Request Information Download PDF Configure Output Connector
GT-41062-WWVV-T3A GT-41062-WWVV-T3A
Information
Model NumberGT-41062-WWVV-T3A
DescriptionGT-41062-WWVV-T3A, ITE Power Supply, Desktop/External, Regulated Switchmode AC-DC, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C6 AC Inlet Connector, Class I, Earth Ground ( aka "Mickey Mouse"), Output Rating: 18 Watts, 5-24V in 0.1V increments, Approvals: C-Tick CB CCC CE China RoHS Class I cULus GOST-R IP40 WEEE VCCI Ukraine LPS Level IV NrCAN RoHS 2 PSE SIQ Level V IRAM PSE PSE
Agency Documentshttp://www.globtek.info/certs/GT-41062-T2-T3-T3A/
CE EC-Declaration for MedicalContact GlobTek for more information
CE EC-Declaration for Industrial/Commercial/ITEhttp://globtek.force.com/models/ec_declaration?id=a0Oa000000BzyEDEAZ
RoHS/RoHS2 Declarationhttp://www.globtek.com/pdf/rohs_cert/a0Oa000000BzyEDEAZ
REACH Declarationhttp://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttp://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeDesktop/External
TechnologyRegulated Switchmode AC-DC
CategoryITE Power Supply
Input Voltage100-240V~, 50-60 Hz
I/P Amps (A)0.6 A
Wattage (W)18
Vout Range (V)5-24
EfficiencyIV
Ingress Protection
Size (mm)74*44*34
EnclosureUser-added image
Rating Table
Model NumberVoltageAmps (A)Watts (W)RFQ
GT-41062-1805-T3A53.618RFQ
GT-41062-1806-T3A6318RFQ
GT-41062-1807-T3A72.5717.99RFQ
GT-41062-1809-T3A9218RFQ
GT-41062-1812-T3A121.518RFQ
GT-41062-1815-T3A151.218RFQ
GT-41062-1818-T3A18118RFQ
GT-41062-1820-T3A200.918RFQ
GT-41062-1824-T3A240.7518RFQ
SpecificationsA) ELECTRICAL SPECIFICATIONS:
1. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac
2. Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz
3. Output Power (Rated): 18Watts max
4. Output Regulation: +/- 5% measured at the output connector
5. Line Voltage Regulation: +/- 1% typical measures at full load
6. Output Ripple (Vp-p): 1% or 150 mV whichever is greater measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with 10 uf electrolytic capacitor connected at the end of output connector at nominal line
7. Turn-On/Turn-Off Overshoot: 5% maximum, 1mS typical recovery time for 25% step load
8. Turn-On Delay: 1 second typical
09. Hold-Up Time: 8mS typical @ nominal input voltage & full load
10. Inrush Current: 30A typical @ 115Vac input ; 60A typical @ 230Vac input
11. Switching Frequency: 65 KHz typical

B) PROTECTION
1. Over-Voltage: Protected via zener diode across the output
2. Short Circuit: Electronically Protected, unit will recover upon removal of fault
3. Input Protection: Input line fusing

C) SAFETY
1. Dielectric Withstand Voltage: 4242Vdc from primary to secondary
2. Touch Current: <0.25mA @ 240Vac input voltage
3. Earth Leakage Current: <3.5mA @ 240Vac input voltage
4. ROHS 2: Complies with EU 2011/65/EU and China SJ/T 11363-2006
4. Earth continuity test:<0.1 Ohm or < 0.2 Ohm when with a non-detachable Power Supply cord, Class I Only


D) OTHER:
1. MTBF: 200,000 hours @ 25°C ambient temperature
2. Operating Temperature: 0°C to 40°C ambient temperature
3. Humidity: 0% to 90% relative humidity
4. Storage Temperature: -10°C to 80°C

E) ENCLOSURE
1. Upper Housing: High impact plastic, 94V0 polycarbonate, non-vented
2. Lower Housing: High impact plastic, 94V0 polycarbonate, non-vented
3. Size: 80.5* 50.0*31.0 mm +/-1.0
Derating Curve
Qty (ea.)/Carton80
Individual Box/Gift Box Size (mm)57*110*70
Individual Box/Gift Box ColorWhite
Master Carton Size (mm)450 x 295 x 285
Gross Weight (kg)15.6
Label Width (mm)39.6
Label Height (mm)59.6
Input Configuration
DescriptionIEC 60320/C6 AC Inlet Connector, Class I, Earth Ground ( aka "Mickey Mouse")User-added image

Mates with IEC 60320/C5 Plug

 
 Standard International IEC 320/C Cordsets

Below are standard cordsets which are "not included" (unless stated above); these can be purchased separately or package with the power supply. Contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material.

