90 W, DoE Level VI & CoC Tier 2 Efficiency, Two Prong (C8) Inlet, Desktop Adapter, Ac-Dc Power Supply

GTM96900P90VV.V-T2
The 90W Desktop Power Supply family also serves as an LED Driver which meets 61000-3-2 Class C Harmonics and has IEC61347, LPS, and UL1310 (Class 2 Transformer) certification, Class II. The 90W Desktop Power Supply family also serves as an LED Driver which meets 61000-3-2 Class C Harmonics and has IEC61347, LPS, and UL1310 (Class 2 Transformer) certification, Class II.The 90W Desktop Power Supply family also serves as an LED Driver which meets 61000-3-2 Class C Harmonics and has IEC61347, LPS, and UL1310 (Class 2 Transformer) certification, Class II. The 90W Desktop Power Supply family also serves as an LED Driver which meets 61000-3-2 Class C Harmonics and has IEC61347, LPS, and UL1310 (Class 2 Transformer) certification, Class II.
Information
Model NumberGTM96900P90VV.V-T2
Agency Documentshttp://www.globtek.info/certs/GTM96900P90VV.V/
CE EC-Declaration for Medicalhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000MigSZEAZ
CE EC-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000MigSZEAZ
CE EC-Declaration for Householdhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000MigSZEAZ
UKCA-Declaration for Medicalhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000MigSZEAZ
UKCA-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000MigSZEAZ
UKCA-Declaration for Householdhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000MigSZEAZ
Morocco SDoC Declarationhttps://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0Oa000000MigSZEAZ
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0Oa000000MigSZEAZ
Prop 65 Statementhttps://en.globtek.com/prop-65-statement.pdf
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeDesktop/External
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor
CategoryICT / ITE / Medical Power Supply/Class 2/Household Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)1.5A
Max Output Power Rating (W)90
Output Voltage Range (V)12-54
EfficiencyUSA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782
Ingress ProtectionIP41
Size (mm)149.38 x 62.6 x 33.5 +/-1.0
EnclosureUser-added image
Alternative housing with input cord clamp to prevent accidental removal of the power cord. Product PN# ends with suffix "CL"
User-added image
3D File Downloadhttps://www.globtek.com/dl/GTM96900-GTM961200-T2.igs
Rating Table
Preferred ratings shown below.
Custom output voltages available in 0.1V increment from the minimum voltage listed to the maximum voltage listed; contact sales.
Model Number (Final ordering #/Part No to be defined)Voltage (V)Current (A)Power (W)LPSRFQ
GTM96900P9012.5-T2*12.57.290
GTM96900P9012.8-T2*12.8789.6
GTM96900P8512-T2*127.185.2N
GTM96900P9013-T2*136.9289.96
GTM96900P9014-T2*146.42889.99
GTM96900P9017-T2*175.29490
GTM96900P9025-T2*253.690
GTM96900P9026-T2*263.46189.99
GTM96900P9027-T2*273.33389.99
GTM96900P9028-T2*283.21489.99
GTM96900P9029-T2*293.10389.99
GTM96900P9031-T2*312.90389.99
GTM96900P9032-T2*322.81289.98
GTM96900P9033-T2*332.72789.99
GTM96900P9034-T2*342.64790
GTM96900P9036-T2*362.590N
GTM96900P9037-T2*372.43289.98
GTM96900P9038-T2*382.36889.98
GTM96900P9039-T2*392.30789.97
GTM96900P9040-T2*402.2590
GTM96900P9041-T2*412.19590
GTM96900P9042-T2*422.14289.96
GTM96900P9045-T2*45290
GTM96900P9043-T2*432.09390
GTM96900P9044-T2*442.04589.98
GTM96900P9046-T2*461.95689.98
GTM96900P9049-T2*491.83689.96
GTM96900P9050-T2*501.890
GTM96900P9051-T2*511.76489.96
GTM96900P9052-T2*521.7389.96
GTM96900P9053-T2*531.69889.99
GTM96900P4524-T2*241.87545
GTM96900P4536-T2*361.2545Y
GTM96900P8512-T2Z*127.185.2Y
GTM96900P9015-T2Z*15690Y
GTM96900P9019-T2Z*194.7389.87Y
GTM96900P9024-T2Z*243.7590Y
GTM96900P9030-T2Z*30390Y
GTM96900P9036-T2Z*362.590Y
GTM96900P9048-T2Z*481.87590Y
GTM96900P9054-T2Z*541.6689.64Y
GTM96900P5436-T2*361.554Y
GTM96900P6536-T2*361.80665.02Y
GTM96900P5136-T2*361.41650.98N
GTM96900P5124-T2*242.12551N
GTM96900P5036-T2*361.3849.68N
GTM96900P9013.5-T2*13.56.689.1
GTM96900P9022-T2Z*22.04.0989.98Y
GTM96900P4512-T2*123.7545
GTM96900P9030-T2*30390N
GTM96900P9029.4-T2*29.43.06189.99
GTM96900P9012-T2*127.590
GTM96900P9016-T2*165.62590
GTM96900P9024-T2*243.7590N
GTM96900P9035-T2*352.5789.95
GTM96900P9048-T2*481.87590N
GTM96900P9054-T2*541.6689.64N
GTM96900P9015-T2*15690N
GTM96900P9018-T2*18590
GTM96900P9019-T2*194.7389.87N
GTM96900P90VV.V-T2-XXXXCUSTOMCUSTOMCUSTOMCUSTOM
* (Final ordering #/Part No to be defined)
Specifications

