GTM91110P150VV-F-S Open Frame/Internal ICT / ITE / Medical Power Supply Datasheet
Request Information
Download PDF
GTM91110P150VV-F-S Image | ||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Model Image | ![]() | |||||||||||||||||||||||||||||||||||||||||||||||||
Information | ||||||||||||||||||||||||||||||||||||||||||||||||||
Model Number | GTM91110P150VV-F-S | |||||||||||||||||||||||||||||||||||||||||||||||||
Description | GTM91110P150VV-F-S, ICT / ITE / Medical Power Supply, Open Frame/Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, Molex 26-60-4030 3 Position Header Pin 1: Line, Pin 2: Removed, PIN 3: Neutral, Output Rating: 150 Watts, Power rating with convection cooling (W) , 12-55V in 0.1V increments, Approvals: EAC; cETLus; Book 60601; CB 60601-1; CB 60950; CE; CE; cETLus 60601-1 3rd; China RoHS; Class I; FCC; RoHS; SIQ; SIQ; Ukraine; VCCI; WEEE; cETLus; | |||||||||||||||||||||||||||||||||||||||||||||||||
Agency Documents | http://www.globtek.info/certs/GTM91110P/ | |||||||||||||||||||||||||||||||||||||||||||||||||
CE EC-Declaration for Medical | Contact GlobTek for more information | |||||||||||||||||||||||||||||||||||||||||||||||||
CE EC-Declaration for Industrial/Commercial/ITE | https://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000MEMMcEAP | |||||||||||||||||||||||||||||||||||||||||||||||||
CE EC-Declaration for Household | Contact GlobTek for more information | |||||||||||||||||||||||||||||||||||||||||||||||||
UKCA-Declaration for Medical | Contact GlobTek for more information | |||||||||||||||||||||||||||||||||||||||||||||||||
UKCA-Declaration for Industrial/Commercial/ITE | https://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000MEMMcEAP | |||||||||||||||||||||||||||||||||||||||||||||||||
UKCA-Declaration for Household | Contact GlobTek for more information | |||||||||||||||||||||||||||||||||||||||||||||||||
Morocco SDoC Declaration | https://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0Oa000000MEMMcEAP | |||||||||||||||||||||||||||||||||||||||||||||||||
RoHS/RoHS3 Declaration | https://www.globtek.com/pdf/rohs_cert/a0Oa000000MEMMcEAP | |||||||||||||||||||||||||||||||||||||||||||||||||
Prop 65 Statement | https://en.globtek.com/prop-65-statement.pdf | |||||||||||||||||||||||||||||||||||||||||||||||||
REACH Declaration | https://www.globtek.com/pdf/iso_certificates/REACH.pdf | |||||||||||||||||||||||||||||||||||||||||||||||||
Conflict Minerals Declaration | https://www.globtek.com/pdf/conflict-minerals.pdf | |||||||||||||||||||||||||||||||||||||||||||||||||
Model Parameters | ||||||||||||||||||||||||||||||||||||||||||||||||||
Type | Open Frame/Internal | |||||||||||||||||||||||||||||||||||||||||||||||||
Technology | Regulated Switchmode AC-DC Power Supply AC Adaptor | |||||||||||||||||||||||||||||||||||||||||||||||||
Category | ICT / ITE / Medical Power Supply | |||||||||||||||||||||||||||||||||||||||||||||||||
Input Voltage Range (V) | 100-240V~, 50-60 Hz | |||||||||||||||||||||||||||||||||||||||||||||||||
Max Input Current (A) | 4.0A | |||||||||||||||||||||||||||||||||||||||||||||||||
Max Output Power Rating (W) | 150 | |||||||||||||||||||||||||||||||||||||||||||||||||
Output Voltage Range (V) | 12-55 | |||||||||||||||||||||||||||||||||||||||||||||||||
Efficiency | N/A | |||||||||||||||||||||||||||||||||||||||||||||||||
Ingress Protection | ||||||||||||||||||||||||||||||||||||||||||||||||||
Size (mm) | 127x76.2x43 1U | |||||||||||||||||||||||||||||||||||||||||||||||||
Enclosure | Label 1 Position Label 1 on top of Transformer Label 2 Material: White art paper with Black nomenclature and is attached on top of CX1 Label 3 Material: White art paper with Black nomenclature and is attached on side of CX1 | |||||||||||||||||||||||||||||||||||||||||||||||||
Rating Table | ||||||||||||||||||||||||||||||||||||||||||||||||||
* (Final ordering #/Part No to be defined)
| ||||||||||||||||||||||||||||||||||||||||||||||||||
Specifications | ||||||||||||||||||||||||||||||||||||||||||||||||||
