GT-41052-WWVV-X.X-Q Class 2 Wall Plug-in ICT/ITE Power Supply Datasheet
GT-41052-WWVV-X.X-Q Class 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | GT-41052-WWVV-X.X-Q Class 2, ICT/ITE Power Supply, Wall Plug-in, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, Blade Options for Q Series Wall Plug-in Power Supplies, Output Rating: 15 Watts, Power rating with convection cooling (W) , 5-48V in 0.1V increments, Approvals: India BIS; cULus; cULus UL1310; Morocco; UKCA; Taiwan BSMI (5V only); CB 60950; CCC; CE; China RoHS; Double Insulation; FCC; GOST-R; IP52; Korea (5V Only); Korea (7V Only); Korea (9V Only); Korea (12V Only); Level IV; Level V (24-48V); Level V ,24V & 1830/; LPS 60950; NrCAN; PSE; RoHS; SIQ; Ukraine; VCCI; WEEE; RCM; GT-41052-WWVV-X.X-Q Class 2, ICT/ITE Power Supply, Wall Plug-in, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, Blade Options for Q Series Wall Plug-in Power Supplies, Output Rating: 15 Watts, Power rating with convection cooling (W) , 5-48V in 0.1V increments, Approvals: India BIS; cULus; cULus UL1310; Morocco; UKCA; Taiwan BSMI (5V only); CB 60950; CCC; CE; China RoHS; Double Insulation; FCC; GOST-R; IP52; Korea (5V Only); Korea (7V Only); Korea (9V Only); Korea (12V Only); Level IV; Level V (24-48V); Level V ,24V & 1830/; LPS 60950; NrCAN; PSE; RoHS; SIQ; Ukraine; VCCI; WEEE; RCM; | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Information | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Model Number | GT-41052-WWVV-X.X-Q Class 2 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Agency Documents | http://www.globtek.info/certs/GT-41052/ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
CE EC-Declaration for Medical | Contact GlobTek for more information | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
CE EC-Declaration for Industrial/Commercial/ITE | https://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000MEtWXEA1 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
CE EC-Declaration for Household | Contact GlobTek for more information | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
UKCA-Declaration for Medical | Contact GlobTek for more information | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
UKCA-Declaration for Industrial/Commercial/ITE | https://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000MEtWXEA1 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
UKCA-Declaration for Household | Contact GlobTek for more information | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Morocco SDoC Declaration | https://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0Oa000000MEtWXEA1 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
RoHS/RoHS3 Declaration | https://www.globtek.com/pdf/rohs_cert/a0Oa000000MEtWXEA1 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Prop 65 Statement | https://en.globtek.com/prop-65-statement.pdf | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
REACH Declaration | https://www.globtek.com/pdf/iso_certificates/REACH.pdf | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Conflict Minerals Declaration | https://www.globtek.com/pdf/conflict-minerals.pdf | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Model Parameters | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Type | Wall Plug-in | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Technology | Regulated Switchmode AC-DC Power Supply AC Adaptor | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Category | ICT/ITE Power Supply | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Input Voltage Range (V) | 100-240V~, 50-60 Hz | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Max Input Current (A) | 0.6 A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Max Output Power Rating (W) | 15 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Output Voltage Range (V) | 5-48 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Efficiency | V/IV see Approvals | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Ingress Protection | IP52 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Size (mm) | 43.5* 74.0* 35.3 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Enclosure | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Rating Table | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
* (Final ordering #/Part No to be defined) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Specifications | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
A) ELECTRICAL SPECIFICATIONS: 01. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac 02. Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz 03. Output Load Regulation: +/- 5% measured at the output connector 04. Line Voltage Regulation: +/- 1% typical measured at the output connector 05. Output Ripple (Vp-p): +/-1% or 150 mV whichever is greater at nominal output voltage, measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with 10 uf electrolytic capacitor connected at the end of the output connector 06. Turn-ON/OFF Overshoot: 5% maximum, 500uS max recovery time for 25% step load 07. Turn-ON Delay: 3000 mS, maximum 08. Hold-Up Time: 10 mS minimum at nominal input and full load 09. Inrush Current: 30A maximum at cold start 120VAC, 60A maximum cold start 230VAC 10. Switching Frequency: 66.5 KHz typical B) PROTECTION 01. Over-Voltage:Protected. Unit will auto recover upon removal of fault 02. Over current: Protected. Unit will auto recover upon removal of fault 03. Short Circuit: Protected. Unit will auto recover upon removal of fault 04. Input Protection: Input line fusing C) SAFETY 01. Dielectric Withstand Voltage: 4242Vdc from primary to secondary 02. Touch Current: <0.25mA @ 240Vac input voltage D) OTHER: 01. MTBF: 200,000 Hours @ 25°C ambient temperature 02. Operating Temperature: 0°C to 40°C ambient temperature 03. Humidity: 0% to 90% relative humidity 04. Storage Temperature: -10°C to 80°C 05. Cooling: Convection 06. RoHS 2: Complies with EU 2011/65/EU and China SJ/T 11363-2006 E) ENCLOSURE 01. Housing: High impact plastic, 94V0 polycarbonate, non-vented 02. Size: 43.5 x 74.0 x 35.3+/-1.0 mm 03. Markings: Label and/or Pad Printed and/or Molded in the case | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Derating Curve | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Qty (ea.)/Carton | 80 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Individual Box/Gift Box Size (mm) | 90.5 x 73 x 53 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Individual Box/Gift Box Color | White | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Master Carton Size (mm) | 388 x 380 x 245 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Gross Weight (kg) | 15.2 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Label Width (mm) | 29.8 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Label Height (mm) | 20.8 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Input Configuration | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Description | Blade Options for Q Series Wall Plug-in Power SuppliesData Sheet: http://en.globtek.com/interchangeable-blades.php Insertion Instructions: http://www.globtek.com/pdf/Instructions-Interchangeable-Blades.pdf Video: Q-Blade Style Instruction Video INPUT CONNECTOR: Q-Socket (below are available blades configurations which are "not included" (unless stated above); can be purchased separately, package with power supply or as a separate "Q-KIT" if specified 01. United States / Canada / Japan NEMA 1-15P/ IEC PLUG Type A [WORKS IN PLUG B] configuration: NA 2 blades, Class II; US/CA/JP P/N: Q-NA(R) Kits 01. Q-KIT: 1,2,3,4 above | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Output Configuration | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Common output connector options: Click to add to your request.
For a comprehensive list of options, click here Contact GlobTek for your specific requirements or custom solutions. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Approvals | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice. Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||