World map English (US)

USB charger power supply AC adapter certified to 60601-1 Medical Grade , 6W

Request Information Download PDF Configure Output Connector
GTM41078-WWVV-X.X-USB Image
Model Image 60601-1 certified Medical USB wall plug in charger power supply with integrated USB receptacle, available in outputs from 5-6VDC. Changeable input plugs available for North America, Europe, United Kingdom, Australia, China, Korea, Argentina, Brazil
Information
Model NumberGTM41078-WWVV-X.X-USB
Description60601-1 certified Medical USB wall plug in charger power supply with integrated USB receptacle, available in outputs from 5-6VDC. Changeable input plugs available for North America, Europe, United Kingdom, Australia, China, Korea, Argentina, Brazil
Agency Documentshttp://www.globtek.info/certs/GTM41078-USB/
CE EC-Declaration for Medicalhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000HThBrEAL
CE EC-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000HThBrEAL
CE EC-Declaration for HouseholdContact GlobTek for more information
UKCA-Declaration for Medicalhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000HThBrEAL
UKCA-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000HThBrEAL
UKCA-Declaration for HouseholdContact GlobTek for more information
Morocco SDoC Declarationhttps://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0Oa000000HThBrEAL
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0Oa000000HThBrEAL
Prop 65 Statementhttps://en.globtek.com/prop-65-statement.pdf
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeWall Plug-in
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor
CategoryICT / ITE / Medical Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)0.3A
Max Output Power Rating (W)6
Output Voltage Range (V)5
EfficiencyV
Ingress ProtectionIndoor Use
Size (mm)41.0 x 71.0 x 31.5
EnclosureUser-added image
Rating Table
Model Number (Final ordering #/Part No to be defined) VoltageAmps (A)Watts (W) RFQ
GTM41078-0505-USB* 515
GTM41078-0605-USB* 51.26
GTM41078-0506-0.8-USB* 5.21.155.98
GTM41078-0506-USB* 60.834.98
GTM41078-0506-USB* 60.834.98
* (Final ordering #/Part No to be defined)
Specifications
A) ELECTRICAL SPECIFICATIONS:
1. Input Voltage: Specified 90-264 Vac, Nameplate rated 100-240 Vac
2. Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60 Hz
3. Output Power (Rated): 6Watts maximum
4. Output Regulation: +/- 5% measured at the output connector measured at the end of a 1 meter USB cordset employing #22 Gauge conductors
5. Line Voltage Regulation: +/- 1% typical measured at the output connector measured at the end of a 1 meter USB cordset employing #22 Gauge conductors
6. Output Ripple (Vp-p): +/-1% or 100 mV whichever is greater measured at the end of a 1 meter USB cordset employing #22 Gauge conductors. Measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with 10 uf electrolytic capacitor connected at the end of the output connector.
7. Turn-On/Turn-Off Overshoot: 5% maximum, 500 us maximum recovery time for 25% step load.
8. Turn-On Delay: 3000 mSEC maximum
9. Hold-Up Time: 8mSec maximum at nominal input and full load.
10. Inrush Current: 30A typical @ 115Vac input ; 60A typical @ 230Vac input
11. Switching Frequency: 66.5 KHz typical

B) PROTECTION
1. Over-Voltage Protection: 110% to 140% of nominal output voltage: Protected unit will recover upon removal of fault
2. Short Circuit: Electronically Protected, unit will recover upon removal of fault
3. Input Protection: Input line fusing

C) SAFETY
1. Dielectric Withstand Voltage: 5656Vdc from primary to secondary
2. Earth Leakage Current: N/A for Class II units, there is no PE Ground pin, so Earth Leakage current is not measured
3. Touch Current: Maximum allowed values: 100uA NC(Normal condition) 500uA SFC(single fault condition)
4. Means of Protection: 2 x MOPP
5. ROHS 2: Complies with EU 2011/65/EU and China SJ/T 11363-2006

D) OTHER:
1. MTBF: 200,000 hours @ 25°C ambient temperature
2. Operating Temperature: 0°C to 40°C ambient temperature
3. Humidity: 0% to 95% relative humidity
4. Storage Temperature: -40°C to 80°C

