GTM86100-10VV-W2U-USB Wall Plug-in ICT / ITE / Medical Power Supply Datasheet
Information | |||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Model Number | GTM86100-10VV-W2U-USB | ||||||||||||||||||||||||||||||
Description | GTM86100-10VV-W2U-USB, ICT / ITE / Medical Power Supply, Wall Plug-in, AC/DC Switching Adapter with USB Power Supply AC Adaptor, , Input Rating: 100-240V ̴ , 50/60Hz, UK BS 1363, 2 Blade w/Dummy Ground Class II, Output Rating: 10 Watts, Power rating with convection cooling (W) , 5-5.2V in 0.1V increments, Approvals: CB 60335; WEEE; UKCA; China RoHS; Double Insulation; Level VI; RoHS; VCCI; EAC; CB 62368; CE; | ||||||||||||||||||||||||||||||
Agency Documents | http://www.globtek.info/certs/GTM86100/ | ||||||||||||||||||||||||||||||
CE EC-Declaration for Medical | Contact GlobTek for more information | ||||||||||||||||||||||||||||||
CE EC-Declaration for Industrial/Commercial/ITE | https://globtek.secure.force.com/models/ec_declaration?id=a0O0c00000PGJ17EAH | ||||||||||||||||||||||||||||||
CE EC-Declaration for Household | Contact GlobTek for more information | ||||||||||||||||||||||||||||||
UKCA-Declaration for Medical | Contact GlobTek for more information | ||||||||||||||||||||||||||||||
UKCA-Declaration for Industrial/Commercial/ITE | https://globtek.secure.force.com/models/ukca_declaration?id=a0O0c00000PGJ17EAH | ||||||||||||||||||||||||||||||
UKCA-Declaration for Household | Contact GlobTek for more information | ||||||||||||||||||||||||||||||
Morocco SDoC Declaration | https://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0O0c00000PGJ17EAH | ||||||||||||||||||||||||||||||
RoHS/RoHS3 Declaration | https://www.globtek.com/pdf/rohs_cert/a0O0c00000PGJ17EAH | ||||||||||||||||||||||||||||||
Prop 65 Statement | https://en.globtek.com/prop-65-statement.pdf | ||||||||||||||||||||||||||||||
REACH Declaration | https://www.globtek.com/pdf/iso_certificates/REACH.pdf | ||||||||||||||||||||||||||||||
Conflict Minerals Declaration | https://www.globtek.com/pdf/conflict-minerals.pdf | ||||||||||||||||||||||||||||||
Model Parameters | |||||||||||||||||||||||||||||||
Type | Wall Plug-in | ||||||||||||||||||||||||||||||
Technology | AC/DC Switching Adapter with USB Power Supply AC Adaptor | ||||||||||||||||||||||||||||||
Category | ICT / ITE / Medical Power Supply | ||||||||||||||||||||||||||||||
Input Voltage Range (V) | 100-240V ̴ , 50/60Hz | ||||||||||||||||||||||||||||||
Max Input Current (A) | 0.3A | ||||||||||||||||||||||||||||||
Max Output Power Rating (W) | 10 | ||||||||||||||||||||||||||||||
Output Voltage Range (V) | 5-5.2 | ||||||||||||||||||||||||||||||
Efficiency | USA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782 | ||||||||||||||||||||||||||||||
Ingress Protection | |||||||||||||||||||||||||||||||
Size (mm) | 60.9*48.4*32.2 | ||||||||||||||||||||||||||||||
Enclosure | |||||||||||||||||||||||||||||||
3D File Download | https://www.globtek.com/dl/GTM86100-10VV-W2U-USB.STP | ||||||||||||||||||||||||||||||
Rating Table | |||||||||||||||||||||||||||||||
* (Final ordering #/Part No to be defined)
| |||||||||||||||||||||||||||||||
Specifications | |||||||||||||||||||||||||||||||
01. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac 02. Input Frequency: Specified 47-63 Hz, Nameplate rated 50/60Hz 03. Output Regulation: +/- 5% measured at the end of a 1 meter USB cordset employing #20 Gauge conductors 04. Line Voltage Regulation: +/- 1% typical measured at the end of a 1 meter USB cordset employing #20 Gauge conductors 05. Output Ripple (Vp-p): 100 mVpp max, measured at the end of a 1 meter USB cordset employing #20 Gauge conductors. Measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with a low impedance 47 uf electrolytic capacitor connected at the end of the output connector. 