GTM91099-60VV-T2 Wall Plug-in+Desktop Combination Medical/ICT/ITE/Household use Power Supply Datasheet

GTM91099-60VV-T2
GTM91099-60VV-T2, Medical/ICT/ITE/Household use Power Supply,  60601-1-4th Ed. , Wall Plug-in+Desktop Combination, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C8 AC Inlet connector, Output Rating: 60 Watts, Power rating with convection cooling (W) , 5-48V in 0.1V increments, Approvals: ETL; Korea (16V, 18V, 19V, 20V, 24V Only; UKCA; India BIS  5V, 12V, 13.8V, 15V, 18V, 19V, 20V, 24V, 36V, 48V; Korea (9.1V,10V,11V,12V, 13V,13.8V,14V,15V Only); CB 62368; Conforms to 62368-1; ETL 62368; IEC 61558-1; 61558-1; South Africa; CE; Ukraine; Level V; China RoHS; WEEE; CE; EC; RoHS; VCCI; IEC 60335; Fuse 60335; LPS 60950; Book 60601; Double Insulation; CB 60601-1 2MOPP; RCM; CE; CCC; cRUus; cULus; CB 60950; CB EN/IEC 60335-1; Peru; IRAM; Taiwan BSMI (16V only); SGS (Brazil); Singapore (16V only);Malaysia; Colombia; NOM (16V only); IEC/EN60601-1; CE; EAC; S-Mark IEC/EN 60601-1 60950; ETL; CB 61158; South Africa; South Africa; PSE; PSE; PSE; FCC; IP42; 2MOPP; CB 60601-1; GTM91099-60VV-T2, Medical/ICT/ITE/Household use Power Supply,  60601-1-4th Ed. , Wall Plug-in+Desktop Combination, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C8 AC Inlet connector, Output Rating: 60 Watts, Power rating with convection cooling (W) , 5-48V in 0.1V increments, Approvals: ETL; Korea (16V, 18V, 19V, 20V, 24V Only; UKCA; India BIS  5V, 12V, 13.8V, 15V, 18V, 19V, 20V, 24V, 36V, 48V; Korea (9.1V,10V,11V,12V, 13V,13.8V,14V,15V Only); CB 62368; Conforms to 62368-1; ETL 62368; IEC 61558-1; 61558-1; South Africa; CE; Ukraine; Level V; China RoHS; WEEE; CE; EC; RoHS; VCCI; IEC 60335; Fuse 60335; LPS 60950; Book 60601; Double Insulation; CB 60601-1 2MOPP; RCM; CE; CCC; cRUus; cULus; CB 60950; CB EN/IEC 60335-1; Peru; IRAM; Taiwan BSMI (16V only); SGS (Brazil); Singapore (16V only);Malaysia; Colombia; NOM (16V only); IEC/EN60601-1; CE; EAC; S-Mark IEC/EN 60601-1 60950; ETL; CB 61158; South Africa; South Africa; PSE; PSE; PSE; FCC; IP42; 2MOPP; CB 60601-1;GTM91099-60VV-T2, Medical/ICT/ITE/Household use Power Supply, 60601-1-4th Ed. , Wall Plug-in+Desktop Combination, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C8 AC Inlet connector, Output Rating: 60 Watts, Power rating with convection cooling (W) , 5-48V in 0.1V increments, Approvals: ETL; Korea (16V, 18V, 19V, 20V, 24V Only; UKCA; India BIS 5V, 12V, 13.8V, 15V, 18V, 19V, 20V, 24V, 36V, 48V; Korea (9.1V,10V,11V,12V, 13V,13.8V,14V,15V Only); CB 62368; Conforms to 62368-1; ETL 62368; IEC 61558-1; 61558-1; South Africa; CE; Ukraine; Level V; China RoHS; WEEE; CE; EC; RoHS; VCCI; IEC 60335; Fuse 60335; LPS 60950; Book 60601; Double Insulation; CB 60601-1 2MOPP; RCM; CE; CCC; cRUus; cULus; CB 60950; CB EN/IEC 60335-1; Peru; IRAM; Taiwan BSMI (16V only); SGS (Brazil); Singapore (16V only);Malaysia; Colombia; NOM (16V only); IEC/EN60601-1; CE; EAC; S-Mark IEC/EN 60601-1 60950; ETL; CB 61158; South Africa; South Africa; PSE; PSE; PSE; FCC; IP42; 2MOPP; CB 60601-1; GTM91099-60VV-T2, Medical/ICT/ITE/Household use Power Supply, 60601-1-4th Ed. , Wall Plug-in+Desktop Combination, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C8 AC Inlet connector, Output Rating: 60 Watts, Power rating with convection cooling (W) , 5-48V in 0.1V increments, Approvals: ETL; Korea (16V, 18V, 19V, 20V, 24V Only; UKCA; India BIS 5V, 12V, 13.8V, 15V, 18V, 19V, 20V, 24V, 36V, 48V; Korea (9.1V,10V,11V,12V, 13V,13.8V,14V,15V Only); CB 62368; Conforms to 62368-1; ETL 62368; IEC 61558-1; 61558-1; South Africa; CE; Ukraine; Level V; China RoHS; WEEE; CE; EC; RoHS; VCCI; IEC 60335; Fuse 60335; LPS 60950; Book 60601; Double Insulation; CB 60601-1 2MOPP; RCM; CE; CCC; cRUus; cULus; CB 60950; CB EN/IEC 60335-1; Peru; IRAM; Taiwan BSMI (16V only); SGS (Brazil); Singapore (16V only);Malaysia; Colombia; NOM (16V only); IEC/EN60601-1; CE; EAC; S-Mark IEC/EN 60601-1 60950; ETL; CB 61158; South Africa; South Africa; PSE; PSE; PSE; FCC; IP42; 2MOPP; CB 60601-1;
Information
Model NumberGTM91099-60VV-T2
Agency Documentshttp://www.globtek.info/certs/GTM91099/
CE EC-Declaration for Medicalhttps://globtek.secure.force.com/models/ec_declaration?id=a0O30000007P7ZeEAK
CE EC-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ec_declaration?id=a0O30000007P7ZeEAK
CE EC-Declaration for Householdhttps://globtek.secure.force.com/models/ec_declaration?id=a0O30000007P7ZeEAK
UKCA-Declaration for Medicalhttps://globtek.secure.force.com/models/ukca_declaration?id=a0O30000007P7ZeEAK
UKCA-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ukca_declaration?id=a0O30000007P7ZeEAK
UKCA-Declaration for Householdhttps://globtek.secure.force.com/models/ukca_declaration?id=a0O30000007P7ZeEAK
Morocco SDoC Declarationhttps://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0O30000007P7ZeEAK
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0O30000007P7ZeEAK
Prop 65 Statementhttps://en.globtek.com/prop-65-statement.pdf
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeWall Plug-in+Desktop Combination
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor
CategoryMedical/ICT/ITE/Household use Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)1.5 A
Max Output Power Rating (W)60
Output Voltage Range (V)5-48
EfficiencyV
Ingress ProtectionIP42
Size (mm)117.53*53.47*36.6
EnclosureUser-added image
                         Units shipped without an installed input plug have a "desktop insert" installed.

