90 W, DoE Level VI & CoC Tier 2 Efficiency, Three Prong (C14) Inlet, Desktop Adapter, Ac-Dc Power Supply

GTM96900P90VV.V-T3 Image
Model Image 90 W, DoE Level VI & CoC Tier 2 Efficiency, Three Prong (C14) Inlet, Desktop Adapter, Ac-Dc Power Supply
Information
Model NumberGTM96900P90VV.V-T3
Description90 W, DoE Level VI & CoC Tier 2 Efficiency, Three Prong (C14) Inlet, Desktop Adapter, Ac-Dc Power Supply
Agency Documentshttp://www.globtek.info/certs/GTM96900P90VV.V/
CE EC-Declaration for Medicalhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000MjSZHEA3
CE EC-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000MjSZHEA3
CE EC-Declaration for HouseholdContact GlobTek for more information
UKCA-Declaration for Medicalhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000MjSZHEA3
UKCA-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000MjSZHEA3
UKCA-Declaration for HouseholdContact GlobTek for more information
Morocco SDoC Declarationhttps://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0Oa000000MjSZHEA3
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0Oa000000MjSZHEA3
Prop 65 Statementhttps://en.globtek.com/prop-65-statement.pdf
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeDesktop/External
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor
CategoryICT / ITE / Medical Power Supply/Class 2/Household Power Supply
Input Voltage Range (V)100-240V~, 50-60Hz
Max Input Current (A)1.5A
Max Output Power Rating (W)90
Output Voltage Range (V)12-54
EfficiencyUSA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782
Ingress ProtectionIP41
Size (mm)149.3 x 62.8 x 34.0 +/-1.0
EnclosureUser-added image
Alternative housing with input cord clamp to prevent accidental removal of the power cord. Product PN# ends with suffix "CL"
User-added image
3D File Downloadhttps://www.globtek.com/dl/GTM96900-GTM961200-T3.igs
Rating Table
Preferred ratings shown below.
Custom output voltages available in 0.1V increment from the minimum voltage listed to the maximum voltage listed; contact sales.
Model Number (Final ordering #/Part No to be defined) VoltageAmps (A)Watts (W) LPS RFQ
GTM96900P9015-T3* 15690 N
GTM96900P9019-T3* 194.7389.87 N
GTM96900P9024-T3* 243.7590 N
GTM96900P9036-T3* 362.590 N
GTM96900P9048-T3_* -481.87590 N
GTM96900P9048-T3* 481.87590 N
GTM96900P9054-T3* 541.6689.64 N
GTM96900P8512-T3Z* 127.185.2 Y
GTM96900P9012-T3Z* 127.590 Y
GTM96900P9015-T3Z* 15690 Y
GTM96900P8128-9.5-T3* 18.54.3981.22 Y
GTM96900P9019-T3Z* 194.7389.87 Y
GTM96900P9024-T3Z* 243.7590 Y
GTM96900P9036-T3Z* 362.590 Y
GTM96900P9048-T3Z* 481.87590 Y
GTM96900P9054-T3Z* 541.6689.64 Y
GTM96900P8512-T3* 127.185.2
GTM96900P90VV.V-T3-XXXXCUSTOM CUSTOMCUSTOM CUSTOM
* (Final ordering #/Part No to be defined)
Specifications

Input

Input Voltage:Specified: 90-264VAC, Nameplate: 100-240VAC
     100% rated load current for 90-264VAC
       90% rated load current for 85-264VAC
     100% rated load current for 90-370VDC
Input Frequency:Specified: 47-63Hz, Nameplate: 50-60Hz
Power Factor:0.90 min. @ 230VAC, 0.97 min. @ 115VAC
No Load Input Power:< 150mW @ 115/230VAC
Inrush Current:< 65A @ 115VAC, < 130A @ 230VAC (cold start)
Efficiency:DoE Level VI and EU CoC Tier 2 compliant

Output

Turn-on Delay:1 second typ.
Output Regulation:± 4% (measured at output connector)
Line Regulation:± 0.5% typ. (measured at output connector, full load)
Ripple:1% or 200mV, whichever is greater (using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW, at output connector)
Startup Overshoot:5% max.
Transient Response:5% max. deviation, 1ms typ. recovery time (with 25% to 50% load step)
Hold-up Time:20ms min.
Power Indicator:Green LED
Switching Frequency:Variable, 25KHz - 125KHz, depending on load
Output Type:Z-suffix only: IEC62368-1 Limited Power Source (LPS), 8A and 100W max.

