Model NumberGTM91099-60VV-FW
DescriptionGTM91099-60VV-FW, ITE / Medical Power Supply, 60601-1-4th Ed. , Open Frame/Internal, Regulated Switchmode AC-DC, , Input Rating: 100-240V~, 50-60 Hz, Molex 09-65-2038 3 Position Header Pin 1: Neutral, Pin 2: Removed, Pin 3: Line, Output Rating: 60 Watts, 5-48V in 0.1V increments, Approvals: CE Double Insulation RoHS 2 Ukraine cUR VCCI WEEE cRUus China RoHS CB 60601-1 2MOPP Level V CB CE NEMKO ETL CE S-Mark IEC/EN 60601-1 EAC NEMKO IP42
Agency Documentshttp://www.globtek.info/certs/GTM91099/
CE EC-Declaration for Medicalhttp://globtek.force.com/models/ec_declaration?id=a0Oa000000C2pYVEAZ
CE EC-Declaration for Industrial/Commercial/ITEhttp://globtek.force.com/models/ec_declaration?id=a0Oa000000C2pYVEAZ
RoHS/RoHS2 Declarationhttp://www.globtek.com/pdf/rohs_cert/a0Oa000000C2pYVEAZ
REACH Declarationhttp://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttp://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeOpen Frame/Internal
TechnologyRegulated Switchmode AC-DC
CategoryITE / Medical Power Supply
Input Voltage100-240V~, 50-60 Hz
I/P Amps (A)1.5 A
Wattage (W)60
Vout Range (V)5-48
EfficiencyV
Ingress Protection
Size (mm)125*75*38
EnclosureUser-added image
Rating Table
Model NumberVoltageAmps (A)Watts (W)RFQ
GTM91099-3009-4.0-FW5630RFQ
GTM91099-4509-FW9545RFQ
GTM91099-6015-3.0-FW12560RFQ
GTM91099-6015-FW15460RFQ
GTM91099-6024-FW242.560RFQ
GTM91099-6048-FW481.2560RFQ
SpecificationsA) ELECTRICAL SPECIFICATIONS:
01. Input Voltage: Specified 90-264 Vac, Nameplate rated 100-240 Vac
02. Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60 Hz
03. Output Regulation: +/- 5% measured at the output connector
04. Line Voltage Regulation: +/- 2% typical measured at full load
05. Output Ripple (Vp-p): +/-1% or 150mV whichever is greather at nominal output voltage. Measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with 10 uf electrolytic capacitor connected at the end of the output connector at nominal line
06. Turn-ON/OFF Overshoot: 5% maximum, 500uS typical recovery time for 25% to 50% step load
07. Turn-ON Delay: 2 Seconds, maximum @ full load, nominal line
08. Hold-Up Time: 8 mS typical @ nominal input voltage and full load
09. Inrush Current: 40/60A maximum cold start @ 115/230Vac input
10. Switching Frequency: 100 KHz typical

B) PROTECTION
1. Over-Voltage: Protected with a Zener diode clamp across the output
2. Short Circuit: Hiccup with auto recovery
3. Over-load: Hiccup with auto recovery
4. Input Protection: Input line and neutral fusing
5. Means of Patient Protection: (2 x MOPP)

C) SAFETY
01. Dielectric Withstand Voltage: 5656Vdc from primary to secondary
02. Earth Leakage Current: N/A for Class II units, there is no PE Ground pin, so Earth Leakage current is not measured
03. Touch Current: Maximum allowed values: 100uA NC(Normal condition) 500uA SFC(single fault condition)
04. ROHS 2: Complies with EU 2011/65/EU and China SJ/T 11363-2006

D) OTHER:
1. MTBF: 200,000 Hours @ 25°C ambient temperature
2. Operating Temperature: 0°C to 40°C ambient temperature
3. Humidity: 0% to 90% relative humidity
4. Storage Temperature: -10°C to 80°C
5. Cooling: Convection