User-added image
                                
Rating Table
Model Number (Final ordering #/Part No to be defined)Voltage (V)Current (A)Power (W)RFQ
GTM91099-3009-1.0-T2*83.7530
GTM91099-6515-2.4-T2*12.65.1564.89
GTM91099-2509-4.0-T2*5525
GTM91099-6019-T2*193.1559.85
GTM91099-3009-4.0-T2*5630
GTM91099-4509-T2*9545
GTM91099-6015-3.0-T2*12560
GTM91099-6015-T2*15460
GTM91099-6024-T2*242.560
GTM91099-6048-T2*481.2560
GTM91099-3009-4.0-T2*5630
GTM91099-4509-T2*9545
GTM91099-6015-T2*15460
GTM91099-6024-T2*242.560
GTM91099-6048-T2*481.2560
GTM91099-3009-3.0-T2*6530
GTM91099-3009-2.5-T2*6.54.629.9
GTM91099-6024-8.0-T2*163.7560
GTM91099-4048-T2*480.83339.98
GTM91099-6024-4.0-T2*20360
GTM91099-6036-T2*361.6659.76
GTM91099-6048-18.0-T2*361.6659.76
GTM91099-6048-12.0-T2*361.6659.76
GTM91099-6015-3.0-T2*12560
GTM91099-6024-6.0-T2*183.3359.94
GTM91099-6015-1.2-T2*13.84.3459.89
GTM91099-3024-4.0-T2*201.530
* (Final ordering #/Part No to be defined)
Specifications
A) ELECTRICAL SPECIFICATIONS:
01. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac
02. Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz
03. Output Regulation: +/- 5% nominal output voltage measured at the output connector at nominal line
04. Line Voltage Regulation: +/- 2% max at full load
05. Output Ripple (Vp-p): +/-1% or 150mV whichever is greather at nominal output voltage. Measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with 10 uf electrolytic capacitor connected at the end of the output connector.
06. Turn-ON/OFF Overshoot: 5% max, 500uS max recovery time for 25% to 50% step load
07. Turn-ON Delay: 2 Seconds, maximum @ full load, nominal line
08. Hold-Up Time: 8 mS at nominal input and full load
09. Inrush Current: 40A max at cold start 120 VAC, 60A max cold start 230VAC
10. Switching Frequency: 100 KHz typical

