Request Information Download PDF Configure Output Connector
GTM21097CC-WWVV-T2 GTM21097CC-WWVV-T2
Information
Model NumberGTM21097CC-WWVV-T2
DescriptionGTM21097CC-WWVV-T2, Medical Power Supply, Desktop/External, Regulated Switchmode AC-DC, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C8 AC Inlet connector, Class II, Non-Earth Ground (aka "Figure-8"), Output Rating: 50 Watts, 3.3-48V in 0.1V increments, Approvals: CB CE China RoHS Double Insulation cUR FCC GOST-R IP42 Korea (12V Only) PSE RoHS 2 SIQ Ukraine VCCI WEEE
Agency Documentshttp://www.globtek.info/certs/GTM21097/
CE EC-Declaration for Medicalhttp://globtek.force.com/models/ec_declaration?id=a0Oa000000MFCYkEAP
CE EC-Declaration for Industrial/Commercial/ITEContact GlobTek for more information
RoHS/RoHS2 Declarationhttp://www.globtek.com/pdf/rohs_cert/a0Oa000000MFCYkEAP
REACH Declarationhttp://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttp://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeDesktop/External
TechnologyRegulated Switchmode AC-DC
CategoryMedical Power Supply
Input Voltage100-240V~, 50-60 Hz
I/P Amps (A)1.6A Max
Wattage (W)50
Vout Range (V)3.3-48
EfficiencyMeets/Exceeds for Medical
Ingress Protection
Size (mm)118*60*33±0.5 mm
Enclosure


User-added image
INDICATOR:
GREEN LED: CHARGED
AMBER LED: CHARGING










 
Rating Table
Model Number VoltageAmps (A)Watts (W) RFQ
GTM21097CC-5048-20.2-T2 27.80.822.24 RFQ
SpecificationsA) ELECTRICAL SPECIFICATIONS:
1. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac
2. Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz
3. Output current range: 0 to XXA, constant current set to XXA
4. Output Regulation: +/- 5% measured at the output connector
5. Line Voltage Regulation: +/- 1% typical measures at full load
6. Output Ripple (Vp-p): 1% of output voltage typical measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with 10 uf electrolytic capacitor connected at the end of output connector at nominal line
7. Turn-On/Turn-Off Overshoot: 5% maximum, mS typical recovery time for 25% step load
8. Turn-On Delay: 1 S second typical
9. Hold-Up Time: 10mS typical @ nominal input voltage & full load
10. Inrush Current: 20A typical @ 115Vac input ; 30A typical @ 230Vac input
11. Switching Frequency: 100 KHz typical

B) PROTECTION
1. Over-Voltage: Voltage limited by crowbar unit will recover upon removal of fault
2. Short Circuit: Hiccup, unit will recover upon removal of fault
3. Input Protection: Input line & neutral fusing

C) SAFETY
1. Dielectric Withstand Voltage: 4242Vdc (2xMOOP) from primary to secondary
2. Earth Leakage Current: Did not exceed 5 mA in NORMAL CONDITION and 10 mA in SINGLE FAULT CONDITION
3. Touch Current: Did not exceed 100uA NC(Normal condition) 500uA SFC(single fault condition)

D) OTHER:
1. MTBF: 200,000 hours @ 25°C ambient temperature
2. Operating Temperature: 0°C to 40°C ambient temperature
3. Humidity: 0% to 90% relative humidity
4. Storage Temperature: -10°C to 80°C
5. Ingress Protection: IPX0

E) ENCLOSURE
1. Upper Housing: High impact plastic, 94V0 polycarbonate, non-vented
2. Lower Housing: High impact plastic, 94V0 polycarbonate, non-vented
3. Size: 118*60*33 ± 0.5 mm
4. Green LED to indicate Power On
Derating Curve




User-added image

FOR PRECISE OPERATION, THE OUTPUT VOLTAGE DURING CONSTANT
CURRENT MODE SHOULD BE HELD ABOVE 5V.