Protections

Input Protection:300VAC MOV transient suppressor, input line fusing
Over-Current Protection (Non-LPS Version):110 - 160% of rated output current, auto-restart
Over-Current Protection:
(LPS "Z" Version)
Overload limited to less than 8A and less than 100W, auto-restart
Short-Circuit Protection:Auto-restart
Over-Voltage Protection:110 - 135% (60V max for models rated 45 - 54V), full load condition, latched off, cycle AC to reset
Over-Temperature ProtectionOn-chip temperature sensor (integrated in primary-side switching controller), shut down at Tj = ~150°C, restart at Tj = ~140°C

Environmental

MTBF:1,500,000 hours @ 25°C ambient, full load (Telcordia SR-332, Issue 3)
Operating Temperature:-10°C to 40°C (full load)
Storage Temperature:-30°C to 80°C
Humidity:0% to 95% relative humidity, non-condensing
Altitude:5000m
Cooling:Convection
RoHS:Complies with EU 2011/65/EU and China SJ/T 11363-2006
Note 1:Regarding operating temperature
a. See below de-rating table for output power capability at alternate temperature
b. Extended low-end temperature range available as a custom option

Safety

Dielectric Withstand Voltage:4000VAC or 5656VDC from input to output
3000VAC or 4242VDC from input to earth (Class I models only)
Touch Current:Class I: 20µA max.
Class II: 70µA max.
Earth Leakage CurrentClass I: 300µA max.
Class II: N/A
Means of Protection:2 x MOPP
Output Isolation Options:Class I: C6 or C14 inlet (output negative tied to Earth contact)
Class II: C8 or C18 inlet
Class II FE: C6 or C14 inlet (output isolated from Earth contact)
Review isolation options by reading our white paper PSU Isolation and Identity.
Primary-to-Secondary Bridging Capacitors:Two IEC60384-14 Class Y1 capacitors
Earth Continuity Test:< 0.1Ω between earth pin (on AC inlet) and PCB termination point (Class I models only)
Compliant Standards:See listing at end of this datasheet for specific standards

EMC

Applicable Standards:Medical: EN60601-1-2, 4th edition
Emissions: EN55032, EN61000-6-3, EN61000-6-4, CISPR11, CISPR22
Immunity: EN55024, EN61000-6-1, EN61000-6-2
Conducted Emissions:Class B, FCC Part 15, Class B (with resistive load)
Radiated Emissions:Class B, FCC Part 15, Class B (with resistive load)
Harmonic Current Voltage Distortion:EN61000-3-2, Class A
Voltage Fluctuations/Flicker:EN61000-3-3
Electrostatic Discharge (ESD) Immunity:EN61000-4-2, 10KV contact discharge, 18KV air discharge
Radiated RF Immunity:EN61000-4-3, 10V/m 80-1000MHz,  3V/m 1-2.7GHz, 80% 1KHz AM
EFT/Burst Immunity:EN61000-4-4, 4KV/100kHz.
Line Surge Immunity:EN61000-4-5, 2KV differential, 4KV common-mode
Conducted RF Immunity:EN61000-4-6, 3VRMS, 80% 1KHz AM
Power Frequency Magnetic Field Immunity:EN61000-4-8, 3A/m
Voltage Dip Immunity:EN61000-4-11

Enclosure

Housing:High impact plastic, 94V0 polycarbonate, non-vented
Size:149.4 * 62.6 * 33.5mm, ± 1.0mm
AC Input Mechanical Options:C6, C8, C14, or C18 IEC inlet
Markings:Label and/or pad printed and/or laser-etched into case

Special Options

  1. IEC62368-1 Limited Power Source (LPS) version (add Z suffix)
  2. Reduced leakage current to meet IEC60601-1 Type-CF limits
  3. Improved EN61000-4-5 line surge immunity (3KV differential, 5KV common-mode)
  4. Reduced harmonic current levels for LED lighting (EN61000-3-2 Class C), available in three load ranges: 27-50W, 40-65W, and 57-90W
  5. Ruggedized construction with improved shock and vibration resistance
  6. Compliance to IPC-600, IPC-610, IPC-6012 Class 2 or 3
  7. Short term output surge capability for motors or other high peak current loads (non-LPS version only)
  8. Custom cordsets, special cordage and connector types
  9. Custom housing markings
  10. Custom housing/cordage colors
  11. Tightened output voltage tolerance
  12. Reduced output ripple level
  13. Reduced output power rating
  14. Low temperature option, down to -40°C
  15. Epoxy potted version "P2" or "P3" suffix, with flying wires or custom cables
  16.  "Back EMF" upgrade, for motor loads and other high inductance applications with reverse energy flow requirements
  17. Improved ingress protection (IP) rating