B) PROTECTION
1. Over-Voltage: Protected, Hiccup with auto recovery
2. Short Circuit: Protected, Hiccup with auto recovery
3. Over-load: Protected, Hiccup with auto recovery
4. Input Protection: Input line and neutral fusing
5. Means of Patient Protection: (2 x MOPP)

C) SAFETY
01. Dielectric Withstand Voltage: 5656Vdc from primary to secondary
02. Touch Current: Maximum allowed values: 100uA NC(Normal condition) 500uA SFC(single fault condition)
03. Means of Protection: 2 x MOPP
04. Primary to Secondary Bridging Capacitor: (2) * Y1 type capacitors in series

D) OTHER:
1. MTBF: 200,000 Hours @ 25°C ambient temperature
2. Operating Temperature: 0°C to 40°C ambient temperature
3. Humidity: 0% to 90% relative humidity
4. Storage Temperature: -10°C to 80°C
5. Cooling: Convection

E) ENCLOSURE
1. Housing: High impact plastic, 94V0 polycarbonate, non-vented
2. Size: 117.53*53.47*36.6 mm +/- 1.0
3. Markings: Label and/or Pad Printed and/or Molded into Case
4. LED: Standard Green color to indicate power on
Derating CurveUser-added image
      Note:
       @ 15W UL certified to +70C for GTM91099-3009-4.0 only
Qty (ea.)/Carton60
Individual Box/Gift Box Size (mm)142*62*60
Individual Box/Gift Box ColorWhite
Master Carton Size (mm)442 x 330 x 275
Gross Weight (kg)15.2
Label Width (mm)44.5
Label Height (mm)49.5
Input Configuration
DescriptionIEC 60320/C8 AC Inlet connectorBlade Insertion Instructions
R-Blade Style Instruction Video

User-added image
Mates with IEC 60320/C8 Plug

This series of Interchangeable Blade products may be used with Proprietary Interchangeable Blades as described below or with standard international power cords.
 
Optional INPUT BLADES: R-Socket: below are available blades configurations which are "not included" (unless stated above); may be purchased separately, packaged with power supply, or as a separate "R-KIT" if specified 
 
#Part NumberMain Country/RegionPlugIECEE Type
1R-NA-2(R) North America, JapanNema 1-15PType A
2R-SAA-2(R) Australia/New Zealand AS/NZ 3112 Type I
3R-UK-2(R) United Kingdom/IrelandUK, Hong Kong, Singapore, Gulf StatesType G
4R-EU-2(R)EuropeCEE 7/16Type C
5R-CN-2(R)ChinaGB 2099 Type A
6461-03030003(R)N/AR-DI(R) Desktop Insert for use with a cordN/A
7R-KIT-2(R)prepackaged kit1,2,3,4 aboveN/A
8R-KIT-2-INTL(R)prepackaged kit2,3,4 aboveN/A

User-added image

Standard Cordsets
Below are standard cordsets which are "not included" (unless stated above); these may be purchased separately or packaged with the power supply. Contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material.

