GT-41060-WWVV-X.X-FW Open Frame/Internal ICT/ITE Power Supply Datasheet

GT-41060-WWVV-X.X-FW Image
Model ImageGT-41060-WWVV-X.X-FW, ICT/ITE Power Supply,  60601-1-4th Ed. , Open Frame/Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, Molex 09-65-2038 3 Position Header Pin 1: Neutral, Pin 2: Removed, Pin 3: Line, Output Rating: 25 Watts, Power rating with convection cooling (W) , 3.0-30V in 0.1V increments, Approvals: Belarus (12V only); UKCA; RoHS; CE; Ukraine; cRUus  (up to 30V); China RoHS; Double Insulation; Level IV 1meter 115; NEMKO; VCCI; WEEE; FCC; LPS 60950; EAC; SIQ (up to 30V only); GT-41060-WWVV-X.X-FW, ICT/ITE Power Supply,  60601-1-4th Ed. , Open Frame/Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, Molex 09-65-2038 3 Position Header Pin 1: Neutral, Pin 2: Removed, Pin 3: Line, Output Rating: 25 Watts, Power rating with convection cooling (W) , 3.0-30V in 0.1V increments, Approvals: Belarus (12V only); UKCA; RoHS; CE; Ukraine; cRUus  (up to 30V); China RoHS; Double Insulation; Level IV 1meter 115; NEMKO; VCCI; WEEE; FCC; LPS 60950; EAC; SIQ (up to 30V only);
Information
Model NumberGT-41060-WWVV-X.X-FW
DescriptionGT-41060-WWVV-X.X-FW, ICT/ITE Power Supply, 60601-1-4th Ed. , Open Frame/Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, Molex 09-65-2038 3 Position Header Pin 1: Neutral, Pin 2: Removed, Pin 3: Line, Output Rating: 25 Watts, Power rating with convection cooling (W) , 3.0-30V in 0.1V increments, Approvals: Belarus (12V only); UKCA; RoHS; CE; Ukraine; cRUus (up to 30V); China RoHS; Double Insulation; Level IV 1meter 115; NEMKO; VCCI; WEEE; FCC; LPS 60950; EAC; SIQ (up to 30V only); GT-41060-WWVV-X.X-FW, ICT/ITE Power Supply, 60601-1-4th Ed. , Open Frame/Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, Molex 09-65-2038 3 Position Header Pin 1: Neutral, Pin 2: Removed, Pin 3: Line, Output Rating: 25 Watts, Power rating with convection cooling (W) , 3.0-30V in 0.1V increments, Approvals: Belarus (12V only); UKCA; RoHS; CE; Ukraine; cRUus (up to 30V); China RoHS; Double Insulation; Level IV 1meter 115; NEMKO; VCCI; WEEE; FCC; LPS 60950; EAC; SIQ (up to 30V only);
Agency Documentshttp://www.globtek.info/certs/GT-41060/
CE EC-Declaration for Medicalhttps://globtek.secure.force.com/models/ec_declaration?id=a0O30000007P7ZJEA0
CE EC-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ec_declaration?id=a0O30000007P7ZJEA0
CE EC-Declaration for HouseholdContact GlobTek for more information
UKCA-Declaration for Medicalhttps://globtek.secure.force.com/models/ukca_declaration?id=a0O30000007P7ZJEA0
UKCA-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ukca_declaration?id=a0O30000007P7ZJEA0
UKCA-Declaration for HouseholdContact GlobTek for more information
Morocco SDoC Declarationhttps://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0O30000007P7ZJEA0
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0O30000007P7ZJEA0
Prop 65 Statementhttps://en.globtek.com/prop-65-statement.pdf
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeOpen Frame/Internal
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor
CategoryICT/ITE Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)0.6 A Max
Max Output Power Rating (W)25
Output Voltage Range (V)3.0-30
Efficiency
Ingress Protection
Size (mm)98*50*28
Enclosure
Enclosure size: 98*50*28 ± 0.5 mm

 User-added image
Input Connector: Molex 09-65-2038                                         Output Connector: Molex 22-27-2061
                                                                                                  or equivalent









 

 


                                  
 
Rating Table
Model Number (Final ordering #/Part No to be defined)VoltageAmps (A)Watts (W)RFQ
GT-41060-1003-FW*32.67.8
GT-41060-1505-FW*5315
GT-41060-1706-FW*62.816.8
GT-41060-1809-FW*9218
GT-41060-2512-FW*122.0824.96
GT-41060-2515-FW*151.6624.9
GT-41060-2518-FW*181.3824.84
GT-41060-2520-FW*201.2525
GT-41060-2524-FW*241.0424.96
GT-41060-2530-FW*300.8324.9
GT-41060-2548-FW*480.5224.96
* (Final ordering #/Part No to be defined)
Specifications
NOTES:
1. Each output current may vary within it's designated range, as long as output power is not exceeded.
2. Single output may vary from 3VDC-30VDC in 0.1V increments.
3. Voltage differentiator X.X is optional, used only for specifying output voltage deviation from listed ratings.
Subtract X.X from rated voltage.

