GTM41133-90VV-x.x-F GTM41133-90VV-x.x-F
Information
Model NumberGTM41133-90VV-x.x-F
DescriptionGTM41133-90VV-x.x-F, Medical Power Supply, 60601-1-4th Ed. , Open Frame/Internal, Regulated Switchmode AC-DC, , Input Rating: 100-240V~, 50-400Hz, Tyco 640445-5 3 Position Header PIN 1: EARTH, PIN 3: LINE, PIN 5: NEUTRAL, remove Pins 2 and 4, Output Rating: 90 Watts, 12-48V in 0.1V increments, Approvals: CB CE CE cETLus ES60601 cETLus 60601-1 3rd ETL China RoHS Class I GOST-R Level V RoHS 2 Ukraine WEEE CB 60601-1 2MOPP S-Mark RCM CE CE Serbia S-Mark IEC/EN 60601-1 CB
Agency Documentshttp://globtek.info/certs/GTM41133/
CE EC-Declaration for Medicalhttp://globtek.force.com/models/ec_declaration?id=a0Oa000000JCFgXEAX
CE EC-Declaration for Industrial/Commercial/ITEContact GlobTek for more information
RoHS/RoHS2 Declarationhttp://www.globtek.com/pdf/rohs_cert/a0Oa000000JCFgXEAX
REACH Declarationhttp://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttp://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeOpen Frame/Internal
TechnologyRegulated Switchmode AC-DC
CategoryMedical Power Supply
Input Voltage100-240V~, 50-400Hz
I/P Amps (A)1.5A
Wattage (W)90
Vout Range (V)12-48
EfficiencyV
Ingress Protection
Size (mm)184*62*25
Enclosure
User-added image

 
Rating Table
Model Number VoltageAmps (A)Watts (W) RFQ
GTM41133-9016-4.0-F 127.590 RFQ
GTM41133-9016-1.0-F 151.0615.9 RFQ
GTM41133-9024-6.0-F 18590 RFQ
GTM41133-9024-5.0-F 194.7389.87 RFQ
GTM41133-9024-F 243.7590 RFQ
GTM41133-9048-12.0-F 362.590 RFQ
GTM41133-9048-10.5-F 37.52.490 RFQ
GTM41133-9048-F 481.87590 RFQ
SpecificationsA) ELECTRICAL SPECIFICATIONS:
01. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac
02. Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz
03. Output Regulation: +/- 5% measured at the output connector
04. Line Voltage Regulation: +/- 1% typical measured at full load
05. Output Ripple (Vp-p): +/-1% or 150 mV whichever is greater, measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with 10 uf electrolytic capacitor connected at the end of the output connector at nominal line
06. Turn-ON/OFF Overshoot: 5% maximum, 1 mS typical recovery time for 25% to 50% step load
07. Turn-ON Delay: 1 sec, maximum @ full load, nominal line
08. Hold-Up Time: 8 mS typical @ nominal input voltage and full load
09. Inrush Current: 30/60A maximum cold start @ 115/230Vac input
10. Switching Frequency: 65 KHz typical

B) PROTECTION
01. Over-Voltage: Electronically Protected Zener clamp across the output
02. Short Circuit: Electronically Protected unit will auto recover upon removal of fault
03. Input Protection: Input line fusing

C) SAFETY
01. Dielectric Withstand Voltage: 5656Vdc from primary to secondary
02. Earth Leakage Current: Did not exceed 5 mA in NORMAL CONDITION and 10 mA in SINGLE FAULT CONDITION
03. Earth continuity test:<0.1 Ohm or < 0.2 Ohm when with a non-detachable Power Supply cord, Class I Only
04 Touch Current: Did not exceed 100uA NC(Normal condition) 500uA SFC(single fault condition)
05. Primary to Secondary Isolation: 2 MOPP

D) OTHER:
01. MTBF: 200,000 Hours @ 25°C ambient temperature
02. Operating Temperature: 0°C to 40°C ambient temperature
03. Humidity: 0% to 90% relative humidity
04. Storage Temperature: -10°C to 80°C
05. Cooling: Convection
06. Operating Altitude: 5,000 METERS
07. Operating Atmospheric Pressure: 700 hPa TO 1060hPa

E) ENCLOSURE
01. Open Frame
02. Size: 156.0 x 55.2 x 24.1 +/-1.0 mm
03. LED to indicate "Power Out"
04. Markings: Label
Derating Curve
Qty (ea.)/Carton32
Individual Box/Gift Box Size (mm)Egg Crate
Individual Box/Gift Box Color
Master Carton Size (mm)470 x 370 x 210
Gross Weight (kg)15.6
Label Width (mm)30.0
Label Height (mm)23.0
Input Configuration
DescriptionTyco 640445-5 3 Position Header PIN 1: EARTH, PIN 3: LINE, PIN 5: NEUTRAL, remove Pins 2 and 4Product Details: http://www.te.com/catalog/pn/en/640445-5?RQPN=640445-5

