Request Information Download PDF Configure Output Connector
GTM91120-30VV-P2 GTM91120-30VV-P2
Information
Model NumberGTM91120-30VV-P2
DescriptionGTM91120-30VV-P2, ITE / Medical Power Supply, 60601-1-4th Ed. , Potted/Encapsulated in plastic housing, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, See "Blade/Cord Installed" section, Output Rating: 30 Watts, 5-48V in 0.1V increments, Approvals: CB EN/IEC 60335-1 CB CB CE CE China RoHS Double Insulation FCC GOST-R IP68 Level V PSE RoHS 2 SIQ SIQ Ukraine VCCI WEEE cRUus cRUus SIQ CE ETL CB LPS
Agency Documentshttp://www.globtek.info/certs/GTM91120-T2%20-T3A%20-FW/
CE EC-Declaration for Medicalhttp://globtek.force.com/models/ec_declaration?id=a0O30000008V8P7EAK
CE EC-Declaration for Industrial/Commercial/ITEhttp://globtek.force.com/models/ec_declaration?id=a0O30000008V8P7EAK
RoHS/RoHS3 Declarationhttp://www.globtek.com/pdf/rohs_cert/a0O30000008V8P7EAK
REACH Declarationhttp://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttp://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypePotted/Encapsulated in plastic housing
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor
CategoryITE / Medical Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)1.5A
Max Output Power Rating (W)30
Output Voltage Range (V)5-48
EfficiencyV
Ingress Protection
Size (mm)102*46*37
EnclosureUser-added image

                  MYLAR CASE COVER INSTALLED
Rating Table
Model Number VoltageAmps (A)Watts (W) RFQ
GTM91120-3007.5-1.5-P2 RFQ
GTM91120-3007.5-2.5-P2 5420 RFQ
GTM91120-0607.5-1.5-P2 616 RFQ
GTM91120-2207.5-1.5-P2 63.7522.5 RFQ
GTM91120-3010.5-1.5-P2 92.7724.93 RFQ
GTM91120-3014.5-2.5-P2 122.530 RFQ
GTM91120-3019.5-4.5-P2 15230 RFQ
GTM91120-3019.5-1.5-P2 181.6629.88 RFQ
GTM91120-3024-P2 241.2530 RFQ
GTM91120-3036-P2 360.8329.88 RFQ
GTM91120-3048-P2 480.62530 RFQ
SpecificationsA) ELECTRICAL SPECIFICATIONS:
1. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac
2. IInput Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz
3. Output Regulation: +/- 5% measured at the output connector
4. Line Voltage Regulation: +/- 2% typical measured at full load
5. Output Ripple (Vp-p): +/-2% maximum, measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with 10 uf electrolytic capacitor connected at the end of the output connector at nominal line
Optional low ripple option available (RFP4579)
6. Turn-ON/OFF Overshoot: 5% maximum, 500uS typical recovery time for 25% to 50% step load
7. Turn-ON Delay: 3 Seconds, maximum @ full load, nominal line
08. Hold-Up Time: 5mS typical @ nominal input voltage and full load
09. Inrush Current: 60A maximum cold start @ 240Vac input
10. Switching Frequency: 100 KHz typical

B) PROTECTION
1. Over-Voltage: Protected with a Zener diode clamp across the output
2. Short Circuit: Hiccup with auto recovery
3. Over-load: Hiccup with auto recovery
4. Input Protection: Input line and neutral fusing

C) SAFETY
1. Dielectric Withstand Voltage: 5656Vdc from primary to secondary
2. Earth Leakage Current: N/A for Class II units, there is no PE Ground pin, so Earth Leakage current is not measured
3. Touch Current: Maximum allowed values: 100uA NC(Normal condition) 500uA SFC(single fault condition)

D) OTHER:
1. MTBF: 200,000 Hours @ 25°C ambient temperature
2. Operating Temperature: -10°C to 40°C ambient temperature (RFP RFI-50576)
3. Humidity: 0% to 90% relative humidity
4. Storage Temperature: -10°C to 80°C
5. Cooling: Convection
6. ROHS 2: Complies with EU 2011/65/EU and China SJ/T 11363-2006
7. For EMI suppression 28A026-0A2 Snap-on Ferrites are recommended on both input and output cables, if required.