A) ELECTRICAL SPECIFICATIONS: 01. Input Voltage: Specified 90-264 Vac, Nameplate rated 100-240 Vac 02. Input Frequency: Specified 47-63 Hz, Nameplate rated 50/60 Hz 03. Inrush current: Cold start @ 25°C, 40A @ 115Vac, 80A @ 230Vac 04. Efficiency: 85% to 90% typical at full load, 120-240Vac input 05. Power factor: 0.98 typical at full load, 230Vac input 06. Turn on delay: 5 Seconds maximum, (3 seconds max option) 07. Load regulation: ± 1% Measured at the connector side 08. Line regulation: ± 0.2% Measured at the connector side 09. Output Ripple protection (Peak to Peak): +/-1% maximum of nominal output voltage measured at 20 MHz bandwidth with 0.1µf ceramic capacitor in parallel with a low impedance 47 µf electrolytic capacitor located 200mm from the end of the output connector 10. Turn on/off overshoot: 5% Maximum, 1mS recovery time 11. Hold up time: 8 mS @ 300W load, 10mS@200W load, 16mS@150W load at 115Vac input 12. Transient response: 2% Maximum deviation, returns to initial condition in 3 ms max for 25% load step, from 10% to 100% of rated load 13. Remote sense (optional): compensates for up to 0.5V voltage drop in output wiring. Power supply will operate correctly, with or without remote sense pins hooked up. 14. Auxillary Output: For forced air fan 12V @ 250mA, if convection cooled 12V @ 150mA. Other output voltages and current ratings from 5V to 24V available, contact factory for availability. 15. Indicator: Green LED for output presence B) PROTECTION 01. Input Protection: Input line fusing and 300Vac MOV 02. Short circuit: Protected. Unit will autorecover upon removal of short 03. Overload protection: Autorecover upon removal of overload 150W, 175% - 210% of nominal power rating 200W, 130% - 160% of nominal power rating 240W, 110% - 130% of nominal power rating 300W, 110% - 130% of nominal power rating 04. Over voltage: Protected at 110- 140% of nominal output voltage, latched type. AC cycling required to restore output. Autorecovery type OVP is an option, contact factory for availability. 05. Fan output protection: 3 Pin Linear Regulator, short circuit proof C) SAFETY 01. Dielectric Withstand Voltage: 4000Vac or 5656Vdc from input to output, On Class I models, 2500Vac or 3535Vdc from input to earth 02. Earth Leakage Current: Class I Input Models: Does not exceed 500uA Class II Input Models: Does not apply 03. Touch Current: Does not exceed 100uA, output terminations to earth 04. Output terminations rated as SELV, and Means of Operator Protection D) OTHER: 01. MTBF: 200,000 Hours @ 25°C ambient temperature 02. Operating Temperature Range: -10°C to 50°C @ 100% output power rating -10°C to 70°C @ 50% output power derating 03. Cooling: Open Frame 150W Series: Convection Open Frame 240W and 300W Series: 20 CFM Forced Air Cooling Perforated Plastic Housing 200W Series: 20 CFM Forced Air Cooling, with convection cooling 50% derated (100W) output capability. 04. Relative Humidity: operating 0% to 90% Non-condensing 05. Storage Temperature: -30°C to 85°C 06. Altitude: up to 2000 meter 07. Random vibration/transient drop: MIL-STD 810E E) MECHANICAL FORMAT: 150W, 240W and 300W Open Frame version Size: 127*76.2*43 mm Weight: 470 grams 200W Perforated Plastic Enclosure version Size: 140*87.6*51.9 mm Weight: 620 grams | ||||||||||||||||||||||||||||||||||||||||||||||||||
Derating Curve | ||||||||||||||||||||||||||||||||||||||||||||||||||
Qty (ea.)/Carton | 60 | |||||||||||||||||||||||||||||||||||||||||||||||||
Individual Box/Gift Box Size (mm) | 135*85*60 | |||||||||||||||||||||||||||||||||||||||||||||||||
Individual Box/Gift Box Color | White | |||||||||||||||||||||||||||||||||||||||||||||||||
Master Carton Size (mm) | 430 x 380 x 275 | |||||||||||||||||||||||||||||||||||||||||||||||||
Gross Weight (kg) | 14.0 | |||||||||||||||||||||||||||||||||||||||||||||||||
Label Width (mm) | 30.0 | |||||||||||||||||||||||||||||||||||||||||||||||||
Label Height (mm) | 20.0 | |||||||||||||||||||||||||||||||||||||||||||||||||
Input Configuration | ||||||||||||||||||||||||||||||||||||||||||||||||||
Description | Molex 26-60-4030 3 Position Header Pin 1: Line, Pin 2: Removed, PIN 3: Neutral Optional Input Wiring Kits are available:
| |||||||||||||||||||||||||||||||||||||||||||||||||
Approvals | ||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||
Popular Products (Stock items) | ||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||
News Releases | ||||||||||||||||||||||||||||||||||||||||||||||||||
|
What is an open frame or internal AC-DC Power supply?
Open frame AC-DC power supplies are also known as AC-DC converters and are a type of internal power supply. The open frame AC to DC power supply is built into the inside of a system and used to convert the AC current into DC voltage.
How Does an AC-DC Adapter Work?
The AC to DC adapter or external power supply consists of a power supply which is enclosed in a housing similar to an AC plug, hence the term plug type, wall plug in, plug-in or plugtop power adapter. The power supply is plugged into the mains socket and the AC Voltage is then converted by the AC to DC adapter power supply into a DC voltage that is fed into the appliance via the output cable connection.