Output Connectors

 

 

Derating CurveUser-added image
Qty (ea.)/Carton20
Individual Box/Gift Box Size (mm)Egg Crate
Individual Box/Gift Box Color
Master Carton Size (mm)427 x 405 x 158
Gross Weight (kg)15.6
Label Width (mm)50.0
Label Height (mm)110.0
Input Configuration
DescriptionIEC 60320/C14 AC Inlet Connector, Class I, Earth GroundUser-added image
Mates with IEC 60320/C13 Plug

Optional Locking IEC60320 Receptable and cord option available on some models by request.:
User-added image

Standard International IEC 320/C13 Cordsets

Below are standard cordsets which are "not included" (unless stated above); these can be purchased separately or packaged with the power supply. Contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material.

 

Stock Power Supply Cords

Part Number/ LinkCountryPlugTerminationLength (mm)(Ft)
3021457F701(R)N. American (Type B)NEMA 5-15PIEC 320/C1321507
1191068F0701(R)N. American (Type B)NEMA 5-15P HospitalIEC 320/C1324598
2194272M5701-T(R)Argentina (Type I)IRAM 2073IEC 320/C1325008
5502022M5701A(R)Australian (Type I)AS3112 / 3 PRONGIEC 320/C1325008
204B4272M5701(R)Brazil (Type N)BRAZILIEC 320/C1325008
6023602M5701(R)China (Type I)CCC GR2099IEC 320/C1325008
G8014272M5701(R)Danish (Type K)AFSNIT SECTION 107-2-D1IEC 320/C1325008
23144272M5701-T(R)Europe (Type E)CEE 7/7IEC 320/C1325008
205IN4272M5701(R)                India (Type D)India IS 1293 (also known as IA16A3 or BS546)IEC 320/C1325008
208IN4272M5701(R)India (Type M)India IS 1293 (also known as IA16A3 or BS546)IEC320/C1325008
377C4272M5701(R)Israel (Type H)ISL 377CIEC 320/C1325008
23024272M5701(R)Italy (Type L)CEI 23-16/VIIIEC 320/C1325008
3003339F701(R)
[3x1.25mm2]

3003068F2701-HK(R) 

[3 x 2.0mm2]
Japan (Type B)JIS 8303 / 3 PINSIEC 320/C1325008
302J115J6F0701J(R)Japan / North America (Type B – 12A)JIS 8303 / 3 PINS and NEMA 5-15P (PSE and UL/CUL appr)IEC 320/C1318306
302J104J6F0701J(R)Japan / North America (Type B – 15A)JIS 8303 / 3 PINS and NEMA 5-15P (PSE and UL/CUL appr)IEC 320/C1318306
2313K3432M5701(R)Korea (Type F)KS C 8305IEC 320/C1325008
5804272M5701(R)Russia (Type F)GOST 7396IEC 320/C1325008
2084272M5701(R)South Africa (Type M)South Africa SABS164-1 (16A type)IEC 320/C1325008
23214272M5701(R)Switzerland (Type J)SEV 1011IEC 320/C1325008
3003322M5701(R)Taiwan (Type B)BSMIIEC 320/C1325008
PZ0800100-2M5BK13H(RUK, Hong Kong,Singapore, Gulf States (Type G)BS 1363AIEC 320/C1325008
7055002M5701A(R)InternationalIEC 320 C14-C13IEC 320/C1325008
Output Configuration
Common output connector options:
Click to add to your request.
L Type (Coaxial 5.5x2.5mm plug)
C Type (Coaxial 5.5x2.1mm plug)
K Type (Coaxial 3.5x1.3mm plug)
LL Type (5.5x2.5mm Locking 760k type)
CL Type (5.5x2.1mm Locking S761k type)
Magnetic Connector
L Type (Coaxial 5.5x2.5mm plug) C Type (Coaxial 5.5x2.1mm plug) K Type (Coaxial 3.5x1.3mm plug) LL Type (5.5x2.5mm Locking 760k type) CL Type (5.5x2.1mm Locking S761k type) Magnetic Connector
YL3 Type (KPPX-3P)
YL4 Type (KPPX-4P)
EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)
MSB Type (Micro USB)
Custom design
YL3 Type (KPPX-3P) YL4 Type (KPPX-4P) EJ1/2/3/4/5 (EIAJ RC-5320A type connectors) MSB Type (Micro USB) Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals
LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
 User-added image
 