Input

Input Voltage:Specified: 90-264VAC, Nameplate: 100-240VAC
     100% rated load current for 90-264VAC
       90% rated load current for 85-264VAC
     100% rated load current for 90-370VDC
Input Frequency:Specified: 47-63Hz, Nameplate: 50-60Hz
Power Factor:0.90 min. @ 230VAC, 0.97 min. @ 115VAC
No Load Input Power:< 150mW @ 115/230VAC
Inrush Current:< 65A @ 115VAC, < 130A @ 230VAC (cold start)
Efficiency:DoE Level VI and EU CoC Tier 2 compliant

Output

Turn-on Delay:1 second typ.
Output Regulation:± 4% (measured at output connector)
Line Regulation:± 0.5% typ. (measured at output connector, full load)
Ripple:1% or 200mV, whichever is greater (using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW, at output connector)
Startup Overshoot:5% max.
Transient Response:5% max. deviation, 1ms typ. recovery time (with 25% to 50% load step)
Hold-up Time:20ms min.
Power Indicator:Green LED
Switching Frequency:Variable, 25KHz - 125KHz, depending on load
Output Type:Z-suffix only: IEC62368-1 Limited Power Source (LPS), 8A and 100W max.

Protections

Input Protection:300VAC MOV transient suppressor, input line fusing
Over-Current Protection (Non-LPS Version):110 - 160% of rated output current, auto-restart
Over-Current Protection:
(LPS "Z" Version)
Overload limited to less than 8A and less than 100W, auto-restart
Short-Circuit Protection:Auto-restart
Over-Voltage Protection:110 - 135% (60V max for models rated 45 - 54V), full load condition, latched off, cycle AC to reset
Over-Temperature ProtectionOn-chip temperature sensor (integrated in primary-side switching controller), shut down at Tj = ~150°C, restart at Tj = ~140°C

Environmental

MTBF:1,500,000 hours @ 25°C ambient, full load (Telcordia SR-332, Issue 3)
Operating Temperature:-10°C to 40°C (full load)
Storage Temperature:-30°C to 80°C
Humidity:0% to 95% relative humidity, non-condensing
Altitude:5000m
Cooling:Convection
RoHS:Complies with EU 2011/65/EU and China SJ/T 11363-2006
Note 1:Regarding operating temperature
a. See below de-rating table for output power capability at alternate temperature
b. Extended low-end temperature range available as a custom option