 
Qty (ea.)/Carton60
Individual Box/Gift Box Size (mm)147*100*33
Individual Box/Gift Box ColorWhite
Master Carton Size (mm)455 x 405 x 220
Gross Weight (kg)19.6
Label Width (mm)44.5
Label Height (mm)79.5
Input Configuration
DescriptionIEC 60320/C8 AC Inlet connector, Class II, Non-Earth Ground (aka "Figure-8")User-added image

Mates with IEC 60320/C7 Plug

Standard International IEC 320/C7 Cordsets

Below are standard cordsets which are "not included" (unless stated above); these may be purchased separately or packaged with the power supply. Please contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material.

 
Conductors (No Ground) IEC 320/C7 (Figure "8")
Part NoCountryEnd AEnd BLength
4511116F703A(R)N. AmericanNEMA 1-15PIEC 320/C71830
5014112M703A(R)AustralianAS 3112IEC 320/C72000
4533501M8703(R)ChinaGB 2099.1IEC 320/C71830
2074112M703A(R)EuropeanCEE 7/16IEC 320/C72000
451J3401M8703(R)JapanJIS 8303IEC 320/C71830
2044112M703A(R)KoreaKS C 8305IEC 320/C72000
4033401M8703A(R)TaiwanCNS 10917IEC 320/C71800
6104112M703A(R)UKBS1363IEC 320/C72000
Output Configuration
Common output connector options:
Click to add to your request.






L Type (Coaxial 5.5x2.5mm plug) C Type (Coaxial 5.5x2.1mm plug) K Type (Coaxial 3.5x1.3mm plug) LL Type (5.5x2.5mm Locking 760k type) CL Type (5.5x2.1mm Locking S761k type) Magnetic Connector





YL3 Type (KPPX-3P) YL4 Type (KPPX-4P) EJ1/2/3/4/5 (EIAJ RC-5320A type connectors) MSB Type (Micro USB) Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals
LogoDescription
User-added image60601-1 3rd Operating Instructions
No Logo ApplicableCB report IEC 60601-1: 2005 + CORR. 1 (2006) + CORR. 2 (2007) and or EN 60601-1:2006 3rd Edition including 2MOOP requirements
User-added image  CE Mark: tested to comply with EN61000-3-2, EN61000-3-3 and EN50082-1, including EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61001-1-2-2007 EMI: Complies with EN55011 CLASS B and FCC Part 15 B
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
User-added imageUR 60601-1, 3rd Edition, CAN/CSA-C22.2 No. 601.1-1
User-added image

Double Insulation - Mark is on the label or Molded in the case
User-added image
FCC PART 15 CLASS B
User-added image
 
GOST-R mark for Russia(Document: http://www.globtek.com/html/iso_certificates/GT_GOST-R.pdf). 03/15/2015. Due to lack of demand, GlobTek will not be renewing it's GOST certification. Please contact your sales engineer for pricing on EAC.
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
IP42Ingress Protection: IP42 to IEC60529:2001 Protection against granular foreign bodies - Protected against direct sprays up to 15o from the vertical Optional
User-added image
Korea KET KC Mark GTM21097-5012 HU10040-7022B (12V Only)
User-added imageJAPAN TUV Rheinland-PSE GlobTek Inc to J60950-1(H26) , J55022(H22),J3000(H25).Please follow the procedure listed in the following link for proper import to Japan: http://en.globtek.com/importing-to-japan.php.
RoHS 2RoHS 2: Complies with EU 2011/65/EU and CHINA SJ/T 11363-2006 http://www.ce-mark.com/Rohs%20final.pdf
User-added image
Serial Number Information
User-added image
IEC/EN60601-1
SIQ Mark License EN60601-1, 3rd edition
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products
SKUVolts OutCurrent Out (Amps)Connector
19955027.80.8Female Barrel 5.5*2.1*11mm WITH internal Spring Clip and Locking Notch or Equal

Request Info

Text us your inquiry