Taiwan BSMI; http://www.bsmi.gov.tw/wSite/ct?xItem=4072&ctNode=816&mp=2 GTM96060-0606-1.0 (pending)

No Logo Applicable

CB for IEC 60601-1:2006/A1:2013+A12:2014 IEC 60601-1-11:2015

No Logo Applicable

CB for IEC 60335-1:2010 (Fifth Edition) incl. Corr. 1:2010 and Corr. 2:2011 + A1:2013

No Logo Applicable

CB for IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013

No Logo Applicable

CB for IEC61347-1:2015 + A1:2017 IEC61347-2-13:2014, A1:2016

No Logo Applicable

CB for IEC 62368-1:2014 (Second Edition)
User-added imageCCC Altitude up to 5000 m GB17625.1-2012, GB4943.1-2011, GB/T9254-2008
User-added image  Test standard: EN 55032: 2012+AC: 2013 EN 61000-3-2:2014 EN 61000-3-3:2013 EN 55024:2010 EN 60601-1-2:2015
User-added imageAudio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [UL 62368-1:2014 Ed.2] Audio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [CSA C22.2#62368-1:2014 Ed.2]
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
Conforms to AAMI STD.ES60601-1,IEC 60601-1-11
Certified to CAN/CSA STD.C22.2 NO.60601-1
Conforms to AAMI STD.ES60601-1,IEC 60601-1-11 Certified to CAN/CSA STD.C22.2 NO.60601-1
Conforms to UL STD. 1310
 Certified to CSA STD. C22.2 NO.223
Conforms to UL STD. 1310 Certified to CSA STD. C22.2 NO.223
Conforms to UL STD. 60950-1 
Certified to CSA STD C22.2 NO.60950-1
Conforms to UL STD. 60950-1 Certified to CSA STD C22.2 NO.60950-1
Conforms to UL STD. 62368-1
Certified to CSA STD C22.2 NO.62368-1
Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1
User-added image  Declaration ДС № ЕАЭС N RU Д-US.КА01.В.10453_19 Custom Union of Russia, Belarus and Kazakhstan http://www.globtek.com/redirect/?loc=gost-certificate-eac-declaration
User-added imageMedical Electrical Equipment - Part 1: General Requirements For Basic Safety And Essential Performance (R2012) [AAMI ES60601-1:2005 +C1;A2] [CSA C22.2#60601-1:2014 Ed.3] [AAMI HA60601-1-11:2015 Ed.2]
User-added imageInformation Technology Equipment Safety Part 1: General Requirements >Valid without technical revision: 01Jan2022< [UL 60950-1:2007 Ed.2 +R:14Oct2014]
User-added image
Class 2 Power Unit
Class 2 Power Units [UL 1310:2011 Ed.6 +R:12Dec2014] up to 5A Power Supplies With Extra-Low Voltage Class 2 Outputs [CSA C22.2 No.223:2015 Ed.3]
User-added imageCompliance of this power supply with FCC Part 15, Class B has been demonstrated with a standard output load. The FCC law stipulates that system-level testing is required to demonstrate compliance with the FCC emission limits with the actual system load.
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
IP41Ingress Protection: ?IP41 to IEC60529:2001 Protection against granular foreign bodies - Protected against vertically falling drops of water
User-added image
PRECAUCION: PARA USO EN EQUIPOS ELECTRONICOS SOLAMENTE
 
IRAM certificate DC-E-G71-005.1 to IEC 62368-1:2014
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[15V or less]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[DC15?30V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[DC30?60V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
 User-added image
 
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
LPSLimited Power Source if Z suffix on model number
LPSLimited Power Source if Z suffix on model number 62368
No Logo Malaysia ST Release Letter GTM41133 GTM96900P; GTM961200P T2 T3(A) IEC60950-1(Ed.2): 2005 + A1:2009 + A2:2013 No logo
User-added image
 