E) ENCLOSURE
1. Housing: High impact plastic, 94V0 polycarbonate, non-vented
2. Size: 41.0 x 71.0 x 31.5 mm +/-1.0 mm
3. Markings: Label and/or Pad Printed and/or Molded in the case
Derating Curve
Qty (ea.)/Carton210
Individual Box/Gift Box Size (mm)74 x 35 x 42
Individual Box/Gift Box ColorWhite
Master Carton Size (mm)544 x 375 x 151
Gross Weight (kg)14.8
Label Width (mm)29.0
Label Height (mm)18.0
Input Configuration
DescriptionBlade Options for Q Series Wall Plug-in Power SuppliesData Sheet: http://en.globtek.com/interchangeable-blades.php
Insertion Instructions: http://www.globtek.com/pdf/Instructions-Interchangeable-Blades.pdf
Video: Q-Blade Style Instruction Video


User-added image
 

INPUT CONNECTOR: Q-Socket (below are available blades configurations which are "not included" (unless stated above); can be purchased separately, package with power supply or as a separate "Q-KIT" if specified

01. United States / Canada / Japan  NEMA 1-15P/ IEC PLUG Type A [WORKS IN PLUG B] configuration: NA 2 blades, Class II; US/CA/JP P/N: Q-NA(R)
02. Australian AS 3112 configuration: SAA 2 blade/ IEC TYPE I, Class II; AU P/N: Q-SAA(R)
03. UK BS 1363 configuration: UK 3 blade with dummy Ground/ IEC TYPE G, Class II; GB P/N: Q-UK(R)
04. European CEE 7/16 configuration: Europlug 2 pins/ IEC TYPE C [WORKS IN TYPE E&F], Class II; EU P/N: Q-EU(R)
05. Korean KS C8305 configuration: 2 pins/SIMILAR TO IEC TYPE C, Class II; KR P/N: Q-KR(R)
06. Argentina IRAM 2073 configuration: 2 blades/SIMILAR TO IEC TYPE I; AR P/N: Class II Q-AR(R)
07. China GB 2099 configuration: 2 blades/SIMILAR TO TYPE A, Class II; CN P/N:Q-CN(R)
08. India IS 1293 6A/BS546 configuration: 5A, 3 pins with Dummy Ground, Class II/IEC TYPE D; IN P/N: Q-IN(R)
09. IEC60320/C18 Inlet, Class II; P/N: Q-C18(R)
10. Brazilian NBR6147 configuration: 2 pins, Class II;SIMILAR TO IEC TYPE C BR P/N: Q-BR(R)
11. South Africa SABS164-1, 3 round prongs, Class II + dummy ground, IEC TYPE M P/N: Q-SANS164-1-16A(R)
12. South Africa SABS164-4, 3 round prongs with a notched prong @ 0º, Class II + dummy ground, IEC TYPE M Red, P/N:
Q-SANS164-4L-16A(R)
13. South Africa SABS164-4, 3 round prongs with a notched prong @ -
53º, Class II + dummy ground, Blue, IEC TYPE M, P/N:
Q-SANS164-4C-16A(R)
14. South Africa SABS164-4, 3 round prongs with a notched prong @ +53º, Class II + dummy ground, Black,IEC TYPE M P/N:
Q-SANS164-4R-16A(R)

Kits

01. Q-KIT: 1,2,3,4 above
02. Q-KIT-INTL: 2,3,4 above
03. Q-KIT-6: 1,2,3,4,5,6 above
04. Q-KIT-7: 1,2,3,4,5,6,7 above
05. Q-KIT-8: 1,2,3,4,5,6,7,8 above