06. Hold-up Time: 5 mS minimum 07. Inrush Current: 30A maximum @ 230Vac input 08. Energy Efficiency: Complies to Efficiency Level VI and ErP European Commission's Ecodesign Directive (2005/32/EC) / CoC Tier 2 Compliant B) PROTECTION 01. Over-current protection: 4A maximum with auto-recovery function 02. Over-voltage protection: 10VDC maximum with zener clamp 03. Short-circuit protection: The adapter shall not be damaged by short the DC output to Ground. C) SAFETY 01. Dielectric Withstand Voltage: Primary To Secondary: 4000VAC or 5656VDC for 3 seconds 02. Leakage Current: 50uA maximum, at nominal 240Vac input voltage 03. ESD Immunity per EN61000-4-2, ±8 kV contact, ±15 kV air, Perf Criteria A Standard. D) EMC 01. Emissions, per EN 55032, EN 61000-6-3, EN 61000-6-4 Conducted Emissions: Class B, FCC Part 15, Class B Radiated Emissions: Class B, FCC Part 15, Class B 02. Line Frequency Harmonics EN61000-3-2, Class A 03. Voltage Fluctuations/Flicker EN61000-3-3 04. Immunity, per EN 55024, EN 61000-6-1, EN 61000-6-2 Static Discharge Immunity EN61000-4-2, 8kV Contact Discharge, 15kV air discharge Radiated RF Immunity EN61000-4-3, 3V/m 80-2700MHz, 80% 1KHz AM. EFT/Burst Immunity EN61000-4-4, 2kV/100kHz. Line Surge Immunity EN61000-4-5, 1kV differential, 2kV common-mode Conducted RF Immunity EN61000-4-6, 3Vrms, 80% 1KHz AM Power Frequency Magnetic Field Immunity EN61000-4-8, NA Voltage Dip Immunity EN61000-4-11, Criteria E) OTHER: 01. MTBF: 300,000 Hours @ 25°C ambient temperature 02. Operating Temperature: 0°C to 50°C ambient temperature 03. Operating Humidity: 20 ~ 85 % RH. non-condensing 05. Storage Temperature: -20°C to 60°C 06. Storage Humidity:5 ~ 95 % RH. non-condensing 07. Cooling: Natural convection cooling 08. RoHS 2: Complies with EU 2011/65/EU China SJ/T 11364-2014 F) ENCLOSURE 01. Housing: High impact plastic, 94V0 polycarbonate, non-vented 02. Markings: Label and/or Pad Printed and/or Molded in the case F) OPTIONS: 01. NEMA 1-15P or European Schuko 7-16 AC Plug Configuration 02. Increased DC Output Voltage (up to 5.4V) to allow for long output cables 03. Special International Safety Approvals 04. Housing Color, special markings | |||||||||||||||||||||||||||||||
Derating Curve | |||||||||||||||||||||||||||||||
Qty (ea.)/Carton | 300 | ||||||||||||||||||||||||||||||
Individual Box/Gift Box Size (mm) | 90*54*50 | ||||||||||||||||||||||||||||||
Individual Box/Gift Box Color | White | ||||||||||||||||||||||||||||||
Master Carton Size (mm) | 470 x 345 x 288 | ||||||||||||||||||||||||||||||
Gross Weight (kg) | 12 | ||||||||||||||||||||||||||||||
Label Width (mm) | 37.0 | ||||||||||||||||||||||||||||||
Label Height (mm) | 19.0 | ||||||||||||||||||||||||||||||
Input Configuration | |||||||||||||||||||||||||||||||
Description | UK BS 1363, 2 Blade w/Dummy Ground Class II The line and neutral pins have a rectangular cross section 6.35 mm by 4.0 mm, 17.7 mm long and with centres 22.2 mm apart. The protective-earth pin is a rectangular cross section 8.0 mm by 4.0 mm, 22.3 mm long and with a centre line 22.2 mm from the line/neutral pin centre line. The dimensions were originally specified in decimal inches with asymmetric tolerances and redefined as minimum and maximum metric dimensions in BS 1363:1984. Dimensions are chosen to provide safe clearance to live parts. The distance from any part of the line and neutral pins to the periphery of the plug base must be not less than 9.5 mm. This ensures that nothing can be inserted alongside a pin when the plug is in use, and helps keep fingers away from the pins. The minimum insertion distance from the face of the socket-outlet to the first point of contact with a live part is 9.6 mm. The "Dummy" longer earth pin ensures that the earth path is connected before the live pins, and remains connected after the live pins are removed. The earth pin is too large to be inserted into the line or neutral sockets by mistake. | ||||||||||||||||||||||||||||||
Output Configuration | |||||||||||||||||||||||||||||||
Common output connector options: Click to add to your request.