E) ENCLOSURE
1. Housing: High impact plastic, 94V0 polycarbonate, non-vented
2. Size: 97.23 x 46.23 x 32.0 +/- 1.0 mm
3. Markings: Label and/or Pad Printed and/or Molded in the case
4. Ingress Protection: IP68, Dust Tight, No ingress of dust, complete protection against contact as well as Protected against liquid Immersion beyond 1 m
Derating CurveUser-added image
Qty (ea.)/Carton45
Individual Box/Gift Box Size (mm)142 x 62 x 80
Individual Box/Gift Box ColorWhite
Master Carton Size (mm)462 x 360 x 295
Gross Weight (kg)15.2
Label Width (mm)59.5
Label Height (mm)29.5
Input Configuration
DescriptionSee "Blade/Cord Installed" section
Output Configuration
Common output connector options:
Click to add to your request.






L Type (Coaxial 5.5x2.5mm plug) C Type (Coaxial 5.5x2.1mm plug) K Type (Coaxial 3.5x1.3mm plug) LL Type (5.5x2.5mm Locking 760k type) CL Type (5.5x2.1mm Locking S761k type) Magnetic Connector





YL3 Type (KPPX-3P) YL4 Type (KPPX-4P) EJ1/2/3/4/5 (EIAJ RC-5320A type connectors) MSB Type (Micro USB) Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals
LogoDescription
User-added imageAttention Mark / Refer to operating manual for operating and service instructions
User-added imageBook 60335 up to 36 Volts
User-added image60601-1 3rd Operating Instructions
No Logo ApplicableCB report IEC 60601-1: 2005 + CORR. 1 (2006) + CORR. 2 (2007) and or EN 60601-1:2006 3rd Edition including 2MOOP requirements

No Logo Applicable

IEC 60335-1:2010 (Fifth Edition) incl. Corr. 1:2010 and Corr. 2:2011 + A1:2013
No Logo CB Certificate IEC 60950-1:2005 (2nd Edition), Am 1: 2009, CB report IEC 60950-1:2005 (2nd Edition), Am 1: 2009 and EN 60950-1:2006 + Am 1:2010 + Am 11:2009 + Am 12:2011

No Logo Applicable

CB to 60335-1 5th Edition (Safety of Household and Similar Electrical Appliances, Part 1: General Requirements) CB Report/ Certificate IEC 60335-1:2010 Up to 36 volts only
User-added image  CE Mark: tested to comply with EN 55032:2012+AC:2013, EN 61000-3-2:2014, EN 61000-3-3:2013, EN 55024:2010, EN 60601-1-2:2015
User-added image  CE Mark: tested to comply with EN55022:2006/A1:2007 Class B, EN610003-2, EN610003-3 including EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6N EN61000-4-11; EMI: Complies with EN55011 CLASS B and FCC Part 15B - On label or Molded in case
User-added image  CE Mark: tested to comply with EN61000-3-2, EN61000-3-3 and EN50082-1, including EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61001-1-2-2007 EMI: Complies with EN55011 CLASS B and FCC Part 15 B
User-added imageIEC 60601-1-11 Issued: 2015/01/20 Ed. 2 Medical Elec. Equip.- Part 1-11: Gen. Req. for Basic Safety &Essential Perf.- Collateral Standard - Req. for Medical Elec. Equip. & Medical Elec.Systems Used in the Home Healthcare Environment
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
User-added image
cRUus Registered E170507 CSA C22.2 No. 60950-1 2nd Ed.
User-added imagecRUus UL Recognized Component E172861 3rd Edition w-RM ANSI-AAMI ES60601-1 (2005 + C1:09 + A2:10) and CAN-CSA-C22.2 No. 60601-1 (2008)
User-added image

Double Insulation - Mark is on the label or Molded in the case
User-added image
FCC PART 15 CLASS B
User-added image
 
GOST-R mark for Russia(Document: http://www.globtek.com/html/iso_certificates/GT_GOST-R.pdf). 03/15/2015. Due to lack of demand, GlobTek will not be renewing it's GOST certification. Please contact your sales engineer for pricing on EAC.
User-added image
IEC/EN60335-1 Up to 36 volts
User-added image
IEC/EN60601-1
User-added image
IEC/EN60950-1
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
IP68Ingress Protection: IP68 to IEC60529:2001 Totally dust tight and Protected against long periods of immersion under pressure
 User-added image

Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
LPSLimited Power Source
User-added imageJAPAN TUV Rheinland-PSE GlobTek Inc to J60950-1(H26) , J55022(H22),J3000(H25).Please follow the procedure listed in the following link for proper import to Japan: http://en.globtek.com/importing-to-japan.php.
User-added imageRCM certificate SAA150575; Australia and New Zealand Regulatory Compliance, Mark (http://rcm.standards.org.au/rcmfaq/rcmfaq.htm)
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added image
Serial Number Information
User-added image
IEC/EN60335-1
SIQ IEC/EN 60335-1 (Safety of Household and Similar Electrical Appliances, Part 1: General Requirements) up to 36 volts
User-added image
IEC/EN60950-1
SIQ Mark License Certificate EN 60950-1:2006 + Am 1:2010+ Am 11:2009 + Am 12:2011
User-added image
IEC/EN60601-1
SIQ Mark License EN60601-1, 3rd edition
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products
SKUVolts OutCurrent Out (Amps)Connector
110134122.5Female Barrel 5.5 * 2.5 * 10mm with internal Spring Clip and Locking Notch or Equal
210368122.5Kycon # KPP-3P, DC Power Connectors 3P Power Plus Snap and Lock or Equal
181913122.5Female Barrel 3.5*1.35*9.5mm, without Locking Notch nor Spring Clip or Equal
274152122.5Female Barrel 5.5*3.3*9.5mm w/1.0 mm Pin or Equal
183796120.3Stripped & Tinned wires: ROJ: 50mm and RIJ: 19mm, Tolerance: +5mm, -0mm
149487122.5Stripped 7 +/- 1mm
183810152Stripped 7 +/- 1mm
202657241.25Stripped 7 +/- 1mm
18288454Stripped 7 +/- 1mm
24241061.0CELEC NINGBO FEMALE WATERPROOF CONN, 2 POS PN: 38141_20A105 with GOLD BRASS CONTACTS
20584361.0CELEC NINGBO FEMALE WATERPROOF CONN, 2 POS PN: 38141_20A105 with GOLD BRASS CONTACTS
20584261.0CELEC NINGBO FEMALE WATERPROOF CONN, 2 POS PN: 38141_20A105 with GOLD BRASS CONTACTS
19093663.75Stripped 25 +/- 5mm; Tinned 6 +/- 1mm or Equal
18212961.0SK2/2 OR EQUIVALENT: MALE WATERPROOF 2 PIN CONNECTOR.
16592961.0CELEC NINGBO FEMALE WATERPROOF CONN, 2 POS PN: 38141_20A105 with GOLD BRASS CONTACTS
12906561.0CELEC NINGBO FEMALE WATERPROOF CONN, 2 POS PN: 38141_20A105 with GOLD BRASS CONTACTS
12906461.0CELEC NINGBO FEMALE WATERPROOF CONN, 2 POS PN: 38141_20A105 with GOLD BRASS CONTACTS
News Releases
TitleWeb Link
CB Certificate IEC 60335-1:2010 (5th ed.) CB report IEC 60335-1:2010 (5th Ed.) and EN 60335- 1:2012.
IP68 Waterproof Switching Power Supply Ac Adapter in Class I or II configuration 30W (Watt) replaces generic desktop power supplies for use in environments requiring ruggedized configurations, model GTM91120-P2 –P3 Serieshttp://en.globtek.com/news.php/ip68-waterproof-switching-power-supply-ac-adapter-in-class-i-or-ii-configuration-30w-watt-replaces-generic-desktop-power-supplies-for-use-in-environments-requiring-ruggedized-configurations-model-gtm91120-p2-p3-series#.UlLBy
30w (Watt) Wall Plug In LPS Power Supply in Class I or Class II globally and internationally approved and certified for most global markets, model GTM91120 Series.http://en.globtek.com/news.php/30w-watt-wall-plug-in-lps-power-supply-in-class-i-or-class-ii-globally-and-internationally-approved-and-certified-for-most-global-markets-model-gtm91120-series

Request Info

Text us your inquiry