Output Configuration
Common output connector options:
Click to add to your request.
L Type (Coaxial 5.5x2.5mm plug)
C Type (Coaxial 5.5x2.1mm plug)
K Type (Coaxial 3.5x1.3mm plug)
LL Type (5.5x2.5mm Locking 760k type)
CL Type (5.5x2.1mm Locking S761k type)
Magnetic Connector
L Type (Coaxial 5.5x2.5mm plug) C Type (Coaxial 5.5x2.1mm plug) K Type (Coaxial 3.5x1.3mm plug) LL Type (5.5x2.5mm Locking 760k type) CL Type (5.5x2.1mm Locking S761k type) Magnetic Connector
YL3 Type (KPPX-3P)
YL4 Type (KPPX-4P)
EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)
MSB Type (Micro USB)
Custom design
YL3 Type (KPPX-3P) YL4 Type (KPPX-4P) EJ1/2/3/4/5 (EIAJ RC-5320A type connectors) MSB Type (Micro USB) Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals
LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
 User-added imageTaiwan BSMI 5V design only; http://www.bsmi.gov.tw/wSite/ct?xItem=4072&ctNode=816&mp=2
No Logo ApplicableCB report IEC60601-1 2005 A1+C1+C2 2016-2-4 and or EN 60601-1:2006 3.1rd Edition 2xMOPP (for GTM41078-WW05 only)
No Logo CB Report IEC60950-1:2005 (2nd Edition), Am 1: 2009 and EN 60950-1:2006 + Am 1:2010 + Am 11:2009 + Am 12:2011 (for GTM41078-WW05 only)
User-added imageCCC to GB4943.1-2011; GB/T9254-2008 GB17625.1-2012, Tropical <2000
User-added image  CE Mark: tested to comply with EN 60601-1-2:2015 Medical electrical equipment Part 1-2: - Mark is on the label or Molded in the case
User-added imagecETLus ANSI_AAMI ES60601-1_2005 (for GTM41078-WW05 only)
User-added imageConforms to ANSI/UL Std. 60950-1 2nd Edition Cert. to CAN/CSA Std.C22.2 NO.60950-1 2nd Edition (for GTM41078-WW05 only)
User-added image
 
cETLus-Cert-4007497 ANSI/AAMI ES60601-1:2005 with AMD C1: 2009, AMD C2: 2010 and CAN/CSA-C22.2 No. 60601-1 2008 with COR 2:2011(for GTM41078-WW05 only)
User-added imagecETLus-Cert-60950-1 4007497 Listed (for GTM41078-WW05 only)
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
User-added image
User-added image  Certification # TC RU AR46.B.69004 Custom Union of Russia, Belarus and Kazakhstan
No LogoEC-Conformity Declaration: http://www.globtek.com/html/iso_certificates/EC-DECLARATION.pdf, REACH 144 SVHC: http://www.globtek.com/html/iso_certificates/Reach144.pdf
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
IP20Ingress Protection: IP20 to IEC60529:2001 Protected against solids objects over 12mm and No Protection
User-added imageIRAM certificate DC-E-G71-001.10 to IEC 60950-1:2005 + A1:2009
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50471624, to J62368-1(H30) , J55032(H29),J3000(H25,[15V or less]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageHU10499-15021A GTM41078-0605-USB (5V only)
No LogoKuwait GTM41078-0605-USB IEC 60950-1:2005(2 ND EDITION) + Am 1:2009 + Am 2:2013
 User-added image

Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
LPSLimited Power Source 60950
User-added image
 
NOM (ETL) to NOM-001-SCFI-1993 (5 Volts only)
User-added imageRCM certificate to SAA152289EA ; Australia and New Zealand Regulatory Compliance, Mark (http://rcm.standards.org.au/rcmfaq/rcmfaq.htm
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added imageSemko S-Mark-Cert-EN60601-1 3rd Edition (http://www.intertek.com/marks/s/) (for GTM41078-WW05 only)