Safety

Dielectric Withstand Voltage:4000VAC or 5656VDC from input to output
3000VAC or 4242VDC from input to earth (Class I models only)
Touch Current:Class I: 20µA max.
Class II: 70µA max.
Earth Leakage CurrentClass I: 300µA max.
Class II: N/A
Means of Protection:2 x MOPP
Output Isolation Options:Class I: C6 or C14 inlet (output negative tied to Earth contact)
Class II: C8 or C18 inlet
Class II FE: C6 or C14 inlet (output isolated from Earth contact)
Review isolation options by reading our white paper PSU Isolation and Identity.
Primary-to-Secondary Bridging Capacitors:Two IEC60384-14 Class Y1 capacitors
Earth Continuity Test:< 0.1Ω between earth pin (on AC inlet) and PCB termination point (Class I models only)
Compliant Standards:See listing at end of this datasheet for specific standards

EMC

Applicable Standards:Medical: EN60601-1-2, 4th edition
Emissions: EN55032, EN61000-6-3, EN61000-6-4, CISPR11, CISPR22
Immunity: EN55024, EN61000-6-1, EN61000-6-2
Conducted Emissions:Class B, FCC Part 15, Class B (with resistive load)
Radiated Emissions:Class B, FCC Part 15, Class B (with resistive load)
Harmonic Current Voltage Distortion:EN61000-3-2, Class A
Voltage Fluctuations/Flicker:EN61000-3-3
Electrostatic Discharge (ESD) Immunity:EN61000-4-2, 10KV contact discharge, 18KV air discharge
Radiated RF Immunity:EN61000-4-3, 10V/m 80-1000MHz,  3V/m 1-2.7GHz, 80% 1KHz AM
EFT/Burst Immunity:EN61000-4-4, 4KV/100kHz.
Line Surge Immunity:EN61000-4-5, 2KV differential, 4KV common-mode
Conducted RF Immunity:EN61000-4-6, 3VRMS, 80% 1KHz AM
Power Frequency Magnetic Field Immunity:EN61000-4-8, 3A/m
Voltage Dip Immunity:EN61000-4-11

Enclosure

Housing:High impact plastic, 94V0 polycarbonate, non-vented
Size:149.4 * 62.6 * 33.5mm, ± 1.0mm
AC Input Mechanical Options:C6, C8, C14, or C18 IEC inlet
Markings:Label and/or pad printed and/or laser-etched into case

Special Options

  1. IEC62368-1 Limited Power Source (LPS) version (add Z suffix)
  2. Reduced leakage current to meet IEC60601-1 Type-CF limits
  3. Improved EN61000-4-5 line surge immunity (3KV differential, 5KV common-mode)
  4. Reduced harmonic current levels for LED lighting (EN61000-3-2 Class C), available in three load ranges: 27-45W, 40-60W, and 60-90W
  5. Ruggedized construction with improved shock and vibration resistance
  6. Compliance to IPC-600, IPC-610, IPC-6012 Class 2 or 3
  7. Short term output surge capability for motors or other high peak current loads (non-LPS version only)
  8. Custom cordsets, special cordage and connector types
  9. Custom housing markings
  10. Custom housing/cordage colors
  11. Tightened output voltage tolerance
  12. Reduced output ripple level
  13. Reduced output power rating
  14. Low temperature option, down to -40°C
  15. Epoxy potted version "P2" or "P3" suffix, with flying wires or custom cables
  16.  "Back EMF" upgrade, for motor loads and other high inductance applications with reverse energy flow requirements
  17. Improved ingress protection (IP) rating

Output Connectors

 

 

Derating CurveUser-added image
Qty (ea.)/Carton20
Individual Box/Gift Box Size (mm)Egg Crate
Individual Box/Gift Box Color
Master Carton Size (mm)427 x 405 x 158
Gross Weight (kg)15.6
Label Width (mm)50.0
Label Height (mm)110.0
Input Configuration
DescriptionIEC 60320/C8 AC Inlet connector, Class II, Non-Earth Ground (aka "Figure-8")
User-added image
Mates with IEC 60320/C7 Plug

Below are standard cordsets which are "not included" (unless stated above); these may be purchased separately or packaged with the power supply. Please contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material.