Morocco SDoC declaration http://www.globtek.info/certs/Morocco%20SDoC%20Declaration/
User-added imageNOM MEXICO -ANCE FOR GTM96900P-T3 12,15,18,19,24,36,48 and 54V only
Patent pendingPatent pending
User-added imageRCM certificate SAA-170646-EA; Australia and New Zealand Regulatory Compliance, Mark (http://rcm.standards.org.au/rcmfaq/rcmfaq.htm)
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added image
 
S-Mark Certificate EN 60601-1:2006 + A1:2013 + A12:2014 EN 60601-1-11:2015 (http://www.intertek.com/marks/s/)
User-added image
 
S-Mark Certificate EN 62368-1:2014 + A11 (http://www.intertek.com/marks/s/)
User-added image
 
S-Mark Certificate EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011+A2:2013 (http://www.intertek.com/marks/s/)
User-added image
Serial Number Information
User-added imageSingapore 190461-12 GTM96900P9024-T3
User-added imageUKCA Certification
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageUL1310 Warning Label Up To 36 Volts with plugs
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample Request Distributor Stock (Click to order)
1722009-48.01.875D-Sub 3W3 connector, solder, with FEMALE contacts or equal
1058541-48.01.875Stripped 30 +/-1mm; not tinned; with wire end sleeves, red (insulated type)
1636360-48.02.5Stripped 30 +/-1mm; not tinned; with wire end sleeves, red (insulated type)
TR9CE7500YL4-IM(R6B)12.07.54 Pin Locking Kycon or Equal 3
35880712.07.5T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit)
36618712.07.5Phoenix 1805410 2 pos 3.5mm or Dinkle EC350VM-5671-02P, ***NO OTHER ALT ***
161207712.07.54 Pin Locking Kycon or Equal
151306512.07.08Switchcraft S10KS17 locking, sealed high amperage power plug
58964312.07.084 Pin Locking Kycon or Equal
143923312.07.5Amphenol T3361-001, no equivalent
143923212.07.5Amphenol T3361-001, no equivalent
88942612.07.5DC Power connector, locking, 5.5*2.5mm, 12mm insertion depth; Equiv to 761K; mates with L712A, PCL712A
87796312.07.5Female Barrel 5.5*2.5*9.5mm with internal Spring Clip and Locking Notch or Equal
81851112.07.084 Pin Kycon Plug or Equal, NON-LOCKING TYPE
142168312.07.54 Pin Locking Kycon or Equal
TR9CE7500FILRPNIMR6B12.07.5Female Barrel 5.5*2.5*11mm, Right Angle with Spring Clip & Locking Notch, Barrel rated for 10A 88
35880612.07.5Female Barrel 5.5 * 2.1 * 11 mm with internal Spring Clip and Locking Notch or Equal; Barrel rated for 10A
TR9CE7080CPCIMR6BLPS12.07.08Female Barrel 5.5 * 2.1 * 11 mm with internal Spring Clip and Locking Notch or Equal; Barrel rated for 10A 18
TR9CE7080LPCIMR6BLPS12.07.08Female Barrel 5.5 * 2.5 * 11 mm with internal Spring Clip and Locking Notch or Equal; Barrel rated for 10A 20
56156612.07.5Molex Mini-Fit Jr.™ Housing #39-01-2040 & Terminal # 538-460-55-0007 or equal
109962712.07.54 Pin Locking Kycon or Equal
25271212.07.5Switchcraft S10K or equivalent
39744812.07.5Phoenix 1714977, 2 position connector or equivalent
26156512.07.5Kycon # KPPX-3, 3 pin Snap Locking or Equal
TR9CE7500LCP-IM(R6B)12.07.5Female Barrel 5.5 * 2.5 * 11 mm with internal Spring Clip and Locking Notch or Equal; Barrel rated for 10A 15
47894012.07.5HOSIDEN P/N: TCP8927-53-1100 QUICK LOCK type or equivalent::
22760212.07.5Switchcraft 761KS12 connector, 5.5x2.5x12mm with thumb screw, sealed, no substitute
85633012.57.2Switchcraft S10KS15 locking, sealed high amperage power plug
158747413.66.61Female Barrel 5.5*2.5*9.0mm, Right Angle WITH internal Spring Clip & Locking Notch or Equal
25495915.06.0Female Barrel 5.5 * 2.5 * 9.5mm with internal Spring Clip and Locking Notch or Equal
142553615.06.0Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal; Barrel rated for 10A
177507315.06.0BARREL PLUG, RIGHT ANGLE, 7.4mm (Outside Diameter) x 5.08mm (Inside Diameter) with center pin (OD 0.6mm)
23676115.06.0Female Barrel 5.5 * 2.5 * 9.5mm with internal Spring Clip and Locking Notch or Equal
24795115.06.0Amphenol P/N: 206060-1, contact P/N: 66101-4
38117715.06.0Female Barrel 5.5 * 2.5 * 11mm No internal Spring Clip nor Locking Notch or Equal
35880815.06.0T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit)
160272315.06.04 Poles M12 Connector
TR9CG6000LCP-IM(R6B)15.06.0Female Barrel 5.5 * 2.5 * 11 mm with internal Spring Clip and Locking Notch or Equal; Barrel rated for 10A 40
60233315.06.0Amphenol P/N: 206060-1, contact P/N: 66101-4
67964515.06.0Female Barrel 5.5 * 2.1 * 13 mm with internal Spring Clip and Locking Notch or Equal; Barrel rated for 10A
66705816.05.625Female Barrel 5.5 * 2.5 * 9.5mm with internal Spring Clip and Locking Notch or Equal
35880918.05.0T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit)
142533118.54.39Switchcraft 3 position sealed circular Female EN2C3F20DC plug or equal
35881019.04.73T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit)
TR9CZ4730L9PCIMR6LPS19.04.73Female Barrel 5.5*2.5*9.5mm with internal Spring Clip and Locking Notch or Equal 179
159153419.04.73Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
160272119.04.73Female Barrel 5.5*2.5*9.5mm with internal Spring Clip and Locking Notch or Equal
