Information | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Model Number | GT-F6100-10VV-FW | ||||||||||||||||
Description | GT-F6100-10VV-FW, Single Output Power supply, Open Frame/Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, Molex 26-60-4030 3 Position Header Pin 1: Line, Pin 2: Removed, PIN 3: Neutral, Output Rating: 10 Watts, Power rating with convection cooling (W) , 5-48V in 0.1V increments, Approvals: EAC; | ||||||||||||||||
Agency Documents | |||||||||||||||||
CE EC-Declaration for Medical | Contact GlobTek for more information | ||||||||||||||||
CE EC-Declaration for Industrial/Commercial/ITE | https://globtek.secure.force.com/models/ec_declaration?id=a0O0c00000PGM1zEAH | ||||||||||||||||
CE EC-Declaration for Household | Contact GlobTek for more information | ||||||||||||||||
UKCA-Declaration for Medical | Contact GlobTek for more information | ||||||||||||||||
UKCA-Declaration for Industrial/Commercial/ITE | https://globtek.secure.force.com/models/ukca_declaration?id=a0O0c00000PGM1zEAH | ||||||||||||||||
UKCA-Declaration for Household | Contact GlobTek for more information | ||||||||||||||||
Morocco SDoC Declaration | https://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0O0c00000PGM1zEAH | ||||||||||||||||
RoHS/RoHS3 Declaration | https://www.globtek.com/pdf/rohs_cert/a0O0c00000PGM1zEAH | ||||||||||||||||
Prop 65 Statement | https://en.globtek.com/prop-65-statement.pdf | ||||||||||||||||
REACH Declaration | https://www.globtek.com/pdf/iso_certificates/REACH.pdf | ||||||||||||||||
Conflict Minerals Declaration | https://www.globtek.com/pdf/conflict-minerals.pdf | ||||||||||||||||
Model Parameters | |||||||||||||||||
Type | Open Frame/Internal | ||||||||||||||||
Technology | Regulated Switchmode AC-DC Power Supply AC Adaptor | ||||||||||||||||
Category | Single Output Power supply | ||||||||||||||||
Input Voltage Range (V) | 100-240V~, 50-60 Hz | ||||||||||||||||
Max Input Current (A) | 0.3 A | ||||||||||||||||
Max Output Power Rating (W) | 10 | ||||||||||||||||
Output Voltage Range (V) | 5-48 | ||||||||||||||||
Efficiency | N/A | ||||||||||||||||
Ingress Protection | N/A | ||||||||||||||||
Size (mm) | 40mm x 68mm | ||||||||||||||||
Enclosure | |||||||||||||||||
Rating Table | |||||||||||||||||
* (Final ordering #/Part No to be defined)
| |||||||||||||||||
Specifications | |||||||||||||||||
A) ELECTRICAL SPECIFICATIONS: 01. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac 02 .Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz 03. Output Regulation: +/- 5% measured at the output connector 04. Line Voltage Regulation: +/- 1% typical measures at full load 05. Output Ripple (Vp-p): 1% or 150 mV whichever is greater measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with 10 uf electrolytic capacitor connected at the end of output connector at nominal line 06. Turn-On/Turn-Off Overshoot: 5% maximum, 1mS typical recovery time for 25% step load 07. Turn-On Delay: 3 second typical 08. Hold-Up Time: 8mS typical @ nominal input voltage & full load 09. Inrush Current: 30A typical @ 115Vac input ; 60A typical @ 230Vac input 10. Switching Frequency: 66.5 KHz typical B) PROTECTION 1. Over-Voltage: Protected via zener diode across the output 2. Short Circuit: Electronically Protected, unit will recover upon removal of fault 3. Input Protection: Input dual-fusing (for both line and neutral) C) SAFETY 1. Dielectric Withstand Voltage: 5656 VDC from primary to secondary 2. Earth Leakage Current: N/A for Class II units, there is no PE Ground pin, so Earth Leakage current is not measured 3. Touch Current: Maximum allowed values: 100uA NC(Normal condition) 500uA SFC(single fault condition) 4. If Class 1 input is available, then simply attach the earth connection to the output system ground point. No earth connection is required at the power supply PCB. 5. Means of Protection: 2 x MOPP (Means Of Patient Protection) D) OTHER: 1. MTBF: 200,000 hours @ 25°C ambient temperature 2. Operating Temperature: -10°C to 40°C ambient temperature, Convection Cooled. Higher ambient temperatures available with forced air cooling. 3. Humidity: 0% to 93% relative humidity, passed 7 day humidity testing per IEC 60601-1 4. Storage Temperature: -10°C to 80°C 5. RoHS 2: Complies with EU 2011/65/EU and China SJ/T 11363-2006 E) OPEN FRAME 01. Markings: Label | |||||||||||||||||
Derating Curve | |||||||||||||||||
Qty (ea.)/Carton | 124 | ||||||||||||||||
Individual Box/Gift Box Size (mm) | 95*65*35 | ||||||||||||||||
Individual Box/Gift Box Color | White | ||||||||||||||||
Master Carton Size (mm) | 442 x 330 x 275 | ||||||||||||||||
Gross Weight (kg) | 15.2 | ||||||||||||||||
Label Width (mm) | 25.0 | ||||||||||||||||
Label Height (mm) | 17.0 | ||||||||||||||||
Input Configuration | |||||||||||||||||
Description | Molex 26-60-4030 3 Position Header Pin 1: Line, Pin 2: Removed, PIN 3: Neutral Optional Input Wiring Kits are available:
| ||||||||||||||||
Approvals | |||||||||||||||||
| |||||||||||||||||
Popular Products (Stock items) | |||||||||||||||||
| |||||||||||||||||
News Releases | |||||||||||||||||
|
What is an open frame or internal AC-DC Power supply?
Open frame AC-DC power supplies are also known as AC-DC converters and are a type of internal power supply. The open frame AC to DC power supply is built into the inside of a system and used to convert the AC current into DC voltage.
How Does an AC-DC Adapter Work?
The AC to DC adapter or external power supply consists of a power supply which is enclosed in a housing similar to an AC plug, hence the term plug type, wall plug in, plug-in or plugtop power adapter. The power supply is plugged into the mains socket and the AC Voltage is then converted by the AC to DC adapter power supply into a DC voltage that is fed into the appliance via the output cable connection.