Regulated Switchmode AC-DC Power Supply AC Adaptor
Category
ICT / ITE / Medical Power Supply/Class 2/Household Power Supply
Input Voltage Range (V)
100-240V~, 50-60 Hz
Max Input Current (A)
0.6 A
Max Output Power Rating (W)
18
Output Voltage Range (V)
5-48
Efficiency
V
Ingress Protection
IP52
Size (mm)
74*44*34
Enclosure
Rating Table
Model Number (Final ordering #/Part No to be defined)
Voltage (V)
Current (A)
Power (W)
RFQ
GTM41080-1807-2.0 .*
5
3
15
GTM41080-1511-1.0*
10.15
1.5
15.23
GTM41080-1007-2.0*
5
2
10
GTM41080-1207-1.0*
6
2
12
GTM41080-1830-11.0*
19
0.94
17.86
GTM41080-1507-1.0*
6
2.5
15
GTM41080-1811-2.0*
9
2
18
GTM41080-1817.9-2.9*
15
1.2
18
GTM41080-1817.9-5.9*
12
1.5
18
GTM41080-1830-12.0*
18
1
18
GTM41080-1830-6.0*
24
0.75
18
GTM41080-1838-2.0*
36
0.5
18
GTM41080-1848*
48
0.375
18
GTM41080-1811-1.7*
9.3
1.94
18.04
GTM41080-1807*
7
2.57
17.99
GTM41080-1811*
11
1.67
18.37
GTM41080-1817.9*
17.9
1
17.9
GTM41080-1830*
30
0.6
18
GTM41080-1838*
38
0.47
17.86
GTM41080-1507-1.8*
5.2
3
15.6
GTM41080-1507-1.5*
5.5
2.72
14.96
GTM41080-1507-0.5*
6.5
2.76
17.94
GTM41080-1817.9-2.0*
15.9
1.13
17.97
GTM41080-1507-2.0*
5
3
15
GTM41080-1807-2.0*
5
3.6
18
GTM41080-1838-6.0*
32
0.56
17.92
* (Final ordering #/Part No to be defined)
Specifications
A) ELECTRICAL SPECIFICATIONS: 01. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac 02. Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz 03. Output Regulation: +/- 5% measured at the output connector* 04. Line Voltage Regulation: +/- 1% typical measured at full load 05. Output Ripple (Vp-p): +/-1% or 150 mV whichever is greater, measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with 10 uf electrolytic capacitor connected at the end of the output connector at nominal line 06. Turn-ON/OFF Overshoot: 5% maximum, 1 mS typical recovery time for 25% to 50% step load 07. Turn-ON Delay: 3000 mS, maximum @ full load, nominal line 08. Hold-Up Time: 8 mS typical @ nominal input voltage and full load 09. Inrush Current: 30A maximum cold start @ 240Vac input 10. Switching Frequency: 65 KHz typical 11. Efficiency: Compliant with Worldwide Level V standards. 12. No Load Standby Power: <0.3 W
B) PROTECTION 01. Over-Voltage: Electronically Protected Zener clamp across the output 02. Short Circuit: Electronically Protected unit will auto recover upon removal of fault 04. Input Protection: Input line and neutral fusing
C) SAFETY 01. Dielectric Withstand Voltage: 5656Vdc from primary to secondary 02. Earth Leakage Current: N/A for Class II units, there is no PE Ground pin, so Earth Leakage current is not measured 03. Touch Current: Maximum allowed values: 100uA NC(Normal condition) 500uA SFC(single fault condition) 04. Means of Protection: 2 x MOPP 05. Primary to Secondary Bridging Capacitor: (2) * Y1 type capacitors in series
D) OTHER: 01. MTBF: 200,000 Hours @ 25°C ambient temperature 02. Operating Temperature: 0°C to 40°C ambient temperature 03. Humidity: 0% to 90% relative humidity 04. Storage Temperature: -10°C to 80°C 05. Cooling: Convection 06. ROHS 2: Complies with EU 2011/65/EU and China SJ/T 11363-2006
E) ENCLOSURE 01. Housing: High impact plastic, 94V0 polycarbonate, non-vented 02. Size: 43.5 x 74.0 x 35.3 +/-1.0 mm 03. Markings: Label and/or Pad Printed and/or Molded in the case
* 5Vdc USB output connector power supplies, which use the Micro-B or C-type style connector, have a max output voltage regulation specification of +/-8% (4.6V to 5.4V range).