Standard International IEC 320/C7 Cordsets 
Part NumberTypeStandardConnectorLength (mm)Length (feet)
2094112M703(R)Argentina (Type I)IRAM 2063IEC 320/C720007
5014112M703A(R)Australian (Type I)AS 3112IEC 320/C720007
207B4111M8703(R)Brazil (Type N)NBR14136IEC 320/C718006
4533501M8703(R)China (Type A)GB 2099.1IEC 320/C718306
2074112M703A(R)European (Type C)CEE 7/16IEC 320/C720007
2074112M703AEUSA(R)European/South Africa Combo(Type C)CEE 7/16IEC 320/C720007
2084111M8703B(R)India (Type D)IS 1293IEC 320/C718006
451J3401M8703(R)Japan (Type A)JIS 8303IEC 320/C718306
2044112M703A(R)Korea (Type C)KS C8305IEC 320/C720007
4511116F703A(R)North America (Type A)NEMA 1-15PIEC 320/C718306
2084111M8703(R)South Africa (Type M)BS 546IEC320/C718306
4033401M8703A(R)Taiwan (Type A)CNS690IEC 320/C718306
6104112M703A(R)UK, Hong Kong, Singapore, Gulf States (Type G)BS1363IEC 320/C720007
451G1116F703A(R)Gulf States (Kuwait, Bahrain, Oman, Qatar, Saudi Arabia, Yemen and the United Arab Emirates (UAE)(Type A)Nema 1-15PIEC320/C718306
6303742M5703(R)Thailand (Type C)TIS 166-2549IEC320/C725008
Output Configuration
Common output connector options:
Click to add to your request.
L Type (Coaxial 5.5x2.5mm plug)
C Type (Coaxial 5.5x2.1mm plug)
K Type (Coaxial 3.5x1.3mm plug)
LL Type (5.5x2.5mm Locking 760k type)
CL Type (5.5x2.1mm Locking S761k type)
Magnetic Connector
L Type (Coaxial 5.5x2.5mm plug)C Type (Coaxial 5.5x2.1mm plug)K Type (Coaxial 3.5x1.3mm plug)LL Type (5.5x2.5mm Locking 760k type)CL Type (5.5x2.1mm Locking S761k type)Magnetic Connector
YL3 Type (KPPX-3P)
YL4 Type (KPPX-4P)
EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)
MSB Type (Micro USB)
Custom design
YL3 Type (KPPX-3P)YL4 Type (KPPX-4P)EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)MSB Type (Micro USB)Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals

Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.

Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.

LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
CAN ICES-3(B)/NMB-3(B)
Compliance of this PSU with Industry Canada, Class B demonstrated with a standard output load. The ICES law stipulates that system-level testing is required to demonstrate compliance with the ICES-3 emission limits with the actual system load.
Conforms to AAMI STD.ES60601-1,IEC 60601-1-11
Certified to CAN/CSA STD.C22.2 NO.60601-1
Conforms to AAMI STD.ES60601-1,IEC 60601-1-11 Certified to CAN/CSA STD.C22.2 NO.60601-1
Conforms to UL STD. 1310
Certified to CSA STD. C22.2 NO.223
Conforms to UL STD. 1310 Certified to CSA STD. C22.2 NO.223
Conforms to UL STD. 60950-1 
Certified to CSA STD C22.2 NO.60950-1
Conforms to UL STD. 60950-1 Certified to CSA STD C22.2 NO.60950-1

No Logo Applicable

CB for IEC61347-1:2015 + A1:2017 IEC61347-2-13:2014, A1:2016
User-added imageRCM certificate GMA-514113-EA; Australia and New Zealand Regulatory Compliance, Mark (http://rcm.standards.org.au/rcmfaq/rcmfaq.htm)
LPSLimited Power Source if Z suffix on model number
User-added imageCCC Altitude up to 5000 m GB17625.1-2012, GB4943.1-2011, GB/T9254-2008
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added image  Declaration ДС № ЕАЭС N RU Д-US.КА01.В.10453_19 Custom Union of Russia, Belarus and Kazakhstan http://www.globtek.com/redirect/?loc=gost-certificate-eac-declaration
User-added image
 