User-added image
Saudi Arabia approval GTM41078-0605-USB IEC 60950-2005
User-added imageSerbia Approval - Conformity mark must be at least 5 mm high.
User-added imageSGS (Brazil) to IEC 60950-1_2005(ed.2) + A1 2009 +A2 2013 EN60950-1:2006 + A11: 2009 + A1: 2010 + A12: 2011 + A2: 2013
 No Logo12
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample Request Distributor Stock (Click to order)
6542445.01.2Type "A" USB “JACK”, integral to power supply enclosure
2645415.01.2Type "A" USB “JACK”, integral to power supply enclosure
2633935.01.2Type "A" USB “JACK”, integral to power supply enclosure
2178175.01.2Type "A" USB “JACK”, integral to power supply enclosure
2177505.01.2Type "A" USB “JACK”, integral to power supply enclosure
2374645.01.2Type "A" USB “JACK”, integral to power supply enclosure
2276015.01.2Type "A" USB “JACK”, integral to power supply enclosure
2264915.01.2Type "A" USB “JACK”, integral to power supply enclosure
2262905.01.2Type "A" USB “JACK”, integral to power supply enclosure
1997575.01.2Type "A" USB “JACK”, integral to power supply enclosure
2113485.01.2Type "A" USB “JACK”, integral to power supply enclosure
1879245.01.2Type "A" USB “JACK”, integral to power supply enclosure
1871185.01.2Type "A" USB “JACK”, integral to power supply enclosure
1864875.01.2Type "A" USB “JACK”, integral to power supply enclosure
1835265.01.2Type "A" USB “JACK”, integral to power supply enclosure
8962605.01.2Type "A" USB “JACK”, integral to power supply enclosure
3390255.01.2Type "A" USB “JACK”, integral to power supply enclosure
1919705.01.2Type "A" USB “JACK”, integral to power supply enclosure
1617325.01.0Type "A" USB “JACK”, integral to power supply enclosure
WR9QA1200USBNMEDRVB5.01.2Type "A" USB “JACK”, integral to power supply enclosure 191
1748145.01.2Type "A" USB “JACK”, integral to power supply enclosure
1754805.01.2Type "A" USB “JACK”, integral to power supply enclosure
1775295.01.2Type "A" USB “JACK”, integral to power supply enclosure
1932255.01.2Type "A" USB “JACK”, integral to power supply enclosure
1807525.01.0Type "A" USB “JACK”, integral to power supply enclosure
1932275.01.2Type "A" USB “JACK”, integral to power supply enclosure
1959755.01.2Type "A" USB “JACK”, integral to power supply enclosure
1972475.01.2Type "A" USB “JACK”, integral to power supply enclosure
1983595.01.2Type "A" USB “JACK”, integral to power supply enclosure
1983665.01.2Female Barrel 3.5*1.35*9.5mm, Locking with Spring-loaded or Equal
1803735.01.2Type "A" USB “JACK”, integral to power supply enclosure
2177515.21.2Type "A" USB “JACK”, integral to power supply enclosure
1828515.20.96Type "A" USB “JACK”, integral to power supply enclosure
News Releases
TitleWeb Link
USB AC Adapter/Power Supply Certified to ANSI/AAMI ES60601-1 for the United States and Canada and EN/IEC 60601-1, 3rd edition for Europe, Asia, and Africa and is rated up to 6W output with 5-6V output options., Model Series WR9QA1000USBNMEDRVB GTM41078-06http://en.globtek.com/news.php/usb-ac-adapter-power-supply-certified-to-ansiaami-es60601-1-for-the-united-states-and-canada-and-eniec-60601-1-3rd-edition-for-europe-asia-and-africa-and-is-rated-up-to-6w-output-with-5-6v-output-options-model-series-wr9qa10
USB Medical (60601-1) Power Supply AC Adapter Certified to IEC 60601-1: 2005 + CORR. 1 (2006) + CORR. 2 (2007) and EN 60601-1:2006 + A11:2011 via CB Report a is rated up to 5W output with 5-36V output options. Model Series GTM41078-USBhttp://en.globtek.com/news.php/usb-medical-60601-1-power-supply-ac-adapter-certified-to-iec-60601-1-2005-corr-1-2006-corr-2-2007-and-en-60601-12006-a112011-via-cb-report-a-is-rated-up-to-5w-output-with-5-36v-output-options-model-series-gtm41078-usb#.Uk8AT
USB Medical (60601-1) External Freestanding Power Supply AC Adapter Certified to ANSI/AAMI ES60601-1 for the United States and Canada is rated up to 6W output with 3.3-48V output options., Model Series GTM41078-USBhttp://en.globtek.com/news.php/usb-medical-60601-1-external-freestanding-power-supply-ac-adapter-certified-to-ansiaami-es60601-1-for-the-united-states-and-canada-is-rated-up-to-6w-output-with-33-48v-output-options-model-series-gtm41078-usb#.Uk8RLxA6DaM
Korean Certificate GTM41078-0605-USB K60950-1(2.0)(2011-12)
What is an IEC 60601-1 medical grade rated power supply AC adapter?