Standard International IEC 320/C7 Cordsets
  
Part NumberCountryPlugConnectorLength (mm)Length (feet)
2094112M703(R)Argentina (Type I)IRAM 2063IEC 320/C720007
5014112M703A(R)Australian (Type I)AS 3112IEC 320/C720007
207B4111M8703(R)Brazil (Type N)NBR14136IEC 320/C718006
4533501M8703(R)China (Type A)GB 2099.1IEC 320/C718306
2074112M703A(R)European (Type C)CEE 7/16IEC 320/C720007
2084111M8703(R)South Africa (Type M)BS 546IEC 320/C718006
2084111M8703B(R)India (Type D)ISI:1293IEC 320/C718006
2714111M8703A(R)India (Type C)ISI:1293IEC 320/C718006
451J3401M8703(R)Japan (Type A)JIS 8303IEC 320/C718306
2044112M703A(R)Korea (Type C)KS C8305IEC 320/C720007
4511116F703A(R)N. American (Type A)NEMA 1-15PIEC 320/C718306
4033401M8703A(R)Taiwan (Type A)CNS690IEC 320/C718306
6104112M703A(R)UK, Hong Kong, Singapore, Gulf States (Type G)BS1363IEC 320/C720007
Output Configuration
Common output connector options:
Click to add to your request.
L Type (Coaxial 5.5x2.5mm plug)
C Type (Coaxial 5.5x2.1mm plug)
K Type (Coaxial 3.5x1.3mm plug)
LL Type (5.5x2.5mm Locking 760k type)
CL Type (5.5x2.1mm Locking S761k type)
Magnetic Connector
L Type (Coaxial 5.5x2.5mm plug)C Type (Coaxial 5.5x2.1mm plug)K Type (Coaxial 3.5x1.3mm plug)LL Type (5.5x2.5mm Locking 760k type)CL Type (5.5x2.1mm Locking S761k type)Magnetic Connector
YL3 Type (KPPX-3P)
YL4 Type (KPPX-4P)
EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)
MSB Type (Micro USB)
Custom design
YL3 Type (KPPX-3P)YL4 Type (KPPX-4P)EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)MSB Type (Micro USB)Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals

Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.

Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.

LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
User-added imageInformation Technology Equipment Safety Part 1: General Requirements (UL 60950-1 Issued: 2007/03/27 Ed: 2 Rev: 2014/10/14)
User-added imageKorea HU10499-18034A GTM91099-6024-8.0-T2 (16V, 18V, 19V, 20V, 24V Only)
User-added image
 
UKCA Certification
User-added image
 
INDIA BIS (GTM91099-T2) 5V, 12V, 13.8V, 15V, 18V, 19V, 20V, 24V, 36V, 48V only
User-added imageKorea HU10499-21045A GTM91099-6015-T2(A) (9.1V,10V,11V,12V, 13V,13.8V,14V,15V)

No Logo Applicable

CB for IEC 62368-1:2014 (Second Edition)
Conforms to UL STD. 62368-1
Certified to CSA STD C22.2 NO.62368-1
Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1
User-added imageAudio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [UL 62368-1:2014 Ed.2] Audio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [CSA C22.2#62368-1:2014 Ed.2]
User-added imageTransformer Symbol IEC 61558-1 SMPS Switch Mode Power supply
User-added imageTransformer Symbol IEC 61558-1 SMPS Short-Circuit –Proof Safety Isolating Transformer
 No LogoSouth Africa approval to SANS IEC 60950
User-added image  CE Certification Class II CE Mark: tested to comply with EN55022:2006/A1:2007 Class B, EN610003-2, EN610003-3 including EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6N EN61000-4-11; EMI: Complies with EN55011 CLASS B and FCC Part 15 B
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
 User-added image

Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
User-added image  CE Mark: tested to comply with EN 60601-1-2:2015 Medical electrical equipment Part 1-2: - Mark is on the label or Molded in the case
User-added image
Serial Number Information
No LogoEC-Conformity Declaration: http://www.globtek.com/html/iso_certificates/EC-DECLARATION.pdf, REACH 144 SVHC: http://www.globtek.com/html/iso_certificates/Reach144.pdf
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
User-added image
IEC/EN60335-1 Up to 36 volts
User-added imageBook 60335 up to 36 Volts
LPSLimited Power Source 60950
User-added image60601-1 3rd Operating Instructions
User-added image
No Logo ApplicableCB report IEC 60601-1: 2005 + CORR. 1 (2006) + CORR. 2 (2007) and or EN 60601-1:2006 3rd Edition 2xMOPP
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
User-added imageRCM N136; Australia and New Zealand Regulatory Compliance, Mark (http://rcm.standards.org.au/rcmfaq/rcmfaq.htm
User-added image  CE Mark: tested to comply with Additional EN610006-1:2007, EN610006-2:2005 EN61000-6-3:2007+A1:2011 EN61000-6-4:2007+A1:2011
User-added image
 
