Request Information Download PDF Configure Output Connector
GTM21097CCWWVV GTM21097CCWWVV
Information
Model NumberGTM21097CCWWVV
DescriptionGTM21097CCWWVV, Medical Power Supply, Desktop/External, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C14 AC Inlet Connector, Class I, Earth Ground, Output Rating: 50 Watts, 3.3-48V in 0.1V increments, Approvals: CB CE China RoHS Class I GOST-R IP42 PSE RoHS 2 Ukraine VCCI WEEE cRUus FCC Korea (12V Only)
Agency Documentshttp://www.globtek.info/certs/GTM21097/
CE EC-Declaration for Medicalhttp://globtek.force.com/models/ec_declaration?id=a0Oa000000LNLeBEAX
CE EC-Declaration for Industrial/Commercial/ITEContact GlobTek for more information
RoHS/RoHS3 Declarationhttp://www.globtek.com/pdf/rohs_cert/a0Oa000000LNLeBEAX
REACH Declarationhttp://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttp://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeDesktop/External
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor
CategoryMedical Power Supply
Input Voltage100-240V~, 50-60 Hz
I/P Amps (A)1.6A Max
Wattage (W)50
Vout Range (V)3.3-48
EfficiencyMeets/Exceeds for Medical
Ingress Protection
Size (mm)
Enclosure

                   User-added image
Indicator color: Green when charged



 
Rating Table
Model Number VoltageAmps (A)Watts (W) RFQ
GTM21097CC2003 3.3619.8 RFQ
GTM21097CC3005 5630 RFQ
GTM21097CC4509 9545 RFQ
GTM21097CC5012 124.1750.04 RFQ
GTM21097CC5015-1.3 13.71.621.92 RFQ
GTM21097CC5015-1.2 13.83.649.68 RFQ
GTM21097CC5015-0.3 14.72.130.87 RFQ
GTM21097CC-5015 153.349.5 RFQ
GTM21097CC5018 182.850.4 RFQ
GTM21097CC5024 242.150.4 RFQ
GTM21097CC5048-20.2 27.80.822.24 RFQ
GTM21097CC5048-18.3 29.70.823.76 RFQ
GTM21097CC5048 48148 RFQ
SpecificationsA) ELECTRICAL SPECIFICATIONS:
1. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac
2. Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz
3. Output Constant Current Regulation: +/- 5%
4. Output Voltage Regulation: +/- 5% measured at the output connector
5. Line Voltage Regulation: +/- 1% typical measures at full load
6. Output Ripple (Vp-p): 1% of output voltage typical measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with 10 uf electrolytic capacitor connected at the end of output connector at nominal line
7. Turn-On/Turn-Off Overshoot: 5% maximum, mS typical recovery time for 25% step load
8. Turn-On Delay: 1 S second typical
9. Hold-Up Time: 10mS typical @ nominal input voltage & full load
10. Inrush Current: 20A typical @ 115Vac input ; 30A typical @ 230Vac input
11. Switching Frequency: 100 KHz typical

B) PROTECTION
1. Over-Voltage: Voltage limited by crowbar unit will recover upon removal of fault
2. Short Circuit: Hiccup, unit will recover upon removal of fault
3. Input Protection: Input line & neutral fusing

C) SAFETY
1. Dielectric Withstand Voltage: 4242Vdc (2xMOOP) from primary to secondary
2. Earth Leakage Current: Did not exceed 5 mA in NORMAL CONDITION and 10 mA in SINGLE FAULT CONDITION
3. Touch Current: Did not exceed 100uA NC(Normal condition) 500uA SFC(single fault condition)
4. Earth continuity test:<0.1 Ohm or < 0.2 Ohm when with a non-detachable Power Supply cord, Class I Only
5. Earth Ground: Functional (Class I, (3) Pin Inlet)

D) OTHER:
1. MTBF: 200,000 hours @ 25°C ambient temperature
2. Operating Temperature: 0°C to 40°C ambient temperature
3. Humidity: 0% to 90% relative humidity
4. Storage Temperature: -10°C to 80°C
5. Ingress Protection: IPX0

E) ENCLOSURE
1. Upper Housing: High impact plastic, 94V0 polycarbonate, non-vented
2. Lower Housing: High impact plastic, 94V0 polycarbonate, non-vented
3. Size: 118*60*33 ± 0.5 mm
4. Green LED to indicate Power On

F) Voltage-Current Characteristic chart
User-added image

NOTES:
1. UNITS HAS ITS OUTPUT COMMON CONNECTED TO EARTH BY DEFAULT OR WITH OPTION OF
CAPACITOR INSERTED BETWEEN EARTH AND OUTPUT COMMON.
2. MINIMUM OUTPUT LOAD IS 100K OHMS.
Derating Curve
The derating curve is not applicable, since this is constant current model.
 
Qty (ea.)/Carton60
Individual Box/Gift Box Size (mm)147*100*33
Individual Box/Gift Box ColorWhite
Master Carton Size (mm)455 x 405 x 220
Gross Weight (kg)19.6
Label Width (mm)44.5
Label Height (mm)79.5
Input Configuration
DescriptionIEC 60320/C14 AC Inlet Connector, Class I, Earth GroundUser-added image
Mates with IEC 60320/C13 Plug

Optional Locking IEC60320 Receptable and cord option available on some models by request.:
User-added image

Standard International IEC 320/C13 Cordsets

Below are standard cordsets which are "not included" (unless stated above); these can be purchased separately or packaged with the power supply. Contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material.