S-Mark Certificate EN 62368-1:2014 + A11 (http://www.intertek.com/marks/s/)
User-added image
PRECAUCION: PARA USO EN EQUIPOS ELECTRONICOS SOLAMENTE
 
IRAM certificateDC-E-G71-005.1 to IEC 62368-1:2014


 
ETL (Brazil) to IEC 62368-1;2014 DOC cert
User-added image
 
UKCA Certification
User-added imageUL1310 Warning Label Up To 36 Volts with plugs
Conforms to UL STD. 62368-1
Certified to CSA STD C22.2 NO.62368-1
Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1
User-added imageAudio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [UL 62368-1:2014 Ed.2] Audio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [CSA C22.2#62368-1:2014 Ed.2]
LPSLimited Power Source if Z suffix on model number 62368
User-added image
 
Morocco SDoC declaration http://www.globtek.info/certs/Morocco%20SDoC%20Declaration/
 No LogoSOUTH AFRICAN EMI/EMC SABS
User-added imageBook 60335 up to 36 Volts
User-added image
 
S-Mark Certificate EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011+A2:2013 (http://www.intertek.com/marks/s/)

No Logo Applicable

CB for IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013
User-added imageInformation Technology Equipment Safety Part 1: General Requirements >Valid without technical revision: 01Jan2022< [UL 60950-1:2007 Ed.2 +R:14Oct2014]
User-added image
Class 2 Power Unit
Class 2 Power Units [UL 1310:2011 Ed.6 +R:12Dec2014] up to 5A Power Supplies With Extra-Low Voltage Class 2 Outputs [CSA C22.2 No.223:2015 Ed.3]

No Logo Applicable

CB for IEC 60335-1:2010 (Fifth Edition) incl. Corr. 1:2010 and Corr. 2:2011 + A1:2013

No Logo Applicable

CB for IEC 62368-1:2014 (Second Edition)
User-added imageMedical Electrical Equipment - Part 1: General Requirements For Basic Safety And Essential Performance (R2012) [AAMI ES60601-1:2005 +C1;A2] [CSA C22.2#60601-1:2014 Ed.3] [AAMI HA60601-1-11:2015 Ed.2]

No Logo Applicable

CB for IEC 60601-1:2006/A1:2013+A12:2014 IEC 60601-1-11:2015
User-added image
 
S-Mark Certificate EN 60601-1:2006 + A1:2013 + A12:2014 EN 60601-1-11:2015 (http://www.intertek.com/marks/s/)
User-added image  Test standard: EN 55032: 2012+AC: 2013 EN 61000-3-2:2014 EN 61000-3-3:2013 EN 55024:2010 EN 60601-1-2:2015
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
User-added image
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
IP41Ingress Protection: ?IP41 to IEC60529:2001 Protection against granular foreign bodies - Protected against vertically falling drops of water
 User-added image
 