94702019.04.7Female Barrel 5.5*2.5*9.5mm with internal Spring Clip and Locking Notch or Equal
27666419.04.73Female Barrel 5.5*2.5*12mm, Right Angle with internal Spring Clip nor Locking Notch or Equal
158645719.04.73Female Barrel 5.5*2.5*13mm, Right Angle High Retention Internal Spring Clip & Locking Notch
175151319.04.73Female Barrel 5.5*2.1*9.5mm with internal Spring Clip and Locking Notch or Equal
TR9CZ4737YL4-IM(R6B)19.04.734 Pin Locking Kycon or Equal 19
60059120.04.5Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
55093320.03.0Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
60059520.04.5USB Type-C Connector
58566220.04.5Lenovo Square Slim Connector
175251924.03.75Mini-Con-X Conxall/Switchcraft assembled connector 6380-2SG-311
122082124.03.75Female Barrel 5.5*2.1*11mm WITH internal Spring Clip and Locking Notch or Equal
129591124.03.8ROJ 25 +/- 3mm; stripped and tinned 10mm +/- 2mm
149773924.03.75DC Power connector, locking, 5.5*2.5mm, 12mm insertion depth; Equiv to 761K; mates with L712A, PCL712A
159011924.03.75T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit)
161209724.03.755 Pin 180° Male DIN Plug or Equal
163780724.02.5Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
20427024.03.75Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
99149224.03.75ROJ 25 +/- 3mm; stripped and tinned 10mm +/- 2mm
22595824.03.75MOLEX Mini-fit 6 circuit receptacle HOUSING P/N:39-01-2060 Crimp, 4.2mm pitch or Equal. Color natural.
TR9CI3750LCPCIM(R6B)24.03.75Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal 20
23513724.03.75Female Barrel 5.5*2.1*11mm WITH internal Spring Clip and Locking Notch or Equal
26452224.03.75Kycon # KPP-3P, DC Power Connectors 3P Power Plus Snap and Lock or Equal
TR9CI3750CCP-IM(R6B)24.03.75Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal 45
35881224.03.75T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit)
39742724.03.75Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
119014924.03.75Female Barrel 5.5*2.5*11mm, Right Angle with Spring Clip & Locking Notch or Equal
164737024.03.754 Pin Locking Kycon or Equal
97092224.03.8Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
TR9CI3750LCPIMR6BLPS24.03.75Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal 98
50611524.02.5Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
53791024.03.7DC Power connector, locking, 5.5*2.5mm, 12mm insertion depth; Equiv to 761K; mates with L712A, PCL712A
55092724.01.87Female Barrel 5.5*2.1*9.5mm with internal Spring Clip and Locking Notch or Equal
58964224.03.754 Pin Locking Kycon or Equal
60410024.03.8Amphenol RG8X 112533 no equivalent
110649524.03.75Switchcraft 761KS15 connector, 5.5x2.5x12mm with thumb screw, sealed, no substitute
55208124.03.8ROJ 25 +/- 3mm; stripped and tinned 10mm +/- 2mm
56438124.03.8Stripped 50 +/-5mm; Tinned 9.5 +/- 2mm or Equal
TR9CI3750CPCIMR6BLPS24.03.75Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal 38
TR9CI3750T00IMR6BLPS24.03.75T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit) 21
78388424.03.75Female Barrel 5.5*2.5*9.5mm, Right Angle with internal Spring Clip & Locking Notch or Equal
80991024.03.75Female Barrel 5.5*2.5*9.5mm, Right Angle with internal Spring Clip & Locking Notch or Equal
81850924.03.75Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
91965324.03.75Female Barrel 5.5*2.5*9.5mm, Locking or Equal
94961424.03.8Female Barrel 5.5*2.5*12.0mm, Right Angle with internal Spring Clip & Locking Notch or Equal
TR9CI3750LLP4CR6BLPS24.03.75DC Power connector, locking, 5.5*2.5mm, 12mm insertion depth; Equiv to 761K; mates with L712A, PCL712A 10
102597228.03.21Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
185160528.03.21Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
103956928.03.21T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit)
103850328.03.21Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
138902030.03.0Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
TR9CR3000T00-IM(R6B)30.03.0T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit) 12
49965130.03.0Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
37648335.02.57Female Barrel 5.5*2.5*9.5mm with internal Spring Clip and Locking Notch or Equal
56479036.01.25Female Barrel 5.5*2.1*9.5mm with internal Spring Clip and Locking Notch or Equal
53962436.01.66Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
175699648.01.8754 Pin Locking Kycon or Equal
177302948.01.25Stripped 25+/-5mm, Tinned 8+/-1mm or Equal
23513448.01.8754 Pin Locking Kycon or Equal
56196948.01.875MOLEX P/N:43025-0800 Micro-fit 3.0 (8) circuit connector housing with 2pcs MOLEX TERMINAL P/N:430-300-0001 OR EQUIVALENT. CONNECTOR IS OVERMOLDED ONTO OUTPUT CABLE
35881448.01.875T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit)
118146848.01.8754 Pin Locking Kycon or Equal
TR9CX166T00-IM(R6B)54.01.66T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit) 13
39753854.01.66Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
What is an IEC 60601-1 medical grade rated power supply AC adapter?

