Request Information Download PDF Configure Output Connector
GTM91099-60VV-T2-IM GTM91099-60VV-T2-IM
Information
Model NumberGTM91099-60VV-T2-IM
DescriptionGTM91099-60VV-T2-IM, ITE / Medical Power Supply, 60601-1-4th Ed. , Wall Plug-in+Desktop Combination, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C8 AC Inlet connector, Output Rating: 60 Watts, 12-24V in 0.1V increments, Approvals: CB Level V EC Ukraine WEEE Double Insulation CE China RoHS NEMKO RCM PSE VCCI RoHS 2 LPS CE cRUus cUL ETL CE S-Mark IEC/EN 60601-1 EAC FCC IP54 CB 60601-1 2MOPP
Agency Documentshttp://www.globtek.info/certs/GTM91099/
CE EC-Declaration for Medicalhttp://globtek.force.com/models/ec_declaration?id=a0Oa000000C1e9DEAR
CE EC-Declaration for Industrial/Commercial/ITEhttp://globtek.force.com/models/ec_declaration?id=a0Oa000000C1e9DEAR
RoHS/RoHS3 Declarationhttp://www.globtek.com/pdf/rohs_cert/a0Oa000000C1e9DEAR
REACH Declarationhttp://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttp://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeWall Plug-in+Desktop Combination
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor
CategoryITE / Medical Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)1.5A
Max Output Power Rating (W)60
Output Voltage Range (V)12-24
EfficiencyV
Ingress Protection
Size (mm)117.53*53.47*36.6
EnclosureUser-added image
User-added image
 
Rating Table
Model Number VoltageAmps (A)Watts (W) RFQ
GTM91099-3009-4.0-T2 5630 RFQ
GTM91099-4509-T2 9545 RFQ
GTM91099-6015-3.0-T2 12560 RFQ
GTM91099-6015-T2 15460 RFQ
GTM91099-6024-T2 242.560 RFQ
GTM91099-6048-T2 481.2560 RFQ
SpecificationsA) ELECTRICAL SPECIFICATIONS:
01. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac
02. Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz
03. Output Regulation: +/- 5% nominal output voltage measured at the output connector at nominal line
04. Line Voltage Regulation: +/- 2% max at full load
05. Output Ripple (Vp-p): +/-1% or 150mV whichever is greather at nominal output voltage. Measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with 10 uf electrolytic capacitor connected at the end of the output connector.
06. Turn-ON/OFF Overshoot: 5% max, 500uS max recovery time for 25% to 50% step load
07. Turn-ON Delay: 2 Seconds, maximum @ full load, nominal line
08. Hold-Up Time: 8 mS at nominal input and full load
09. Inrush Current: 40A max at cold start 120 VAC, 60A max cold start 230VAC
10. Switching Frequency: 100 KHz typical

B) PROTECTION
1. Over-Voltage: Protected, Hiccup with auto recovery
2. Short Circuit: Protected, Hiccup with auto recovery
3. Over-load: Protected, Hiccup with auto recovery
4. Input Protection: Input line and neutral fusing
5. Means of Patient Protection: (2 x MOPP)

C) SAFETY
01. Dielectric Withstand Voltage: 5656Vdc from primary to secondary
02. Touch Current: Maximum allowed values: 100uA NC(Normal condition) 500uA SFC(single fault condition)
03. Means of Protection: 2 x MOPP
04. Primary to Secondary Bridging Capacitor: (2) * Y1 type capacitors in series

D) OTHER:
1. MTBF: 200,000 Hours @ 25°C ambient temperature
2. Operating Temperature: 0°C to 40°C ambient temperature
3. Humidity: 0% to 90% relative humidity
4. Storage Temperature: -10°C to 80°C
5. Cooling: Convection

E) ENCLOSURE
1. Housing: High impact plastic, 94V0 polycarbonate, non-vented
2. Size: 117.53*53.47*36.6 mm +/- 1.0
3. Markings: Label and/or Pad Printed and/or Molded into Case
4. LED: Standard Green color to indicate power on
Derating CurveUser-added image
     Note:
     @ 15W UL certified to +70C for GTM91099-3009-4.0 only
Qty (ea.)/Carton
Individual Box/Gift Box Size (mm)
Individual Box/Gift Box Color
Master Carton Size (mm)TBD
Gross Weight (kg)
Label Width (mm)44.5
Label Height (mm)49.5
Input Configuration
DescriptionIEC 60320/C8 AC Inlet connectorBlade Insertion Instructions
R-Blade Style Instruction Video

User-added image
Mates with IEC 60320/C7 Plug

This series of Interchangeable Blade products may be used with Proprietary Interchangeable Blades as described below or with standard international power cords.
 
Optional INPUT BLADES: R-Socket: below are available blades configurations which are "not included" (unless stated above); may be purchased separately, packaged with power supply, or as a separate "R-KIT" if specified 
1. Class II model NEMA 1-15P AC power plug with 2 prongs, R-NA-2(R) 
2. Australian AS 3112 configuration: SAA 2 pins Class II, R-SAA-2(R) 
3. UK BS 1363 configuration: UK 2 pins (dummy Ground) Class II, R-UK-2(R) 
4. European CEE 7/16 configuration: Europlug 2 PINS, Class II, R-EU-2(R) 
5. China GB 2099 configuration: 2 blades, Class II; CN P/N:R-CN-2(R)
6. Desktop Insert
Kits
05. R-KIT: 1,2,3,4 above
06. R-KIT-INTL: 2,3,4 above

User-added image

Standard Cordsets
Below are standard cordsets which are "not included" (unless stated above); these may be purchased separately or packaged with the power supply. Contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material.

