Description | GT-81087-20VV-x.x-W2U, ICT/ITE Power Supply, Wall Plug-in, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, UK BS 1363, 2 Blade w/Dummy Ground Class II, Output Rating: 20.4 Watts, Power rating with convection cooling (W) , 5-18V in 0.1V increments, Approvals: CE; RoHS; UKCA; WEEE; IP41; LPS 60950; Level V; China RoHS; Double Insulation; | ||||||||||||||||||||||||||||||||||||||||
Agency Documents | http://www.globtek.info/certs/GT-81087/ | ||||||||||||||||||||||||||||||||||||||||
CE EC-Declaration for Medical | Contact GlobTek for more information | ||||||||||||||||||||||||||||||||||||||||
CE EC-Declaration for Industrial/Commercial/ITE | Contact GlobTek for more information | ||||||||||||||||||||||||||||||||||||||||
CE EC-Declaration for Household | Contact GlobTek for more information | ||||||||||||||||||||||||||||||||||||||||
UKCA-Declaration for Medical | Contact GlobTek for more information | ||||||||||||||||||||||||||||||||||||||||
UKCA-Declaration for Industrial/Commercial/ITE | Contact GlobTek for more information | ||||||||||||||||||||||||||||||||||||||||
UKCA-Declaration for Household | Contact GlobTek for more information | ||||||||||||||||||||||||||||||||||||||||
Morocco SDoC Declaration | https://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0Oa000000BzyFLEAZ | ||||||||||||||||||||||||||||||||||||||||
RoHS/RoHS3 Declaration | https://www.globtek.com/pdf/rohs_cert/a0Oa000000BzyFLEAZ | ||||||||||||||||||||||||||||||||||||||||
Prop 65 Statement | https://en.globtek.com/prop-65-statement.pdf | ||||||||||||||||||||||||||||||||||||||||
REACH Declaration | https://www.globtek.com/pdf/iso_certificates/REACH.pdf | ||||||||||||||||||||||||||||||||||||||||
Conflict Minerals Declaration | https://www.globtek.com/pdf/conflict-minerals.pdf | ||||||||||||||||||||||||||||||||||||||||
Model Parameters | |||||||||||||||||||||||||||||||||||||||||
Type | Wall Plug-in | ||||||||||||||||||||||||||||||||||||||||
Technology | Regulated Switchmode AC-DC Power Supply AC Adaptor | ||||||||||||||||||||||||||||||||||||||||
Category | ICT/ITE Power Supply | ||||||||||||||||||||||||||||||||||||||||
Input Voltage Range (V) | 100-240V~, 50-60 Hz | ||||||||||||||||||||||||||||||||||||||||
Max Input Current (A) | 0.7A | ||||||||||||||||||||||||||||||||||||||||
Max Output Power Rating (W) | 20.4 | ||||||||||||||||||||||||||||||||||||||||
Output Voltage Range (V) | 5-18 | ||||||||||||||||||||||||||||||||||||||||
Efficiency | V | ||||||||||||||||||||||||||||||||||||||||
Ingress Protection | |||||||||||||||||||||||||||||||||||||||||
Size (mm) | 74*46*35 | ||||||||||||||||||||||||||||||||||||||||
Enclosure | Size: 73.5*54.0*49.9 ±1.0 mm | ||||||||||||||||||||||||||||||||||||||||
Rating Table | |||||||||||||||||||||||||||||||||||||||||
* (Final ordering #/Part No to be defined)
| |||||||||||||||||||||||||||||||||||||||||
Specifications | |||||||||||||||||||||||||||||||||||||||||
A) ELECTRICAL SPECIFICATIONS:
01. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac 02. Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz 03. Output Regulation: +/- 5% measured at the output connector 04. Line Voltage Regulation: +/- 2% typical measured at full load 05. Output Ripple (Vp-p): 200mV p-p measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with 10 uf electrolytic capacitor connected at the end of the output connector at nominal line 06. Turn-ON/OFF Overshoot: ± 10% maximum, 500 uS typical recovery time for 25% to 50% step load 07. Turn-ON Delay: 4 sec, maximum @ full load, nominal line 08. Hold-Up Time: 100 mS typical @ nominal input voltage and full load 09. Inrush Current: 150A maximum cold start @ 115/230Vac input 10. Switching Frequency: 65 KHz typical B) PROTECTION 01. Over-Voltage: Electronically Protected unit will auto recover upon removal of fault 02. Short Circuit: Electronically