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
Patent pendingPatent pending
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[15V or less]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50313287, to J60950-1(H26) , J55022(H22),J3000(H25)[DC15?30V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50313287, to J60950-1(H26) , J55022(H22),J3000(H25)[DC30?60V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample Request
67893312.07.5
76765633.02.72
TR9KX166T00-IM(R6B)54.01.66
76765524.03.75
61384836.01.38
63603836.02.5
70170136.01.41
61013024.02.125
60168636.02.5
59773136.02.5
70148124.01.875
61744736.01.8
TR9KE7080LCPCR6BLPS12.07.08
TR9KX1875T00-IM(R6B)48.01.875
54123330.03.0
TR9KG6000LCP-IM(R6B)15.06.0
53762224.01.87
52276424.03.75
55652112.07.5
TR9KG6000T00-IM(R6B)15.06.0
61013636.01.5
39753754.01.66
TR9KE7500CCP-IM(R6B)12.07.5
TR9KZ4737T00-IM(R6B)19.04.73
TR9KH5000T00-IM(R6B)18.05.0
TR9KI3750CCP-IM(R6B)24.03.75
35882430.03.0
TR9KI3750T00-IM(R6B)24.03.75
TR9KI3750LCPCIM(R6B)24.03.75
TR9KE7500LCP-IM(R6B)12.07.5
35881712.07.5
239845412.03.75
227652830.03.0
206936124.03.75
199371024.03.75
216723224.03.75
170972724.03.75
160272624.03.75
157027624.03.75
134136542.02.14
132434448.01.875
169092724.03.75
57249112.07.08
22117924.03.75
262677712.05.0
184581819.04.73
159194324.03.75
159111324.03.75
122082624.03.8
240783224.03.75
239185724.03.75
238421112.07.08
233197212.07.5
212796615.06.0
212753515.06.0
40999624.03.8
478935
506119
53895636.01.3
60511624.01.7
61570936.01.3
67682712.07.5
55641312.07.1
287390
What is a IEC 60601-1-11 home healthcare power supply?

The FDA defines a home use medical device as “a device intended for users in a non-clinical or transitory environment, which is managed partly or wholly by the user, requires adequate labeling for the user, and may require training for the user by a healthcare professional in order to be used safely and effectively. This includes permanently and temporarily implanted devices and any type of equipment that a person may use to recover and rehabilitate.” 

IEC 60601-1-11 is the current version of collateral standard IEC 60601-1 that applies to the basic safety and essential performance of medical electrical equipment used in home settings. Effective June 30, 2013 in the European Union and December 31, 2013 in the U.S., the new standard differs from the previous edition(s) in several key ways. It now requires a ‘Class II’ electrical categorization of medical equipment, an elevated ingress protection (IP), and systems for home use and expands the definition of the ‘home environment’ to include European nursing homes. 


a IEC 60601-1-11 home healthcare power supply is an AC to DC converter which complies with the standards specified in IEC 60601-1-11. aside from the basic requirements for medical power supplies such as elevated dielectric with stand voltage and low leakage current home health care power packs also require to be Class II and a minimum ingress protection level of IP21. IEC 60601-1-11 is also listed inside of the product CB, UL, and other regulatory reports.


How do I know if I need an IEC 60601-1-11 home healthcare power supply adapter?

The final use application and where that device would be used would dictate if it's necessary to comply with IEC 60601-1-11 . 

Are there any restrictions as to the type of power supply that could qualify as IEC 60601-1-11 ?

Most types of GlobTek medical power supplies and AC to dc adapters qualify as IEC 60601-1-11. GlobTek offers both external desktop or wall plug-in power supplies that meet the standard. The main constraints for the AC to DC adapters to meet IEC 60601-1-11 are that they are class II and have an elevated ingress protection level.  What is an IEC 60601-1 medical grade rated power supply AC adapter?

An IEC 60601-1-2 medical grade rated power supply AC adapter converts input line voltage from the wall to a lower voltage, typically DC, which is used to operate and end use piece of medical equipment. IEC 60601-1-2 medical grade power supply AC adapters are typically housed in a plastic enclosure and are available with both 2 and 3 prong input options. power supplies are also available as open frame for use inside of medical equipment. These AC to DC converters are designed in accordance with international medical standards and provide for compliance with certain aspects of them which differs from generic information and communication technology equipment power supplies.

Why is my medical grade IEC 60601-1 power supply certified to IEC 60601-1 3rd Edition while the latest standard is IEC 60601-1 4th Edition?
IEC 60601-1 has different sections in specifications for safety and EMI/EMC. The latest revision of the safety portion of  IEC 60601-1 is 3rd Edition while for EMI/EMC the latest revision is 60601-1-2, 4th Ed. 

What is the effective date of 60601-1-2, 4th Ed?
60601-1-2, 4th Ed. was effective on December 31, 2018.

What's the difference between an IEC 60950-1 and IEC 60601-1 medical grade rated power supply?