A) ELECTRICAL SPECIFICATIONS:
1. INPUT VOLTAGE: 100-240 VAC
2. INPUT CURRENT: < 0.6 A RMS MAX
3. INPUT FREQUENCY: 47 - 63 HZ
4. OUTPUT POWER: 25WATTS, MAXIMUM
5. OUTPUT RIPPLE VOLTAGE (PEAK TO PEAK): +/-1% OR 50 mV WHICHEVER IS GREATER AT NOMINAL
OUTPUT VOLTAGE.MEASURED AT 20 MHz BANDWIDTH WITH 0.1μf CERAMIC CAPACITOR IN PARALLEL WITH
10 μf ELECTROLYTIC CAPACITOR CONNECTED AT THE END OF THE OUTPUT CONNECTOR.
6. OUTPUT REGULATION: +/- 3 % OF NOMINAL OUTPUT VOLTAGE,
7. MEASURED AT O/P CONNECTOR AT NOMINAL LINE
8. LINE REGULATION: +/- 1 % MAX AT FULL LOAD
9. TURN ON/ TURN OFF OVERSHOOT: 5% MAX 500uS MAX RECOVERY TIME FOR 25% TO 50% STEP LOAD
10. TURN-ON DELAY: 3000 mSEC MAX AT FULL LOAD, 115 VAC
11. HOLD-UP TIME: 10 mSEC MIN AT NOMINAL INPUT AND FULL LOAD
12. INRUSH CURRENT: 30 A MAX AT COLD START 120 VAC, 60A MAX COLD START 230VAC
13. SWITCHING FREQUENCY: 66.5 KHz TYPICAL
14. OVER-VOLTAGE PROTECTION: PROTECTED, HICCUP WITH AUTO RECOVERY
15. OVER-LOAD: PROTECTED, HICCUP WITH AUTO RECOVERY
16. SHORT CIRCUIT: PROTECTED, HICCUP WITH AUTO RECOVERY
17. EFFICIENCY: 80% TYPICAL AT NOMINAL LINE
18. INDICATOR: BLUE LED FOR OUTPUT PRESENT
19. NO LOAD POWER CONSUMPTION: MEETS CEC/EISA LEVEL IV, 115 VAC

B) PROTECTION
1. OTHER PROTECTION: INPUT LINE AND NEUTRAL FUSING

C) SAFETY
1. DIELECTRIC WITHSTAND VOLTAGE: 4242 VDC PRIMARY-SECONDARY
2. LEAKAGE CURRENT: < 0.3 mA AT 240 VAC

D) OTHER:
1. MTBF: 200,000 HOURS AT 25°C AMBIENT TEMPERATURE
2. OPERATING TEMPERATURE: 0°C TO 40°C
3. STORAGE TEMPERATURE: -40°C TO 80°C
4. HUMIDITY: 0% TO 90% RELATIVE HUMIDITY
5. ROHS 2: COMPLIES WITH EU 2011/65/Eu AND CHINA SJ/T 11363-2006
Derating CurveUser-added image
Qty (ea.)/Carton100
Individual Box/Gift Box Size (mm)Egg Crate
Individual Box/Gift Box ColorNone
Master Carton Size (mm)469 x 395 x 250
Gross Weight (kg)15.6
Label Width (mm)18.0
Label Height (mm)15.0
Input Configuration
DescriptionMolex 09-65-2038 3 Position Header Pin 1: Neutral, Pin 2: Removed, Pin 3: LineDocument: http://www.molex.com/pdm_docs/sd/009652038_sd.pdf
Catalog Page: http://www.molex.com/molex/products/datasheet.jsp?part=active/0009652038_PCB_HEADERS.xml

User-added image
 

Mates With Part(s):

5195 SPOX™ Crimp Housing, 5239 KK® Crimp Housing
Optional Input Wiring Kits are available:

PN/Ordering No   Length  End A   End B
XHP410070M7MLX3(R)70JST XHP-4  Molex 09-93-0300
C810070M6MLX3(R)60IEC60320 C8  Molex 09-93-0300
C1410070M6MLX3(R)60IEC60320 C14  Molex 09-93-0300
Approvals

Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.

Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.

LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)

User-added image
 
Belarus certificate J\l By/I 12 03. 1 I . 020 05936 only for GTM41060-2512 and GT-41060-2512
User-added image  CE Mark: tested to comply with EN55022:2006/A1:2007 Class B, EN610003-2, EN610003-3 including EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6N EN61000-4-11; EMI: Complies with EN55011 CLASS B and FCC Part 15B - On label or Molded in case
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
User-added imagecRUus Registered E170507 CSA C22.2 No. 60950-1 2nd Ed. (up to 30V)
User-added image
User-added image  Certification # TC RU AR46.B.75423 Custom Union of Russia, Belarus and Kazakhstan
UL FCC MarkFCC Mark
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
 User-added image Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe) exception 5.1~6.9V require 1000 mm output cable
LPSLimited Power Source 60950
Nemko
NEMKO
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added image
 
IEC 60601-1:2005 (Third Edition) + CORR. 1:2006 + CORR. 2:2007 + A1:2012 (or IEC 60601-1: 2012 reprint) up to 30V only
User-added image
 
UKCA Certification
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample Request
12904412.02.08
10876615.01.67
149592
1513809.02.0
16351630.0
15110112.01.0
20119512.02.1
1954477.5
What is an IEC 60601-1 medical grade rated power supply AC adapter?

An IEC 60601-1-2 medical grade rated power supply AC adapter converts input line voltage from the wall to a lower voltage, typically DC, which is used to operate and end use piece of medical equipment. IEC 60601-1-2 medical grade power supply AC adapters are typically housed in a plastic enclosure and are available with both 2 and 3 prong input options. power supplies are also available as open frame for use inside of medical equipment. These AC to DC converters are designed in accordance with international medical standards and provide for compliance with certain aspects of them which differs from generic information and communication technology equipment power supplies.

Why is my medical grade IEC 60601-1 power supply certified to IEC 60601-1 3rd Edition while the latest standard is IEC 60601-1 4th Edition?
IEC 60601-1 has different sections in specifications for safety and EMI/EMC. The latest revision of the safety portion of  IEC 60601-1 is 3rd Edition while for EMI/EMC the latest revision is 60601-1-2, 4th Ed. 

What is the effective date of 60601-1-2, 4th Ed?
60601-1-2, 4th Ed. was effective on December 31, 2018.

What's the difference between an IEC 60950-1 and IEC 60601-1 medical grade rated power supply?

IEC 60950-1 and IEC 60601-1-2 power supplies are both AC to DC converters and may be either internal or external but are designed to different specifications to match the end system specifications. While the basic performance behaviors are similar such as input and output voltages and mechanical configurations, there are many differences as well. Some of the key differences are that medical IEC 60601 medical grade AC to DC adapters are able to withstand a higher dielectric withstand voltage and must have lower leakage current.  There are many other differences and also considerations to consider depending on the end use application.  

What MOOP and MOPP?
Medical devices must incorporate one or more Means of Protection (MOPs) to isolate patients and operators from the risks of electrocution. A Means of Protection (MOPs)  can be safety insulation, a protective earth, a defined creepage distance, or an air gap or other protective impedance. These can be used in various combinations. IEC 60601-1 3rd edition differentiates between the risk to patients and the risk to operators. A MOP can therefore be classified as Means of Patient Protection (MOPP) or a Means of Operator Protection (MOOP). The main difference between one MOOP and one MOPP is primarily one of permissible creepage distance. Both requirements are satisfied using Basic insulation. To achieve 2 x MOPP qualification the isolation test is particularly demanding at 4000 Vac and the creepage distance of 8mm is twice that required for one MOPP. 

What is a BF and CF rated an IEC 60601-1-2 medical grade rated power supply AC adapter and what is the difference?

Medical grade power supplies and AC to DC adapters are categorized into one of three applied parts types: body type (B), body floating type (BF), and cardiac floating type (CF). These applied parts require specific attributes such as isolation voltage, creepage and leakage current. Floating refers to an ungrounded power supply, Class II, that is not referenced to another output and is fully isolated. Type B refers to devices that operate within the patient's vicinity, as described in IEC 60601-1 as six feet around a patient's chair or bed and do not touch the patient electronically and are grounded. These devices include operating room lighting, hospital carts and beds, automated dispensers of medication and supplies, and diagnostic equipment like x-ray machines. Type BF devices deliver electrical energy signals to or from the patient such as electrosurgical devices, endoscopes, and electrical vital sign monitors like thermometers. Type CF devices are similar to BF, except they supply power to devices connected to the heart, such as a defibrillator, external pacemaker or intracardiac ECG electrodes and Type CF requires a higher degree of protection against electrical shock than BF types.  
 

What is an open frame or internal AC-DC Power supply?

Open frame AC-DC power supplies are also known as AC-DC converters and are a type of internal power supply. The open frame AC to DC power supply is built into the inside of a system and used to convert the AC current into DC voltage.

How Does an AC-DC Adapter Work?

The AC to DC adapter or external power supply consists of a power supply which is enclosed in a housing similar to an AC plug, hence the term plug type, wall plug in, plug-in or plugtop power adapter. The power supply is plugged into the mains socket and the AC Voltage is then converted by the AC to DC adapter power supply into a DC voltage that is fed into the appliance via the output cable connection.

Request Info
Call
Email
💬
Text
💁
Chat
?
Request a Quote
Can we help you?
Can we help you?