An IEC 60601-1-2 medical grade rated power supply AC adapter converts input line voltage from the wall to a lower voltage, typically DC, which is used to operate and end use piece of medical equipment. IEC 60601-1-2 medical grade power supply AC adapters are typically housed in a plastic enclosure and are available with both 2 and 3 prong input options. power supplies are also available as open frame for use inside of medical equipment. These AC to DC converters are designed in accordance with international medical standards and provide for compliance with certain aspects of them which differs from generic information and communication technology equipment power supplies.

Why is my medical grade IEC 60601-1 power supply certified to IEC 60601-1 3rd Edition while the latest standard is IEC 60601-1 4th Edition?
IEC 60601-1 has different sections in specifications for safety and EMI/EMC. The latest revision of the safety portion of  IEC 60601-1 is 3rd Edition while for EMI/EMC the latest revision is 60601-1-2, 4th Ed. 

What is the effective date of 60601-1-2, 4th Ed?
60601-1-2, 4th Ed. was effective on December 31, 2018.

What's the difference between an IEC 60950-1 and IEC 60601-1 medical grade rated power supply?

IEC 60950-1 and IEC 60601-1-2 power supplies are both AC to DC converters and may be either internal or external but are designed to different specifications to match the end system specifications. While the basic performance behaviors are similar such as input and output voltages and mechanical configurations, there are many differences as well. Some of the key differences are that medical IEC 60601 medical grade AC to DC adapters are able to withstand a higher dielectric withstand voltage and must have lower leakage current.  There are many other differences and also considerations to consider depending on the end use application.  

What MOOP and MOPP?
Medical devices must incorporate one or more Means of Protection (MOPs) to isolate patients and operators from the risks of electrocution. A Means of Protection (MOPs)  can be safety insulation, a protective earth, a defined creepage distance, or an air gap or other protective impedance. These can be used in various combinations. IEC 60601-1 3rd edition differentiates between the risk to patients and the risk to operators. A MOP can therefore be classified as Means of Patient Protection (MOPP) or a Means of Operator Protection (MOOP). The main difference between one MOOP and one MOPP is primarily one of permissible creepage distance. Both requirements are satisfied using Basic insulation. To achieve 2 x MOPP qualification the isolation test is particularly demanding at 4000 Vac and the creepage distance of 8mm is twice that required for one MOPP. 