IEC 60950-1 and IEC 60601-1-2 power supplies are both AC to DC converters and may be either internal or external but are designed to different specifications to match the end system specifications. While the basic performance behaviors are similar such as input and output voltages and mechanical configurations, there are many differences as well. Some of the key differences are that medical IEC 60601 medical grade AC to DC adapters are able to withstand a higher dielectric withstand voltage and must have lower leakage current.  There are many other differences and also considerations to consider depending on the end use application.  

What MOOP and MOPP?
Medical devices must incorporate one or more Means of Protection (MOPs) to isolate patients and operators from the risks of electrocution. A Means of Protection (MOPs)  can be safety insulation, a protective earth, a defined creepage distance, or an air gap or other protective impedance. These can be used in various combinations. IEC 60601-1 3rd edition differentiates between the risk to patients and the risk to operators. A MOP can therefore be classified as Means of Patient Protection (MOPP) or a Means of Operator Protection (MOOP). The main difference between one MOOP and one MOPP is primarily one of permissible creepage distance. Both requirements are satisfied using Basic insulation. To achieve 2 x MOPP qualification the isolation test is particularly demanding at 4000 Vac and the creepage distance of 8mm is twice that required for one MOPP. 

What is a BF and CF rated an IEC 60601-1-2 medical grade rated power supply AC adapter and what is the difference?

Medical grade power supplies and AC to DC adapters are categorized into one of three applied parts types: body type (B), body floating type (BF), and cardiac floating type (CF). These applied parts require specific attributes such as isolation voltage, creepage and leakage current. Floating refers to an ungrounded power supply, Class II, that is not referenced to another output and is fully isolated. Type B refers to devices that operate within the patient's vicinity, as described in IEC 60601-1 as six feet around a patient's chair or bed and do not touch the patient electronically and are grounded. These devices include operating room lighting, hospital carts and beds, automated dispensers of medication and supplies, and diagnostic equipment like x-ray machines. Type BF devices deliver electrical energy signals to or from the patient such as electrosurgical devices, endoscopes, and electrical vital sign monitors like thermometers. Type CF devices are similar to BF, except they supply power to devices connected to the heart, such as a defibrillator, external pacemaker or intracardiac ECG electrodes and Type CF requires a higher degree of protection against electrical shock than BF types.  
 

Is level VI efficiency required for power over Ethernet?

According to the department of energy of the United States,  An EPS may be considered a Class A EPS if it connects to the end-use application using any type of electrical connection, cable, cord, or other wiring, including both removable and hard-wired connections. An Ethernet cable would meet these criteria, so an EPS that connects to the end-use product via an Ethernet cable would still be considered a Class A EPS and would be subject to the applicable energy conservation standards if it meets the other  five criteria of a Class A EPS. In general all power over ethernet power supply adapters meet all criteria and are required to be level VI efficiency.

What is a IEC 62368-1:2018 power supply?

IEC 62368-1:2018 is applicable to the safety of electrical and electronic equipment within the field of audio, video, information and communication technology, and business and office machines with a rated voltage not exceeding 600 V. This is a product safety standard that classifies energy sources, prescribes safeguards against those energy sources, and provides guidance on the application of, and requirements for, those safeguards. The prescribed safeguards are intended to reduce the likelihood of pain, injury and, in the case of fire, property damage. An IEC 62368-1 rated AC to DC converter or power supply is a power supply that has been tested to and certified to comply with the said standard.

Did IEC 62368-1 power supplies replace IEC60950-1 power supplies?

On December 20, 2020 the safety standards that historically have applied to information technology equipment and audio video equipment, IEC 60065 and IEC 60950-1,transition to IEC 62368-1. In North America ETL and UL 60950-1 certifications will continue to stay valid and may continue to be used until further notice. 

What is the difference between an IEC 62368-1 and a IEC 60950-1 power supply?

While the structure and contents of the standards are very different in general most products that previously complied with IEC 60950-1 comply with the latest standard IEC 62368-1 with little or no modification.

Will my IEC60950-1 power supply remain available?

GlobTek will continue to manufacture and supply IEC 60950-1 power supplies indefinitely until further notice.

