Gift Box Size (mm) Individual Box/Gift Box Color White Master Carton Size (mm) TBD Gross Weight (kg) 90.0 Label Width (mm) Label Height (mm) Input Configuration Description Popular Products (Stock items) SKU Volts Out Current Out (Amps) Connector RFQ Sample Request 2763845 0.0 0.0 RFQ Sample Request
Guidelines and cautions, Safety Notes, and Safety Precautions published on GlobTek’s website http://en.globtek.com/safety-cautions.php
The purchaser of GlobTek battery pack products (Customer) agrees that they are a "Sophisticated user" who understands battery technology and that it is their sole responsibility to determine suitability of the product described for their application and to take precautions for protection against any hazards attendant to the handling and use of the product. GlobTek products are only designed for professional use and integration by companies into their products and may not be used by consumers directly. GlobTek provides batteries and battery packs as a component of an end system.
The acceptance of GlobTek specifications, the information on this page and use of the product(s) described in this or other GlobTek documents indicate that the product was qualified for use (tested and/or sample waiver signed), and the acceptance and binding of the customer to GlobTek terms and conditions, which supersede all other agreements, terms and conditions http://en.globtek.com/terms-and-conditions/
Lithium Ion batteries are inherently dangerous. Continuous usage or charging without allowing the battery to discharge is a hazard.
FIRE HAZARD: This like all Li-Ion battery packs must be regularly discharged and charged. it is not recommended to be kept on permanent fullcharge and in a full state of charge.