Protected unit will auto recover upon removal of fault 03. Input Protection: Input line fusing C) SAFETY 01. Dielectric Withstand Voltage: 4242Vdc from primary to secondary 02. Touch Current: <0.25mA @ 240Vac input voltage D) OTHER: 01. MTBF: 200,000 Hours @ 25°C ambient temperature 02. Operating Temperature: 0°C to 40°C ambient temperature 03. Humidity: 5% to 90% relative humidity 04. Storage Temperature: -20°C to 60°C 05. Cooling: Convection 06. ROHS 2: Complies with EU 2011/65/EU and China SJ/T 11363-2006 E) ENCLOSURE 01. Housing: High impact plastic, 94V0 polycarbonate, non-vented 02. Markings: Label and/or Pad Printed and/or Molded in the case | |||||||||||||||||||||||||||||||||||||||||
Derating Curve | |||||||||||||||||||||||||||||||||||||||||
Qty (ea.)/Carton | 120 | ||||||||||||||||||||||||||||||||||||||||
Individual Box/Gift Box Size (mm) | 95 x 54 x 68 | ||||||||||||||||||||||||||||||||||||||||
Individual Box/Gift Box Color | White | ||||||||||||||||||||||||||||||||||||||||
Master Carton Size (mm) | 495 x 345 x 308 | ||||||||||||||||||||||||||||||||||||||||
Gross Weight (kg) | 15.6 | ||||||||||||||||||||||||||||||||||||||||
Label Width (mm) | 38.7 | ||||||||||||||||||||||||||||||||||||||||
Label Height (mm) | 22.3 | ||||||||||||||||||||||||||||||||||||||||
Input Configuration | |||||||||||||||||||||||||||||||||||||||||
Description | UK BS 1363, 2 Blade w/Dummy Ground Class II The line and neutral pins have a rectangular cross section 6.35 mm by 4.0 mm, 17.7 mm long and with centres 22.2 mm apart. The protective-earth pin is a rectangular cross section 8.0 mm by 4.0 mm, 22.3 mm long and with a centre line 22.2 mm from the line/neutral pin centre line. The dimensions were originally specified in decimal inches with asymmetric tolerances and redefined as minimum and maximum metric dimensions in BS 1363:1984. Dimensions are chosen to provide safe clearance to live parts. The distance from any part of the line and neutral pins to the periphery of the plug base must be not less than 9.5 mm. This ensures that nothing can be inserted alongside a pin when the plug is in use, and helps keep fingers away from the pins. The minimum insertion distance from the face of the socket-outlet to the first point of contact with a live part is 9.6 mm. The "Dummy" longer earth pin ensures that the earth path is connected before the live pins, and remains connected after the live pins are removed. The earth pin is too large to be inserted into the line or neutral sockets by mistake. | ||||||||||||||||||||||||||||||||||||||||
Output Configuration | |||||||||||||||||||||||||||||||||||||||||
Common output connector options: Click to add to your request.
For a comprehensive list of options, click here Contact GlobTek for your specific requirements or custom solutions. | |||||||||||||||||||||||||||||||||||||||||
Approvals | |||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||
Popular Products (Stock items) | |||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||
News Releases | |||||||||||||||||||||||||||||||||||||||||
|
What is a Plug-in AC-DC Adapter?
Plug in AC-DC adapters are also known as AC Adaptors or AC-DC converters and are a type of external power supply. Some electrical appliances require power but lack the internal components to derive the required voltage and power from mains power. This is where an AC adapter is used to convert the AC current into DC voltage
How Does an AC-DC Adapter Work?
The AC to DC adapter or external power supply consists of a power supply which is enclosed in a housing similar to an AC plug, hence the term plug type, wall plug in, plug-in or plugtop power adapter. The power supply is plugged into the mains socket and the AC Voltage is then converted by the AC to DC adapter power supply into a DC voltage that is fed into the appliance via the output cable connection.