CCC to GB4943.1-2011 GB9254-2008 GB17625.1-2012
User-added imagecRUus UL Recognized Component E172861 3rd Edition w-RM ANSI-AAMI ES60601-1 (2005 + C1:09 + A2:10) and CAN-CSA-C22.2 No. 60601-1 (2008)
User-added imageUL 60950-1, 2nd Edition, 2011-12-19 (Information Technology Equipment - Safety - Part 1: General Requirements) CSA C22.2 No. 60950-1-07, 2nd Edition, 2011-12 (Information Technology Equipment - Safety - Part 1: General Requirements)
No Logo CB Certificate IEC 60950-1:2005 (2nd Edition), Am 1: 2009, CB report IEC 60950-1:2005 (2nd Edition), Am 1: 2009 and EN 60950-1:2006 + Am 1:2010 + Am 11:2009 + Am 12:2011

No Logo Applicable

CB to 60335-1 5th Edition (Safety of Household and Similar Electrical Appliances, Part 1: General Requirements) CB Report/ Certificate IEC 60335-1:2010 Up to 36 volts only
No Logo Peru MTC GTM91099-T2 No logo
User-added image
PRECAUCION: PARA USO EN EQUIPOS ELECTRONICOS SOLAMENTE
 
IRAM certificate DC-E-G71-001.7 to IEC 60950 + A1:2009
 User-added image
 R32282
RoHS (Pb)
 
BSMI Taiwan GTM91099-6024-8.0-T2 (16V only); CNS143361-1 (99) CNS13438 (95) http://www.bsmi.gov.tw/wSite/ct?xItem=4072&ctNode=816&mp=2
User-added image
FONTE DE ALIMENTAÇÃO DE ITE
SGS (Brazil) to IEC 60950-1_2005 + A1_2009 +A2_2013 (5 - 48 Volts)
User-added imageSingapore GTM91099-6024-8.0-T2 ICE 60950-1:2005 + 2009 +A2:2013 (16V only)
No Logo Malaysia ST Release Letter GTM91099T2 -T3A IEC60950-1(Ed.2): 2005 + A1:2009 No logo
No Logo Colombia GTM91099-T2 No logo
User-added image
 
NOM (Mexico) to NOM-001-SCFI-1993 GTM91099-6024-8.0-T2 for 16V only
User-added image
IEC/EN60601-1
User-added image  CE Certification CE Mark: tested to comply with EN 55032.2012+AC.2013 EN 61000-3-2.2014 EN 61000-3-3.2013 EN 60601-1-2.2015 EN 55024.2010
User-added image  Certification # TC RU AR46.B.75423 Custom Union of Russia, Belarus and Kazakhstan
User-added imageSemko S-Mark-Cert-EN60601-1 and EN60950-1
User-added imageMedical Electrical Equipment – Part 1: General Requirement for Basic safety Essential Performance (AAMI ES60601-1:2005+A1) Medical Electrical Equipment – Part 1: General Requirement for Basic safety Essential Performance (CSA C22 2#60601-1:2014 Ed.3)