An IEC 60601-1-2 medical grade rated power supply AC adapter converts input line voltage from the wall to a lower voltage, typically DC, which is used to operate and end use piece of medical equipment. IEC 60601-1-2 medical grade power supply AC adapters are typically housed in a plastic enclosure and are available with both 2 and 3 prong input options. power supplies are also available as open frame for use inside of medical equipment. These AC to DC converters are designed in accordance with international medical standards and provide for compliance with certain aspects of them which differs from generic information and communication technology equipment power supplies.

Why is my medical grade IEC 60601-1 power supply certified to IEC 60601-1 3rd Edition while the latest standard is IEC 60601-1 4th Edition?
IEC 60601-1 has different sections in specifications for safety and EMI/EMC. The latest revision of the safety portion of  IEC 60601-1 is 3rd Edition while for EMI/EMC the latest revision is 60601-1-2, 4th Ed. 

What is the effective date of 60601-1-2, 4th Ed?
60601-1-2, 4th Ed. was effective on December 31, 2018.

What's the difference between an IEC 60950-1 and IEC 60601-1 medical grade rated power supply?

IEC 60950-1 and IEC 60601-1-2 power supplies are both AC to DC converters and may be either internal or external but are designed to different specifications to match the end system specifications. While the basic performance behaviors are similar such as input and output voltages and mechanical configurations, there are many differences as well. Some of the key differences are that medical IEC 60601 medical grade AC to DC adapters are able to withstand a higher dielectric withstand voltage and must have lower leakage current.  There are many other differences and also considerations to consider depending on the end use application.  

What MOOP and MOPP?
Medical devices must incorporate one or more Means of Protection (MOPs) to isolate patients and operators from the risks of electrocution. A Means of Protection (MOPs)  can be safety insulation, a protective earth, a defined creepage distance, or an air gap or other protective impedance. These can be used in various combinations. IEC 60601-1 3rd edition differentiates between the risk to patients and the risk to operators. A MOP can therefore be classified as Means of Patient Protection (MOPP) or a Means of Operator Protection (MOOP). The main difference between one MOOP and one MOPP is primarily one of permissible creepage distance. Both requirements are satisfied using Basic insulation. To achieve 2 x MOPP qualification the isolation test is particularly demanding at 4000 Vac and the creepage distance of 8mm is twice that required for one MOPP. 

What is a BF and CF rated an IEC 60601-1-2 medical grade rated power supply AC adapter and what is the difference?

Medical grade power supplies and AC to DC adapters are categorized into one of three applied parts types: body type (B), body floating type (BF), and cardiac floating type (CF). These applied parts require specific attributes such as isolation voltage, creepage and leakage current. Floating refers to an ungrounded power supply, Class II, that is not referenced to another output and is fully isolated. Type B refers to devices that operate within the patient's vicinity, as described in IEC 60601-1 as six feet around a patient's chair or bed and do not touch the patient electronically and are grounded. These devices include operating room lighting, hospital carts and beds, automated dispensers of medication and supplies, and diagnostic equipment like x-ray machines. Type BF devices deliver electrical energy signals to or from the patient such as electrosurgical devices, endoscopes, and electrical vital sign monitors like thermometers. Type CF devices are similar to BF, except they supply power to devices connected to the heart, such as a defibrillator, external pacemaker or intracardiac ECG electrodes and Type CF requires a higher degree of protection against electrical shock than BF types.  
 

What is a Plug-in AC-DC Adapter?

Plug in AC-DC adapters are also known as AC Adaptors or AC-DC converters and are a type of external power supply. Some electrical appliances require power but lack the internal components to derive the required voltage and power from mains power. This is where an AC adapter is used to convert the AC current into DC voltage

How Does an AC-DC Adapter Work?

The AC to DC adapter or external power supply consists of a power supply which is enclosed in a housing similar to an AC plug, hence the term plug type, wall plug in, plug-in or plugtop power adapter. The power supply is plugged into the mains socket and the AC Voltage is then converted by the AC to DC adapter power supply into a DC voltage that is fed into the appliance via the output cable connection.

Request Info
Call
Email
💬
Text
💁
Chat
?
Request a Quote
Can we help you?
Can we help you?