For a comprehensive list of options, click here Contact GlobTek for your specific requirements or custom solutions. | |||||||||||||||||||||||||||||||
Approvals | |||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||
Popular Products (Stock items) | |||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||
News Releases | |||||||||||||||||||||||||||||||
|
What is a USB Plug-in AC-DC Adapter?
Plug in USB AC-DC adapters are also known as USB AC Adaptors or USB AC-DC converters and are a type of external power supply. Some electrical appliances require power but lack the internal components to derive the required voltage and power from mains power. This is where an AC adapter is used to convert the AC current into DC voltage. These USB power supplies provide a USB type A or a USB Type-C receptacle in the body of the housing and are ready to be used with separate USB cables.
What is a IEC 62368-1:2018 power supply?
IEC 62368-1:2018 is applicable to the safety of electrical and electronic equipment within the field of audio, video, information and communication technology, and business and office machines with a rated voltage not exceeding 600 V. This is a product safety standard that classifies energy sources, prescribes safeguards against those energy sources, and provides guidance on the application of, and requirements for, those safeguards. The prescribed safeguards are intended to reduce the likelihood of pain, injury and, in the case of fire, property damage. An IEC 62368-1 rated AC to DC converter or power supply is a power supply that has been tested to and certified to comply with the said standard.
Did IEC 62368-1 power supplies replace IEC60950-1 power supplies?
On December 20, 2020 the safety standards that historically have applied to information technology equipment and audio video equipment, IEC 60065 and IEC 60950-1,transition to IEC 62368-1. In North America ETL and UL 60950-1 certifications will continue to stay valid and may continue to be used until further notice.
What is the difference between an IEC 62368-1 and a IEC 60950-1 power supply?
While the structure and contents of the standards are very different in general most products that previously complied with IEC 60950-1 comply with the latest standard IEC 62368-1 with little or no modification.
Will my IEC60950-1 power supply remain available?
GlobTek will continue to manufacture and supply IEC 60950-1 power supplies indefinitely until further notice.
What is Level VI Efficiency?
The numerals I to VI are an International Efficiency Marking Protocol which allows manufacturers to designate the efficiency performance of a product. This performance is based on the measurement of the operating energy efficiency and no-load power consumption of external power supplies or AC DC adapters tested at different load levels. The no-load power consumption refers to the amount of power that an external power supply draws even when the application is turned off or disconnected.
Is Level VI Efficiency required?
Level VI efficiency is mandated in certain countries and regions for certain products or certain applications.
What is the Eco-design Directive 2009/125/EC?
The Eco-design directive put into law in Europe the latest requirements for energy efficiency and conservation for AC DC adapters and external power supplies.
What is a Plug-in AC-DC Adapter?
Plug in AC-DC adapters are also known as AC Adaptors or AC-DC converters and are a type of external power supply. Some electrical appliances require power but lack the internal components to derive the required voltage and power from mains power. This is where an AC adapter is used to convert the AC current into DC voltage