3021066F712(R)

N. American

NEMA 5-15P

IEC 320/C5

1880

6

1191068F0712(R)

N. American

NEMA 5-15P Hospital

IEC 320/C5

2459

8

2064262M0712(R)

Australian

AS3112 / 3 PRONG

IEC 320/C5

2050

7

204B4262M0712(R)

Brazil

BRAZILIAN; WS-002

IEC 320/C5

2050

7

6023592M5712(R)

China

CCC GR2099

IEC 320/C5

2500

8

23144262M0712(R)

Europe

CEE 7/7

IEC 320/C5

2050

7

2084262M0712(R)

India/S.Africa

India/S.Africa

IEC 320/C5

2050

7

23024262M0712(R)

Italy

CEI 23-16/VII

IEC 320/C5

2050

7

3003316F0712(R)

Japan

JIS 8303 / 3 PINS

IEC 320/C5

1830

6

23214262M0712(R)

Switzerland

SEV 1011 ( EL 203)

IEC 320/C5

2050

7

6104262M0712(R)

UK

BS1363

IEC 320/C5

2050

7

Output Configuration
Common output connector options:
Click to add to your request.






L Type (Coaxial 5.5x2.5mm plug) C Type (Coaxial 5.5x2.1mm plug) K Type (Coaxial 3.5x1.3mm plug) LL Type (5.5x2.5mm Locking 760k type) CL Type (5.5x2.1mm Locking S761k type) Magnetic Connector






YL3 Type (KPPX-3P) YL4 Type (KPPX-4P) EJ1/2/3/4/5 (EIAJ RC-5320A type connectors) MSB Type (Micro USB) USBC Type (USB Type C) Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals
LogoDescription
C-Tick GT-41062 N4292 SAA111044EA
C-Tick GT-41062 N4292 SAA111044EA
No Logo CB Certificate IEC 60950-1:2005 (2nd Edition), Am 1: 2009, CB report IEC 60950-1:2005 (2nd Edition), Am 1: 2009 and EN 60950-1:2006 + Am 1:2010 + Am 11:2009 + Am 12:2011
User-added imageCCC to GB4943.1-2011 GB9254-2008 GB17625.1-2012, Tropical <2000
User-added image  CE Mark: tested to comply with EN55022:2006/A1:2007 Class B, EN610003-2, EN610003-3 including EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6N EN61000-4-11; EMI: Complies with EN55011 CLASS B and FCC Part 15B - On label or Molded in case
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
User-added image
Class I Earth Ground
User-added image
UL60950-1, cULus to UL 60950-1, 2nd Edition, 2007-03-27 and CSA C22.2 No. 60950-1-07, 2nd Edition, 2007-03
User-added image
 
GOST-R mark for Russia(Document: http://www.globtek.com/html/iso_certificates/GT_GOST-R.pdf). 03/15/2015. Due to lack of demand, GlobTek will not be renewing it's GOST certification. Please contact your sales engineer for pricing on EAC.
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
IP40Ingress Protection: IP40 to IEC60529:2001 Protection against granular foreign bodies
User-added imageIRAM certificate DC-E-G71-001.1 to IEC 60950 + A1:2009
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50314327, to J60950-1(H26) , J55022(H22),J3000(H25)[15V or less]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50314327, to J60950-1(H26) , J55022(H22),J3000(H25)[DC15≤30V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageEfficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
User-added image

Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)... NOTE: 24V & 1830 mm 18 - 20awg o/p cord only
LPSLimited Power Source
User-added imageEEV1191Natural Resources Canada (NRCan): CSA Standard C381.1-08, QSP NRCAN EEV1191; http://shop.csa.ca/en/canada/energy-efficiency/cancsa-c3811-08/invt/27024802008
User-added imageJAPAN TUV Rheinland-PSE GlobTek Inc to J60950-1(H26) , J55022(H22),J3000(H25).Please follow the procedure listed in the following link for proper import to Japan: http://en.globtek.com/importing-to-japan.php.
RoHS 2RoHS 2: Complies with EU 2011/65/EU and CHINA SJ/T 11363-2006 http://www.ce-mark.com/Rohs%20final.pdf
User-added image
IEC/EN60950-1
SIQ Mark License Certificate EN 60950-1:2006 + Am 1:2010+ Am 11:2009 + Am 12:2011
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products
SKUVolts OutCurrent Out (Amps)Connector
165790240.75Socket for interchangeable o/p connectors
16579153.6Socket for interchangeable o/p connectors
13673253.6Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal

Request Info