INPUT CONNECTOR: Q-Socket (below are available blades configurations which are "not included" (unless stated above); can be purchased separately, package with power supply or as a separate "Q-KIT" if specified
01. United States / Canada / Japan NEMA 1-15P/ IEC PLUG Type A [WORKS IN PLUG B] configuration: NA 2 blades, Class II; US/CA/JP P/N: Q-NA(R) 02. Australian AS 3112 configuration: SAA 2 blade/ IEC TYPE I, Class II; AU P/N: Q-SAA(R) 03. UK BS 1363 configuration: UK 3 blade with dummy Ground/ IEC TYPE G, Class II; GB P/N: Q-UK(R) 04. European CEE 7/16 configuration: Europlug 2 pins/ IEC TYPE C [WORKS IN TYPE E&F], Class II; EU P/N: Q-EU(R) 05. Korean KS C8305 configuration: 2 pins/SIMILAR TO IEC TYPE C, Class II; KR P/N: Q-KR(R) 06. Argentina IRAM 2073 configuration: 2 blades/SIMILAR TO IEC TYPE I; AR P/N: Class II Q-AR(R) 07. China GB 2099 configuration: 2 blades/SIMILAR TO TYPE A, Class II; CN P/N:Q-CN(R) 08. India IS 1293 6A/BS546 configuration: 5A, 3 pins with Dummy Ground, Class II/IEC TYPE D; IN P/N: Q-IN(R) 09. IEC60320/C18 Inlet, Class II; P/N:Q-C18(R) 10. Brazilian NBR6147 configuration: 2 pins, Class II;SIMILAR TO IEC TYPE C BR P/N: Q-BR(R) 11. South Africa SABS164-1 and India IS 1293, IS694, 16A type plug, 3 round prongs, Class II + dummy ground, IEC TYPE M P/N: Q-SANS164-1-16A(R) 12. South Africa SABS164-4, 3 round prongs with a notched prong @ 0º, Class II + dummy ground, IEC TYPE M Red, P/N: Q-SANS164-4C-16A(R) 13. South Africa SABS164-4, 3 round prongs with a notched prong @ -53º, Class II + dummy ground, Blue, IEC TYPE M, P/N: Q-SANS164-4L-16A(R) 14. South Africa SABS164-4, 3 round prongs with a notched prong @ +53º, Class II + dummy ground, Black,IEC TYPE M P/N: Q-SANS164-4R-16A(R)
Contact GlobTek for your specific requirements or custom solutions.
Approvals
Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.
Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.
Logo
Description
Medical 4th Ed.
EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
UKCA Certification
No Logo Applicable
CB to 60335-1 5th Edition (Safety of Household and Similar Electrical Appliances, Part 1: General Requirements) CB Report/ Certificate IEC 60335-1:2010 Up to 36 volts only
No Logo Applicable
CB to 60601-1 3rd Edition 2xMOPP, CB Certificate: IEC 60601-1:2005, CB report: IEC 60601-1: 2005 + CORR. 1 (2006) + CORR. 2 (2007) and EN 60601-1:2006
Certification # TC RU AR46.B.75423 Custom Union of Russia, Belarus and Kazakhstan
Japan: Voluntary Control Council for Interference (VCCI)
Indoor Use Only - Mark is on the label or Molded in the case
WEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
JAPAN TUV Rheinland-PSE GlobTek Inc to J60950-1(H26) , J55022(H22),J3000(H25).Please follow the procedure listed in the following link for proper import to Japan: http://en.globtek.com/importing-to-japan.php.
cETLus-Cert-4007497 ANSI/AAMI ES60601-1:2005 with AMD C1: 2009, AMD C2: 2010 and CAN/CSA-C22.2 No. 60601-1 2008 with COR 2:2011+ANSI/AAMI HA60601-1-11 Ed:1
RoHS
Specifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
Book 60335 up to 36 Volts
Fuse 60335 T1.6A 250VAC Up to 36 volts
60601-1 3rd Operating Instructions
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
Conforms to ANSI/AAMI ES 60601-1:2005 Cert.to CAN/CSA Std. C22.2
cETLus ANSI_AAMI ES60601-1_2005
CHINA SJ/T 11364-2014, China RoHS Chart: http://www.globtek.com/pdf/F-GT-DJD-8.4.1-006%20China%20RoHS%20Declaration%205-20-22.pdf
Class 2 Power Unit
cETLus-Cert 4007497 UL1310 Recognized Component up to 42.4 volts
IP52
Ingress Protection: ?IP52 to IEC60529:2001 Protected against dust - limited ingress (no harmful deposit) and Protected against direct sprays up to 15 degrees from the vertical
No Logo
CB Certificate IEC 60950-1:2005 (2nd Edition), Am 1: 2009, CB report IEC 60950-1:2005 (2nd Edition), Am 1: 2009 and EN 60950-1:2006 + Am 1:2010 + Am 11:2009 + Am 12:2011
CCC to GB4943.1-2011; GB/T9254-2008 GB17625.1-2012, Tropical <2000
No Logo Applicable
CB to 60335-1:2010 (Fifth Edition) incl. Corr. 1:2010 and Corr. 2:2011 + A1:2013
CE Mark: tested to comply with EN 60601-1-2:2015 Medical electrical equipment Part 1-2: - Mark is on the label or Molded in the case
CE Certification CE Mark: tested to comply with EN 55032.2012+AC.2013 EN 61000-3-2.2014 EN 61000-3-3.2013 EN 60601-1-2.2015 EN 55024.2010
Bureau Of Indian Standards for GTM41080-1817.9-5.9, GTM41080-1507 -2.0, GTM41080-1507-1.0, GTM41080-1811-2.0, GTM41080-1817.9-2.9, GTM41080CC1017.9-2.9, GTM41080-1830-12.0, GTM41080-1830-6.0, GTM41080-1838-2.0, GTM41080-1848
Compliance of this power supply with FCC Part 15, Class B has been demonstrated with a standard output load. The FCC law stipulates that system-level testing is required to demonstrate compliance with the FCC emission limits with the actual system load.