User-added image
 
Approvals
LogoDescription
User-added image60601-1 3rd Operating Instructions
No Logo ApplicableCB report IEC 60601-1: 2005 + CORR. 1 (2006) + CORR. 2 (2007) and or EN 60601-1:2006 3rd Edition 2xMOPP
No Logo IEC 60601-1: 2005 and IEC 60601-1-11:2015

No Logo Applicable

IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013
User-added image  CE Certification CE Mark: tested to comply with EN 55032.2012+AC.2013 EN 61000-3-2.2014 EN 61000-3-3.2013 EN 60601-1-2.2015 EN 55024.2010
User-added image  CE Mark: tested to comply with EN55022:2006/A1:2007 Class B, EN610003-2, EN610003-3 including EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6N EN61000-4-11; EMI: Complies with EN55011 CLASS B and FCC Part 15B - On label or Molded in case
User-added image  CE Mark: tested to comply with EN 60601-1-2:2007 Medical electrical equipment Part 1-2: - Mark is on the label or Molded in the case
Conforms to ANSI/AAMI ES 60601-1:2005
Cert.to CAN/CSA Std. C22.2
 
cETLus ANSI_AAMI ES60601-1_2005
User-added image
 
cETLus-Cert-4007497 ANSI/AAMI ES60601-1:2005 with AMD C1: 2009, AMD C2: 2010 and CAN/CSA-C22.2 No. 60601-1 2008 with COR 2:2011+ANSI/AAMI HA60601-1-11 Ed:1 for T2 only
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
User-added image
Class I Earth Ground
User-added image  Certification # TC RU AR46.B.59626 Custom Union of Russia, Belarus and Kazakhstan
User-added imageInformation Technology Equipment Safety Part 1: General Requirements >Valid without technical revision: 01Jan2022< [UL 60950-1:2007 Ed.2 +R:14Oct2014]
User-added image
 
GOST-R mark for Russia(Document: http://www.globtek.com/html/iso_certificates/GT_GOST-R.pdf). 03/15/2015. Due to lack of demand, GlobTek will not be renewing it's GOST certification. Please contact your sales engineer for pricing on EAC.
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
 User-added image

Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
User-added imageRCM certificate SAA-170038-EA; Australia and New Zealand Regulatory Compliance, Mark (http://rcm.standards.org.au/rcmfaq/rcmfaq.htm)
RoHS 2RoHS 2: Complies with EU 2011/65/EU and CHINA SJ/T 11363-2006 http://www.ce-mark.com/Rohs%20final.pdf
User-added imageS-Mark Certificate EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011+A2:2013 (http://www.intertek.com/marks/s/)
User-added imageSemko S-Mark-Cert-EN60601-1 3rd Edition (http://www.intertek.com/marks/s/)
User-added imageSerbia Approval - Conformity mark must be at least 5 mm high.
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products
SKUVolts OutCurrent Out (Amps)Connector
176246127.5Tyco P/N 1-640445-4, 4 Position or equivalent
324237127.5Tyco P/N 1-640445-4, 4 Position or equivalent
189954156.0Tyco P/N 1-640445-4, 4 Position or equivalent
200561165.63Tyco P/N 1-640445-4, 4 Position or equivalent
177297185.0Tyco P/N 1-640445-4, 4 Position or equivalent
175014243.75Tyco P/N 1-640445-4, 4 Position or equivalent
217031243.75Tyco P/N 1-640445-4, 4 Position or equivalent
19888524.73.64Tyco P/N 1-640445-4, 4 Position or equivalent
180414303Tyco P/N 1-640445-4, 4 Position or equivalent
180440362.5Tyco P/N 1-640445-4, 4 Position or equivalent
News Releases
TitleWeb Link
ETL-CERT-GTM41133-F UL 60950-1 2007_03_27 Ed 2 Rev 2011_12_19 + CAN_CSA C22.2 2007_03_27 Ed 2 R2012 Rev 2011_12_19 ETL-CERT-GTM41133-T2 -T3A UL 60950-1 2007_03_27 Ed 2 Rev 2011_12_19 + CAN_CSA C22.2 2007_03_27 Ed 2 R2012 Rev 2011_12_19
S-MARK-CERT-GTM41133-T2 -T3A -F EN60950-1_2006 + A11_2009 + A1_2010 + A12_2011
CB-CERT-GTM41133-T2 -T3A -F 3rd Edition 2xMOPP with RM IEC 60601-1_2005 and C1+C2 IEC 60601-1-11_2010 CB-REPORT-GTM41133-T2 -T3A -F 3rd Edition 2xMOPP with RM IEC 60601-1_2005 + Corr1(2006 )+ Corr 2(2007) and EN 60601-1_2006 + A11_2011
ETL-CERT and REPORT -GTM41133-T2 -T3A -F 2xMOPP ANSI_AAMI ES606001-1 2006-03-09-2005 + CAN_CSA-C22.2 60601-1 2008-02-01 and ANSI_AAMIHA60601-1-11
S-MARK-CERT-GTM41133-T2 -T3A -F EN60601-1_2006 + A11_2011 + EN60601-1-11_2010