Request Information Download PDF Configure Output Connector
GTM96250-25VV-R2 GTM96250-25VV-R2
25W CF (Cardiac Floating) Rated Output Isolation Medical IEC60601 Power supply in a Desktop/Wall Plug In Hybrid Configuration
Information
Model NumberGTM96250-25VV-R2
DescriptionGTM96250-25VV-R2, CF Leakage Current Level, using Sigma Wave Technology, Medical Power Supply for Clinical or Home Use Application, Output Rating: 25 Watts, 5-48V in 0.1V increments.
Agency Documents
CE EC-Declaration for Medicalhttp://globtek.force.com/models/ec_declaration?id=a0Oa000000FjEyLEAV
CE EC-Declaration for Industrial/Commercial/ITEContact GlobTek for more information
RoHS/RoHS3 Declarationhttp://www.globtek.com/pdf/rohs_cert/a0Oa000000FjEyLEAV
REACH Declarationhttp://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttp://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeWall Plug-in+Desktop Combination
TechnologySigma Wave Ultra Low Leakage Current, CF Compliant Power Supply AC Adaptor
CategoryClass II Input Medical, Clinical or Home Use Application
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)1A
Max Output Power Rating (W)25
Output Voltage Range (V)5-48
EfficiencyVI
Ingress ProtectionIP41, IP52 Option available
Size (mm)(L)101.73x(W)46.47x(H)38.2mm
Enclosure
 User-added image


 
Rating Table
Model Number VoltageAmps (A)Watts (W) RFQ
GTM96250-2005-R2 5420 RFQ
GTM96250-2011-R2 111.81820 RFQ
GTM96250-2512-R2 122.08325 RFQ
GTM96250-2524-R2 241.04124.98 RFQ
GTM96250-2548-R2 480.52125.01 RFQ
SpecificationsA) ELECTRICAL SPECIFICATIONS:
01. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac
02. Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz
03. Output Regulation: +/- 5% measured at the output connector
04. Line Voltage Regulation: +/- 0.5% typical measured at full load
05. Green Power On Indicator LED
06. Output Ripple (Vp-p): 1% or 100 mV whichever is greater, measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with a low impedance 47 uf electrolytic capacitor connected at the end of the output connector
07. Turn-ON/OFF Overshoot: 5% maximum, 1 mS typical recovery time for 40% to 70% step load
08. Turn-ON Delay: 1 second maximum @ full load, 100Vac input
09. Hold-Up Time: 8 mS typical @ 100Vac input voltage and full load
10. Inrush Current: 30A/60A maximum cold start @ 115/230Vac input
11. Efficiency: Compliant with Worldwide Level VI standards.
12. No Load Standby Power: 75 mW max 
                                                   
B) PROTECTION
01. Over-Voltage: 110% to 130% of nominal output voltage
02. Short Circuit: Electronically Protected unit will auto recover upon removal of fault
                               Output Current Limit: 110% to 160% of rated output
03. Input Protection: Input line fusing and 300Vac MOV

C) SAFETY
01. Dielectric Withstand Voltage: 4000Vac or 5656Vdc from input to output
02.Output Floating , Touch Current: Class II models < 10uA
03. Output Floating or Earthed option for Class I models.
04. Means of Protection: 2 x MOPP
05. Output Isolation: CF
06. Compliant Standards: See listings at end of this drawing for specifics

D) EMC
EN 60601-1-2, 4th edition
Emissions, per EN 55032, EN61000-6-3, EN61000-6-4
  Conducted Emissions: Class B, FCC Part 15, Class B
  Radiated Emissions: Class B, FCC Part 15, Class B
  Line Frequency Harmonics EN61000-3-2, Class A
  Voltage Fluctuations/Flicker EN61000-3-3
 
Immunity, per EN 55024, EN61000-6-1, EN61000-6-2
  Static Discharge Immunity EN61000-4-2, 10kV Contact Discharge, 20kV air discharge
  Radiated RF Immunity EN61000-4-3, 10V/m 80-1000MHz, 3V/m 1-2.7GHz, 80% 1KHz AM.
  EFT/Burst Immunity EN61000-4-4, 4kV/25kHz.
  Line Surge Immunity EN61000-4-5, 2kV differential, 4kV common-mode
  Conducted RF Immunity EN61000-4-6, 3Vrms, 80% 1KHz AM
  Power Frequency Magnetic Field Immunity EN61000-4-8, 3A/m
  Voltage Dip Immunity EN61000-4-11, Criteria