 

Stock Power Supply Cords

Part Number/ Link

Country

Plug

Termination

Length (mm)

(Ft)

3 Conductors (Grounded) IEC 320/C13

3021457F701(R)

N. American

NEMA 5-15P

IEC 320/C13

2150

7

1191068F0701(R)

N. American

NEMA 5-15P Hospital

IEC 320/C13

2459

8

2194272M5701-T(R)

Argentina

IRAM 2073

IEC 320/C13

2500

8

5502022M5701A(R)

Australian

AS3112 / 3 PRONG

IEC 320/C13

2500

8

204B4272M5701(R)

Brazil

BRAZILIAN; WS-002

IEC 320/C13

2500

8

6023602M5701(R)

China

CCC GR2099

IEC 320/C13

2500

8

G8014272M5701(R)

Danish

AFSNIT SECTION 107-2-D1

IEC 320/C13

2500

8

23144272M5701-T(R)

Europe

CEE 7/7

IEC 320/C13

2500

8

20842710M701(R)

India

India IS 1293 (also known as IA16A3 or BS546)

IEC 320/C13

2500

8

377C4272M5701(R)

Israel

ISL 377C

IEC 320/C13

2500

8

23024272M5701(R)

Italy

CEI 23-16/VII

IEC 320/C13

2500

8

3003339F701(R) [3x1.25mm2]

3003068F2701-HK(R) [3 x 2.0mm2]

Japan

JIS 8303 / 3 PINS

IEC 320/C13

2500

8

2313K3432M5701(R)

Korea

KS C 8305

IEC 320/C13

2500

8

23144272M5701-T(R) [Same as Europe Above]

Russia

GOST 7396

IEC 320/C13

2500

8

2084272M5701(R)

S. Africa

S. African

IEC 320/C13

2500

8

23214272M5701(R)

Switzerland

SEV 1011 ( EL 203)

IEC 320/C13

2500

8

3003322M5701(R)

Taiwan

BSMI

IEC 320/C13

2500

8

PZ0800100-2M5BK13H(R

UK

BS 1363A

IEC 320/C13

2500

8

7055002M5701A(R)

International

IEC 320 C14-C13

IEC 320/C13

2500

8

Output Configuration
Common output connector options:
Click to add to your request.






L Type (Coaxial 5.5x2.5mm plug) C Type (Coaxial 5.5x2.1mm plug) K Type (Coaxial 3.5x1.3mm plug) LL Type (5.5x2.5mm Locking 760k type) CL Type (5.5x2.1mm Locking S761k type) Magnetic Connector





YL3 Type (KPPX-3P) YL4 Type (KPPX-4P) EJ1/2/3/4/5 (EIAJ RC-5320A type connectors) MSB Type (Micro USB) Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals
LogoDescription
User-added image60601-1 3rd Operating Instructions
No Logo ApplicableCB report IEC 60601-1: 2005 + CORR. 1 (2006) + CORR. 2 (2007) and or EN 60601-1:2006 3rd Edition including 2MOOP requirements
User-added image  CE Mark: tested to comply with EN 60601-1-2:2007 Medical electrical equipment Part 1-2: - Mark is on the label or Molded in the case
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
User-added image
Class I Earth Ground
User-added imagecRUus UL Recognized Component E341350 3rd Edition w-RM ANSI-AAMI ES60601-1 (2005 + C1:09 + A2:10) and CAN-CSA-C22.2 No. 60601-1 (2008)
User-added image
FCC PART 15 CLASS B
User-added image
 
GOST-R mark for Russia(Document: http://www.globtek.com/html/iso_certificates/GT_GOST-R.pdf). 03/15/2015. Due to lack of demand, GlobTek will not be renewing it's GOST certification. Please contact your sales engineer for pricing on EAC.
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
IP42Ingress Protection: IP42 to IEC60529:2001 Protection against granular foreign bodies - Protected against direct sprays up to 15o from the vertical Optional
User-added image
Korea KET KC Mark GTM21097-5012 HU10040-7022B (12V Only)
User-added imageJAPAN TUV Rheinland-PSE GlobTek Inc to J60950-1(H26) , J55022(H22),J3000(H25).Please follow the procedure listed in the following link for proper import to Japan: http://en.globtek.com/importing-to-japan.php.
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added image
Serial Number Information
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products
SKUVolts OutCurrent Out (Amps)Connector
14417113.71.6Female Barrel 5.5*2.5*14.5mm, Locking or Equal
21854013.71.6Female Barrel 5.5 * 2.5 * 10mm with internal Spring Clip and Locking Notch or Equal
13652813.83.6Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
12932614.72.1SWITCHCRAFT SLIM LINE, PART # SL403FX
12417827.80.8Female Barrel 5.5*2.1*11mm WITH internal Spring Clip and Locking Notch or Equal
50344227.80.8Female Barrel 5.5*2.1*11mm WITH internal Spring Clip and Locking Notch or Equal
18271527.80.8Female Barrel 5.5*2.1*11mm WITH internal Spring Clip and Locking Notch or Equal
18923429.70.8Female Barrel 5.5*2.1*11mm WITH internal Spring Clip and Locking Notch or Equal

Request Info