Standard International IEC 320/C7 Cordsets
4511116F703A(R)N. AmericanNEMA 1-15PIEC 320/C718306
5014112M703A(R)AustralianAS 3112IEC 320/C720007
2094112M703(R)ArgentinaIRAM 2063IEC 320/C720007
4533501M8703(R)ChinaGB 2099.1IEC 320/C718306
2074112M703A(R)EuropeanCEE 7/16IEC 320/C720007
451J3401M8703(R)JapanJIS 8303IEC 320/C718306
6104112M703A(R)UKBS1363IEC 320/C720007
Output Configuration
Common output connector options:
Click to add to your request.






L Type (Coaxial 5.5x2.5mm plug) C Type (Coaxial 5.5x2.1mm plug) K Type (Coaxial 3.5x1.3mm plug) LL Type (5.5x2.5mm Locking 760k type) CL Type (5.5x2.1mm Locking S761k type) Magnetic Connector





YL3 Type (KPPX-3P) YL4 Type (KPPX-4P) EJ1/2/3/4/5 (EIAJ RC-5320A type connectors) MSB Type (Micro USB) Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals
LogoDescription
User-added imageAttention Mark / Refer to operating manual for operating and service instructions
User-added imageBook 60335 up to 36 Volts
User-added image60601-1 3rd Operating Instructions
No Logo ApplicableIEC 60601-1: 2005 + C1 + C2 + A1
No Logo ApplicableCB report IEC 60601-1: 2005 + CORR. 1 (2006) + CORR. 2 (2007) and or EN 60601-1:2006 3rd Edition
User-added image  CE Certification
User-added image  CE Certification CE Mark: tested to comply with EN 55032.2012+AC.2013 EN 61000-3-2.2014 EN 61000-3-3.2013 EN 60601-1-2.2015 EN 55024.2010
User-added image  CE Mark: tested to comply with Additional EN610006-1:2007, EN610006-2:2005 EN61000-6-3:2007+A1:2011 EN61000-6-4:2007+A1:2011
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
User-added imagecRUus UL Recognized Component E341350 3rd Edition w-RM ANSI-AAMI ES60601-1 (2005 + C1:09 + A2:10) and CAN-CSA-C22.2 No. 60601-1 (2008)
User-added imageUL 60950-1, 2nd Edition, 2011-12-19 (Information Technology Equipment - Safety - Part 1: General Requirements) CSA C22.2 No. 60950-1-07, 2nd Edition, 2011-12 (Information Technology Equipment - Safety - Part 1: General Requirements)
User-added image

Double Insulation - Mark is on the label or Molded in the case
User-added image  Certification # TC RU C-US.AR46.B.79113 Custom Union of Russia, Belarus and Kazakhstan
No LogoEC-Conformity Declaration: http://www.globtek.com/html/iso_certificates/EC-DECLARATION.pdf, REACH 144 SVHC: http://www.globtek.com/html/iso_certificates/Reach144.pdf
User-added imageMedical Electrical Equipment – Part 1: General Requirement for Basic safety Essential Performance (AAMI ES60601-1:2005+A1) Medical Electrical Equipment – Part 1: General Requirement for Basic safety Essential Performance (CSA C22 2#60601-1:2014 Ed.3)
User-added imageFCC PART 15B Report STR14078169E-3
User-added image
IEC/EN60335-1 Up to 36 volts
User-added image
IEC/EN60601-1
User-added image
IEC/EN60950-1
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
IP54Ingress Protection: IP54 to IEC60529:2001 Protected against dust - limited ingress (no harmful deposit) and Protected against sprays from all directions - limited ingress permitted
 User-added image

Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
LPSLimited Power Source
Nemko
NEMKO
User-added imageJAPAN TUV Rheinland-PSE GlobTek Inc to J60950-1(H26) , J55022(H22),J3000(H25).Please follow the procedure listed in the following link for proper import to Japan: http://en.globtek.com/importing-to-japan.php.
User-added image
RCM N136; Australia and New Zealand Regulatory Compliance, Mark (http://rcm.standards.org.au/rcmfaq/rcmfaq.htm
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added imageSemko S-Mark-Cert-EN60601-1 and EN60950-1
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products
SKUVolts OutCurrent Out (Amps)Connector
149693183.3Female Barrel 5.5 * 2.5 * 11mm No internal Spring Clip nor Locking Notch or Equal
News Releases
TitleWeb Link
Encapsulated Potted Power Supply Ac Adapter Meets IP68 Ingress Protection Model Series GT(M)91099 -P2 –P3http://en.globtek.com/power-supplies.php/encapsulated-potted-power-supply-ac-adapter-meets-ip68-ingress-protection-model-series-gtm91099-p2-p3

Request Info