GT-93047-1005-W2E Wall Plug-in ICT/ITE Power Supply
GT-93047-1005-W2E | |||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
GT-93047-1005-W2E, ICT/ITE Power Supply, Wall Plug-in, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, European CEE 7/16 configuration:EN 50075 Europlug 2 PIN, Output Rating: 10 Watts, Power rating with convection cooling (W) , 5V in 0.1V increments, Approvals: Double Insulation; WEEE; RoHS; GOST-R; CE; EC; Level V; | |||||||||||||||||||||||
Information | |||||||||||||||||||||||
Model Number | GT-93047-1005-W2E | ||||||||||||||||||||||
CE EC-Declaration for Medical | Contact GlobTek for more information | ||||||||||||||||||||||
CE EC-Declaration for Industrial/Commercial/ITE | https://cs.globtek.info/ec_declaration?id=a0Oa000000JBNuhEAH | ||||||||||||||||||||||
CE EC-Declaration for Household | Contact GlobTek for more information | ||||||||||||||||||||||
UKCA-Declaration for Medical | Contact GlobTek for more information | ||||||||||||||||||||||
UKCA-Declaration for Industrial/Commercial/ITE | https://cs.globtek.info/ukca_declaration?id=a0Oa000000JBNuhEAH | ||||||||||||||||||||||
UKCA-Declaration for Household | Contact GlobTek for more information | ||||||||||||||||||||||
Morocco SDoC Declaration | https://cs.globtek.info/Morocco_SDoC_Declaration?id=a0Oa000000JBNuhEAH | ||||||||||||||||||||||
RoHS/RoHS3 Declaration | https://www.globtek.com/pdf/rohs_cert/a0Oa000000JBNuhEAH | ||||||||||||||||||||||
Prop 65 Statement | https://www.globtek.com/r2/PH7CNf | ||||||||||||||||||||||
REACH Declaration | https://www.globtek.com/r2/eM2co8 | ||||||||||||||||||||||
Conflict Minerals Declaration | https://www.globtek.com/r2/vZY8R5 | ||||||||||||||||||||||
Model Parameters | |||||||||||||||||||||||
Type | Wall Plug-in | ||||||||||||||||||||||
Technology | Regulated Switchmode AC-DC Power Supply AC Adaptor | ||||||||||||||||||||||
Category | ICT/ITE Power Supply | ||||||||||||||||||||||
Input Voltage Range (V) | 100-240V~, 50-60 Hz | ||||||||||||||||||||||
Max Input Current (A) | TBA | ||||||||||||||||||||||
Max Output Power Rating (W) | 10 | ||||||||||||||||||||||
Output Voltage Range (V) | 5 | ||||||||||||||||||||||
Efficiency | V | ||||||||||||||||||||||
Ingress Protection | IPx0 | ||||||||||||||||||||||
Size (mm) | 69*29*45 | ||||||||||||||||||||||
Enclosure | |||||||||||||||||||||||
Rating Table | |||||||||||||||||||||||
* (Final ordering #/Part No to be defined) | |||||||||||||||||||||||
Specifications | |||||||||||||||||||||||
A) ELECTRICAL SPECIFICATIONS: 01. Input Voltage: 100-240 Vac 02. Input Frequency: 47 - 63 Hz 03. Output Regulation: +/- 5% measured at the output connector 04. Line Voltage Regulation: +/- 2% typical measured at full load 05. Output Ripple (Vp-p): +/-1% or 120 mV whichever is greater, measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with 10 uf electrolytic capacitor connected at the end of the output connector at nominal line 06. Turn-ON/OFF Overshoot: 5% maximum, 1 mS typical recovery time for 25% to 50% step load 07. Turn-ON Delay: 1 Sec, typical @ full load, nominal line 08. Hold-Up Time: 5 mS typical @ nominal input voltage and full load 09. Switching Frequency: TBA KHz typical 10. Hold Up Time: Hold up time at full load (230VAC) and outage of one half wave (10 ms), the outage of one complete wave (20 ms), Hold up time of a voltage drop to 70 % during 25 waves (500 ms). 11. Efficiency: Compliant with Worldwide Level V standards. 12. No Load Standby Power: <0.3 W B) PROTECTION 01. Over-Voltage: Electronically Protected unit will auto recover upon removal of fault 02. Short Circuit: Electronically Protected unit will auto recover upon removal of fault 03. Input Protection: Input line fusing 04. Over Temperature protection: Electronically Protected unit will auto recover upon removal of fault C) SAFETY 01. Dielectric Withstand Voltage: 4242Vdc from primary to secondary 02. Earth Leakage Current: <0.25 mA at 264Vac input voltage D) OTHER: 01. MTBF: 200,000 Hours @ 25°C ambient temperature 02. Operating Temperature: 0°C to 40°C ambient temperature 03. Humidity: 0% to 90% relative humidity 04. Storage Temperature: -10°C to 80°C 05. Cooling: Convection 06. Ingress Protection: IPx0 07. Air pressure: 700 hPa to 1060 hPa (altitude range of -30 m to 3,000 m above sea level) 08. Direct sunlight: Meet or exceed tolerance of 700 W/m² E) ENCLOSURE 01. Housing: High impact plastic, 94V0 polycarbonate, non-vented 02. Size: 74.5*29.0*40.9 +/-1 1mm 03. Markings: Label and/or Pad Printed and/or Molded in the case 04. Drop testing: 1000mm drop height without any damage | |||||||||||||||||||||||
Derating Curve | |||||||||||||||||||||||
Qty (ea.)/Carton | 60 | ||||||||||||||||||||||
Individual Box/Gift Box Size (mm) | 100*58*90 | ||||||||||||||||||||||
Individual Box/Gift Box Color | White | ||||||||||||||||||||||
Master Carton Size (mm) | 465 x 416 x 225 | ||||||||||||||||||||||
Gross Weight (kg) | 16.5 | ||||||||||||||||||||||
Label Width (mm) | 21.2 | ||||||||||||||||||||||
Label Height (mm) | 30.0 | ||||||||||||||||||||||
Input Configuration | |||||||||||||||||||||||
Description | European CEE 7/16 configuration:EN 50075 Europlug 2 PINThe prongs of the Europlug are 19 mm long. They consist of a 9 mm long conductive tip of 4 mm diameter with a rounded ending, followed by a 10 mm long flexible insulated shaft of not more than 3.8 mm diameter. The two prongs are not exactly parallel and converge slightly; their centres are 19 mm apart at the tip and 18.6 mm apart at the base. The elasticity of the converging prongs provides sufficient contact force for the Europlug's current rating with a variety of socket-hole arrangements. The entire plug is 35.3 mm wide and 13.7 mm high, and must not exceed these dimensions within 18 mm behind its front plane (this allows for the recesses on many European socket types). The left and right side of the plug are formed by surfaces that are at 45° relative to the horizontal plan. | ||||||||||||||||||||||
Output Configuration | |||||||||||||||||||||||
Common output connector options: Click to add to your request.
Comprehensive list of GlobTek output cordset options Contact GlobTek for your specific requirements or custom solutions. | |||||||||||||||||||||||
Approvals | |||||||||||||||||||||||
Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice. Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation. | |||||||||||||||||||||||
|