E) OTHER:
01. MTBF: 300,000 Hours @ 25°C ambient temperature
02. Operating Temperature: 0°C to 40°C ambient temperature at full load, -10°C to 50°C ambient temperature with 80% load derating
03. Operating Humidity: 0% to 90% relative humidity
04. Storage Temperature: -10°C to 80°C
05. Operating Altitude: 5000 Meters
06. ROHS 2: Complies with EU 2011/65/EU and China SJ/T 11363-2006

F) ENCLOSURE
01. Housing: High impact plastic, 94V0 polycarbonate, non-vented
02. Markings: Label and/or Pad Printed and/or Molded in the case

G) SPECIAL OPTIONS
01. Cost reduction, removal of LED
02. Custom Cordsets, various cordage types, and connector types
03. Custom Markings
04. Short term Output Surge Capability
05. Custom Housing, with C18 Power Inlet
06. Tightened output voltage tolerance
07. Constant current battery charger characteristic
08. Reduced output power rating
08. High Rel PCB laminate with Plated through Holes for IPC610 Class 2 Compliance
09. Special Housing Colors and Cordset Colors
Derating CurveUser-added image
 
Qty (ea.)/Carton48
Individual Box/Gift Box Size (mm)Egg Crate
Individual Box/Gift Box Color
Master Carton Size (mm)442 x 330 x 275
Gross Weight (kg)15.2
Label Width (mm)37.5
Label Height (mm)33.5
Input Configuration
DescriptionIEC 60320/C8 AC Inlet connectorBlade Insertion Instructions
R-Blade Style Instruction Video

User-added image
Mates with IEC 60320/C7 Plug

This series of Interchangeable Blade products may be used with Proprietary Interchangeable Blades as described below or with standard international power cords.
 
Optional INPUT BLADES: R-Socket: below are available blades configurations which are "not included" (unless stated above); may be purchased separately, packaged with power supply, or as a separate "R-KIT" if specified 
1. Class II model NEMA 1-15P AC power plug with 2 prongs, R-NA-2(R) 
2. Australian AS 3112 configuration: SAA 2 pins Class II, R-SAA-2(R) 
3. UK BS 1363 configuration: UK 2 pins (dummy Ground) Class II, R-UK-2(R) 
4. European CEE 7/16 configuration: Europlug 2 PINS, Class II, R-EU-2(R) 
5. China GB 2099 configuration: 2 blades, Class II; CN P/N:R-CN-2(R)
6. Desktop Insert
Kits
05. R-KIT: 1,2,3,4 above
06. R-KIT-INTL: 2,3,4 above

User-added image

Standard Cordsets
Below are standard cordsets which are "not included" (unless stated above); these may be purchased separately or packaged with the power supply. Contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material.

Standard International IEC 320/C7 Cordsets
4511116F703A(R)N. AmericanNEMA 1-15PIEC 320/C718306
5014112M703A(R)AustralianAS 3112IEC 320/C720007
2094112M703(R)ArgentinaIRAM 2063IEC 320/C720007
4533501M8703(R)ChinaGB 2099.1IEC 320/C718306
2074112M703A(R)EuropeanCEE 7/16IEC 320/C720007
451J3401M8703(R)JapanJIS 8303IEC 320/C718306
6104112M703A(R)UKBS1363IEC 320/C720007
Output Configuration
Common output connector options:
Click to add to your request.






L Type (Coaxial 5.5x2.5mm plug) C Type (Coaxial 5.5x2.1mm plug) K Type (Coaxial 3.5x1.3mm plug) LL Type (5.5x2.5mm Locking 760k type) CL Type (5.5x2.1mm Locking S761k type) Magnetic Connector





YL3 Type (KPPX-3P) YL4 Type (KPPX-4P) EJ1/2/3/4/5 (EIAJ RC-5320A type connectors) MSB Type (Micro USB) Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals
LogoDescription
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
User-added image

Double Insulation - Mark is on the label or Molded in the case
 User-added image
 
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case

Request Info

Text us your inquiry