What is a BF and CF rated an IEC 60601-1-2 medical grade rated power supply AC adapter and what is the difference?

Medical grade power supplies and AC to DC adapters are categorized into one of three applied parts types: body type (B), body floating type (BF), and cardiac floating type (CF). These applied parts require specific attributes such as isolation voltage, creepage and leakage current. Floating refers to an ungrounded power supply, Class II, that is not referenced to another output and is fully isolated. Type B refers to devices that operate within the patient's vicinity, as described in IEC 60601-1 as six feet around a patient's chair or bed and do not touch the patient electronically and are grounded. These devices include operating room lighting, hospital carts and beds, automated dispensers of medication and supplies, and diagnostic equipment like x-ray machines. Type BF devices deliver electrical energy signals to or from the patient such as electrosurgical devices, endoscopes, and electrical vital sign monitors like thermometers. Type CF devices are similar to BF, except they supply power to devices connected to the heart, such as a defibrillator, external pacemaker or intracardiac ECG electrodes and Type CF requires a higher degree of protection against electrical shock than BF types.  
 

Is level VI efficiency required for power over Ethernet?

According to the department of energy of the United States,  An EPS may be considered a Class A EPS if it connects to the end-use application using any type of electrical connection, cable, cord, or other wiring, including both removable and hard-wired connections. An Ethernet cable would meet these criteria, so an EPS that connects to the end-use product via an Ethernet cable would still be considered a Class A EPS and would be subject to the applicable energy conservation standards if it meets the other  five criteria of a Class A EPS. In general all power over ethernet power supply adapters meet all criteria and are required to be level VI efficiency.

What is a IEC 62368-1:2018 power supply?

IEC 62368-1:2018 is applicable to the safety of electrical and electronic equipment within the field of audio, video, information and communication technology, and business and office machines with a rated voltage not exceeding 600 V. This is a product safety standard that classifies energy sources, prescribes safeguards against those energy sources, and provides guidance on the application of, and requirements for, those safeguards. The prescribed safeguards are intended to reduce the likelihood of pain, injury and, in the case of fire, property damage. An IEC 62368-1 rated AC to DC converter or power supply is a power supply that has been tested to and certified to comply with the said standard.

Did IEC 62368-1 power supplies replace IEC60950-1 power supplies?

On December 20, 2020 the safety standards that historically have applied to information technology equipment and audio video equipment, IEC 60065 and IEC 60950-1,transition to IEC 62368-1. In North America ETL and UL 60950-1 certifications will continue to stay valid and may continue to be used until further notice. 

What is the difference between an IEC 62368-1 and a IEC 60950-1 power supply?

While the structure and contents of the standards are very different in general most products that previously complied with IEC 60950-1 comply with the latest standard IEC 62368-1 with little or no modification.

Will my IEC60950-1 power supply remain available?

GlobTek will continue to manufacture and supply IEC 60950-1 power supplies indefinitely until further notice.

What is Level VI Efficiency?

The numerals I to VI are an International Efficiency Marking Protocol which allows manufacturers to designate the efficiency performance of a product. This performance is based on the measurement of the operating energy efficiency and no-load power consumption of external power supplies or AC DC adapters tested at different load levels. The no-load power consumption refers to the amount of power that an external power supply draws even when the application is turned off or disconnected.

Is Level VI Efficiency required?

Level VI efficiency is mandated in certain countries and regions for certain products or certain applications.

What is the Eco-design Directive 2009/125/EC?

The Eco-design directive put into law in Europe the latest requirements for energy efficiency and conservation for AC DC adapters and external power supplies.

How Does an AC-DC Adapter Work?

The AC to DC adapter or external power supply consists of a power supply which is enclosed in a housing similar to an AC plug, hence the term plug type, wall plug in, plug-in or plugtop power adapter. The power supply is plugged into the mains socket and the AC Voltage is then converted by the AC to DC adapter power supply into a DC voltage that is fed into the appliance via the output cable connection.

Request Info

Model

Call
Email
💬
Text
💁
Chat
?
Request a Quote
Can we help you?
Can we help you?