What is Level VI Efficiency?

The numerals I to VI are an International Efficiency Marking Protocol which allows manufacturers to designate the efficiency performance of a product. This performance is based on the measurement of the operating energy efficiency and no-load power consumption of external power supplies or AC DC adapters tested at different load levels. The no-load power consumption refers to the amount of power that an external power supply draws even when the application is turned off or disconnected.

Is Level VI Efficiency required?

Level VI efficiency is mandated in certain countries and regions for certain products or certain applications.

What is the Eco-design Directive 2009/125/EC?

The Eco-design directive put into law in Europe the latest requirements for energy efficiency and conservation for AC DC adapters and external power supplies.

What is IEC 60335-1?

The International Standard 60335-1 covers the safety of electrical appliances for household and similar purposes with rated voltage not more than 250 V for single-phase appliances and 480 V for other appliances.

Why is an IEC 60335-1 rated power supply or AC adapter necessary?

Applications used in the household environment are mandated to use and IEC 60335-1 certified power supply or AC to DC converter. These unique power supplies provide for specific compliance necessary for household use appliances.

What is the The Unique Device Identification (UDI) for my GlobTek medical grade power supply?

The Unique Device Identification (UDI) as required by the Food and Drug Administration Amendments Act of 2007 and EU Medical Device Regulation (MDR) is required for registered medical devices. While GlobTek medical grade power supplies carry full medical certifications they're actually not considered medical devices themselves but a component of such. And therefore do not have registration with the Food and Drug Administration Amendments Act of 2007 and EU Medical Device Regulation (MDR) and therefore so not carry a The Unique Device Identification (UDI).

What is an LPS (Limited power source)?

A Limited Power Source (LPS) as defined in IEC 62368-1 and IEC 60950, is a secondary circuit with an open circuit output voltage, UOC, not exceeding the SELV circuit limits of 42.4 VPEAK or 60 VDC. The maximum apparent power, S, available on the output under any load condition, and the maximum fault current, ISC, available on the output under any load condition, (including a short-circuit), are limited to magnitudes not likely to cause ignition under fault condition in components mounted on, or circuits constructed from, suitably rated materials.

Why is a LPS (limited power source) necessary?

Providing LPS (limited power source) limitations to part or all of the circuits in a product design gives the mechanical design more flexibility in polymeric material choices and openings in the enclosure, as a fire enclosure need not be provided for LPS-powered circuits.

Can a Class 2 power unit or UL1310 power supply be replaced by an LPS (limited power source)?

Many and product standards will stipulate the use of either an LPS rated 62368-1 power supply or AC to DC converter or a Class 2 power unit certified to UL 1310. If the end product standard allows for the substitution of a class 2 power unit with an LPS rated supply one may be used.

What is the difference between a Class 2 power unit certified to UL 1310 and a LPS (limited power source)?
UL1310 is a product safety standards which aims to keep humans safe by lowering the possibility of a hazardous situation. UL1310 requires that all AC/DC power supplies and AC/DC adapters carrying UL1310 certification have limited output power capability. The limits are defined in Section 28 of the standard. UL 1310 AC adapters and power supplies are also known as Class 2 Transformers. IEC62368-1 gives the name “Limited Power Source” (LPS) to a class of AC to DC and DC to DC power supplies which meet a set of criteria defined in Annex Q of the standard. It is important to note that a power supply certified to IEC62368-1 does not imply that it also LPS compliant; LPS compliance is optional. The two essentially require the same technical requirements but differ in marking requirements on the nameplate.

How Does an AC-DC Wall Adapter Work?

The AC to DC adapter or external power supply consists of a power supply which is enclosed in a housing similar to an AC plug, hence the term plug type, wall plug in, plug-in or plugtop power adapter. The power supply is plugged into the mains socket and the AC Voltage is then converted by the AC to DC adapter power supply into a DC voltage that is fed into the appliance via the output cable connection.

Request Info
Call
Email
💬
Text
💁
Chat
?
Request a Quote
Can we help you?
Can we help you?