No Logo Applicable

IEC 61558-1:2005+A1, IEC 61558-2-16:2009+A1
 No Logo12
 No Logo12
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50313287, to J60950-1(H26) , J55022(H22),J3000(H25)[DC15?30V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[15V or less]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50313287, to J60950-1(H26) , J55022(H22),J3000(H25)[DC30?60V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageFCC PART 15B Report STR14078169E-3
IP42Ingress Protection: ?IP42 to IEC60529:2001 Protection against granular foreign bodies - Protected against direct sprays up to 15o from the vertical Optional
2MOPP2 x MOPP (Means of Patient Protection) marked with 2MOPP near model name
No Logo ApplicableIEC 60601-1: 2005 + C1 + C2 + A1
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample Request
239671416.03.75
143856815.04.0
135457512.05.0
132168912.05.0
125910712.05.0
17696124.02.5
94935524.02.5
104764513.84.34
14653912.05.0
5852840.00.0
62895715.04.0
5132618.03.75
17078013.84.34
52944112.05.0
39225524.02.5
23346512.05.0
22993512.05.0
2329575.06.0
23860224.02.5
25476812.05.0
14974720.01.5
20534748.01.25
19975636.01.66
21379812.05.0
22332813.84.34
22628118.03.33
2343150.00.0
18731224.02.5
18426212.05.0
18118915.04.0
18087812.05.0
1775010.00.0
18074548.00.833
19891620.03.0
16815015.04.0
17100812.05.0
1807555.06.0
17507716.03.75
16971412.65.15
16885412.05.0
16872015.04.0
17285818.03.33
17491512.05.0
17322624.02.5
17287118.03.33
16715412.05.0
16852612.05.0
13581712.05.0
19614712.05.0
32469524.02.5
26449312.05.0
17762012.05.0
16863712.05.0
36157218.03.33
38473324.02.5
34495612.05.0
35324412.05.0
2699925.05.0
26441224.02.5
26307513.84.34
2642570.00.0
24093924.02.5
22768312.05.0
2263035.06.0
21380212.05.0
22326012.05.0
22117524.02.5
21381248.01.25
19812912.05.0
19997512.05.0
1993825.06.0
18153924.02.5
19983712.05.0
19984024.02.5
19856912.05.0
17695724.02.5
19376348.01.25
19468112.03.0
19695412.05.0
18995215.04.0
17484412.05.0
18033612.05.0
18379524.02.5
17862712.05.0
17941212.05.0
17941324.02.5
17950515.04.0
17076024.02.5
17522215.04.0
17515824.02.5
17251624.02.5
17108624.02.5
16871519.03.16
16981224.02.5
16715612.05.0
1669970.00.0
1671870.00.0
24887619.03.15
12744724.00.0
1463850.00.0
12743924.02.5
11076424.02.5
14654224.02.5
10162912.00.0
11075712.00.0
11076524.00.0
13582048.00.0
1180400.03.5
11791415.03.5
165705115.04.0
134336612.05.0
143465712.05.0
202899948.01.25
181312
2375826.05.0
23842513.84.3
24376912.05.0
2441945.06.0
2441955.06.0
26308036.01.7
26425415.04.0
179059
1798676.54.5
17990318.03.3
18037112.05.0
18058224.02.5
1809026.54.6
18104124.02.5
18108924.02.5
181309
181310
181365
18367424.02.5
18426612.05.0
18432424.02.5
18437219.03.2
18437612.05.0
18437724.02.5
18598212.05.0
18605115.04.0
1901835.06.0
19115848.00.4
19141024.02.5
20415824.02.5
19972424.02.5
19976512.05.0
22356518.03.3
22384424.02.5
2263045.06.0
2289795.06.0
23572112.05.0
199795
11076724.02.1
14972524.0
15028412.0
16383924.0
16453124.0
16570412.0
16589124.0
166281
1663485.0
16701724.0
16715512.05.0
16716024.0
16822224.02.5
16864618.0
168661
16866224.02.5
16984648.01.3
17092337.01.3
17092919.03.2
17138424.02.5
1717005.06.0
17200424.02.5
17325518.03.3
17493612.05.0
17798624.02.5
1959185.06.0
19614212.05.0
19767048.01.3
19836724.02.5
61757812.05.0
5852828.03.8
What is an IEC 60601-1 medical grade rated power supply AC adapter?

An IEC 60601-1-2 medical grade rated power supply AC adapter converts input line voltage from the wall to a lower voltage, typically DC, which is used to operate and end use piece of medical equipment. IEC 60601-1-2 medical grade power supply AC adapters are typically housed in a plastic enclosure and are available with both 2 and 3 prong input options. power supplies are also available as open frame for use inside of medical equipment. These AC to DC converters are designed in accordance with international medical standards and provide for compliance with certain aspects of them which differs from generic information and communication technology equipment power supplies.

Why is my medical grade IEC 60601-1 power supply certified to IEC 60601-1 3rd Edition while the latest standard is IEC 60601-1 4th Edition?
IEC 60601-1 has different sections in specifications for safety and EMI/EMC. The latest revision of the safety portion of  IEC 60601-1 is 3rd Edition while for EMI/EMC the latest revision is 60601-1-2, 4th Ed. 

What is the effective date of 60601-1-2, 4th Ed?
60601-1-2, 4th Ed. was effective on December 31, 2018.