E) ENCLOSURE
1. Open Frame
2. Size: 122*63.5*34 +/-1.0 mm
3. LED: Standard Green color to indicate power out (other colors available)
Derating CurveUser-added image
Qty (ea.)/Carton30
Individual Box/Gift Box Size (mm)Cell Packaging
Individual Box/Gift Box ColorN/A
Master Carton Size (mm)475*475*120
Gross Weight (kg)
Label Width (mm)80.0
Label Height (mm)7.5
Input Configuration
DescriptionMolex 09-65-2038 3 Position Header Pin 1: Neutral, Pin 2: Removed, Pin 3: LineDocument: http://www.molex.com/pdm_docs/sd/009652038_sd.pdf
Catalog Page: http://www.molex.com/molex/products/datasheet.jsp?part=active/0009652038_PCB_HEADERS.xml

User-added image
 

Mates With Part(s):

5195 SPOX™ Crimp Housing, 5239 KK® Crimp Housing

Approvals
LogoDescription
User-added imageAttention Mark / Refer to operating manual for operating and service instructions
User-added image60601-1 3rd Operating Instructions
No Logo ApplicableCB report IEC 60601-1: 2005 + CORR. 1 (2006) + CORR. 2 (2007) and or EN 60601-1:2006 3rd Edition 2xMOPP
No Logo CB Certificate IEC 60950-1:2005 (2nd Edition), Am 1: 2009, CB report IEC 60950-1:2005 (2nd Edition), Am 1: 2009 and EN 60950-1:2006 + Am 1:2010 + Am 11:2009 + Am 12:2011
User-added image  CE Certification CE Mark: tested to comply with EN 55032.2012+AC.2013 EN 61000-3-2.2014 EN 61000-3-3.2013 EN 60601-1-2.2015 EN 55024.2010
User-added image  CE Mark: tested to comply with EN55022:2006/A1:2007 Class B, EN610003-2, EN610003-3 including EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6N EN61000-4-11; EMI: Complies with EN55011 CLASS B and FCC Part 15B - On label or Molded in case
User-added image  CE Mark: tested to comply with EN61000-3-2, EN61000-3-3 and EN50082-1, including EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61001-1-2-2007 EMI: Complies with EN55011 CLASS B and FCC Part 15 B
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
User-added imagecRUus UL Recognized Component E341350 3rd Edition w-RM ANSI-AAMI ES60601-1 (2005 + C1:09 + A2:10) and CAN-CSA-C22.2 No. 60601-1 (2008)
User-added image

Double Insulation - Mark is on the label or Molded in the case
User-added image  Certification # TC RU C-US.AR46.B.79113 Custom Union of Russia, Belarus and Kazakhstan
User-added imageMedical Electrical Equipment – Part 1: General Requirement for Basic safety Essential Performance (AAMI ES60601-1:2005+A1) Medical Electrical Equipment – Part 1: General Requirement for Basic safety Essential Performance (CSA C22 2#60601-1:2014 Ed.3)
User-added image
IEC/EN60601-1
User-added image
IEC/EN60950-1
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
IP42Ingress Protection: IP42 to IEC60529:2001 Protection against granular foreign bodies - Protected against direct sprays up to 15o from the vertical Optional
 User-added image

Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
User-added imageNemko Mark Certificate EN 60601-1:2006 3rd Edition
User-added imageNEMKO EN60950-1:2006, A11, A1, A12, A2
RoHS 2RoHS 2: Complies with EU 2011/65/EU and CHINA SJ/T 11363-2006 http://www.ce-mark.com/Rohs%20final.pdf
User-added imageSemko S-Mark-Cert-EN60601-1 and EN60950-1
User-added image
Serial Number Information
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
UL cRUus Registered E341350
UL cRUus Registered E341350
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products
SKUVolts OutCurrent Out (Amps)Connector
144417125.0P/N: 09-65-2028, KK® 3.96mm Crimp Terminal Housing, Friction Ramp, 2 Circuits or equivalent
180411144P/N: 09-65-2028, KK® 3.96mm Crimp Terminal Housing, Friction Ramp, 2 Circuits or equivalent
169820154P/N: 09-50-3041, KK® 3.96mm Crimp Terminal Housing, Friction Ramp, 4 Circuits or equivalent
177811154P/N: 09-50-3041, KK® 3.96mm Crimp Terminal Housing, Friction Ramp, 4 Circuits or equivalent
176483242.5None
18070556P/N: 09-65-2028, KK® 3.96mm Crimp Terminal Housing, Friction Ramp, 2 Circuits or equivalent
169820154P/N: 09-50-3041, KK® 3.96mm Crimp Terminal Housing, Friction Ramp, 4 Circuits or equivalent

Request Info