What's the difference between an IEC 60950-1 and IEC 60601-1 medical grade rated power supply?

IEC 60950-1 and IEC 60601-1-2 power supplies are both AC to DC converters and may be either internal or external but are designed to different specifications to match the end system specifications. While the basic performance behaviors are similar such as input and output voltages and mechanical configurations, there are many differences as well. Some of the key differences are that medical IEC 60601 medical grade AC to DC adapters are able to withstand a higher dielectric withstand voltage and must have lower leakage current.  There are many other differences and also considerations to consider depending on the end use application.  

What MOOP and MOPP?
Medical devices must incorporate one or more Means of Protection (MOPs) to isolate patients and operators from the risks of electrocution. A Means of Protection (MOPs)  can be safety insulation, a protective earth, a defined creepage distance, or an air gap or other protective impedance. These can be used in various combinations. IEC 60601-1 3rd edition differentiates between the risk to patients and the risk to operators. A MOP can therefore be classified as Means of Patient Protection (MOPP) or a Means of Operator Protection (MOOP). The main difference between one MOOP and one MOPP is primarily one of permissible creepage distance. Both requirements are satisfied using Basic insulation. To achieve 2 x MOPP qualification the isolation test is particularly demanding at 4000 Vac and the creepage distance of 8mm is twice that required for one MOPP. 

What is a BF and CF rated an IEC 60601-1-2 medical grade rated power supply AC adapter and what is the difference?

Medical grade power supplies and AC to DC adapters are categorized into one of three applied parts types: body type (B), body floating type (BF), and cardiac floating type (CF). These applied parts require specific attributes such as isolation voltage, creepage and leakage current. Floating refers to an ungrounded power supply, Class II, that is not referenced to another output and is fully isolated. Type B refers to devices that operate within the patient's vicinity, as described in IEC 60601-1 as six feet around a patient's chair or bed and do not touch the patient electronically and are grounded. These devices include operating room lighting, hospital carts and beds, automated dispensers of medication and supplies, and diagnostic equipment like x-ray machines. Type BF devices deliver electrical energy signals to or from the patient such as electrosurgical devices, endoscopes, and electrical vital sign monitors like thermometers. Type CF devices are similar to BF, except they supply power to devices connected to the heart, such as a defibrillator, external pacemaker or intracardiac ECG electrodes and Type CF requires a higher degree of protection against electrical shock than BF types.  
 

What is a hybrid wall Plug-in/desktop AC-DC Adapter?

Hybrid wall Plug-in/desktop AC-DC Adapters are also known as AC Adaptors or AC-DC converters and are a type of external power supply. These devices are considered a hybrid because they can be used as a standard desktop power supply utilizing an IEC 60320 power cord or using the proprietary input blade system can be used as a wall plug-in and plug directly into the wall without a cord. Some electrical appliances require power but lack the internal components to derive the required voltage and power from mains power. This is where an AC adapter is used to convert the AC current into DC voltage

What is IEC 60335-1?

The International Standard 60335-1 covers the safety of electrical appliances for household and similar purposes with rated voltage not more than 250 V for single-phase appliances and 480 V for other appliances.

Why is an IEC 60335-1 rated power supply or AC adapter necessary?

Applications used in the household environment are mandated to use and IEC 60335-1 certified power supply or AC to DC converter. These unique power supplies provide for specific compliance necessary for household use appliances.

What is the The Unique Device Identification (UDI) for my GlobTek medical grade power supply?

The Unique Device Identification (UDI) as required by the Food and Drug Administration Amendments Act of 2007 and EU Medical Device Regulation (MDR) is required for registered medical devices. While GlobTek medical grade power supplies carry full medical certifications they're actually not considered medical devices themselves but a component of such. And therefore do not have registration with the Food and Drug Administration Amendments Act of 2007 and EU Medical Device Regulation (MDR) and therefore so not carry a The Unique Device Identification (UDI).

How Does an AC-DC Wall Adapter Work?

The AC to DC adapter or external power supply consists of a power supply which is enclosed in a housing similar to an AC plug, hence the term plug type, wall plug in, plug-in or plugtop power adapter. The power supply is plugged into the mains socket and the AC Voltage is then converted by the AC to DC adapter power supply into a DC voltage that is fed into the appliance via the output cable connection.

Request Info
Call
Email
💬
Text
💁
Chat
?
Request a Quote